{"id":21961,"date":"2026-11-02T14:20:00","date_gmt":"2026-11-02T13:20:00","guid":{"rendered":"https:\/\/webhosting.de\/?p=21961"},"modified":"2026-10-30T12:49:30","modified_gmt":"2026-10-30T11:49:30","slug":"smartnics-inden-for-hosting-og-netvaerksacceleration","status":"publish","type":"post","link":"https:\/\/webhosting.de\/da\/smartnics-im-hosting-netzwerkbeschleunigung\/","title":{"rendered":"SmartNIC'er i hosting: S\u00e5dan vurderer man netv\u00e6rksacceleration korrekt"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">SmartNIC\u2019er er ikke en fordel inden for hosting p\u00e5 grund af h\u00f8je porthastigheder, men n\u00e5r en optaget <strong style=\"font-weight:700;color:inherit\">CPU-flaskehals i netv\u00e6rksdatavejen<\/strong> som f\u00f8lge af tilbagevendende regler, overlays, virtuelle switche eller kryptering. Det afg\u00f8rende er, om kort, firmware, drivere og platform rent faktisk fuldt ud afspejler de n\u00f8dvendige match og handlinger i hardwaren. Ellers forbliver en del af behandlingen i v\u00e6rten. F\u00f8r en anskaffelse skal kompatibilitetskontrol, flow-dokumentation, fallback-sti og livscyklusomkostninger derfor indg\u00e5 i den samme beslutning.  <\/p>\n<nav class=\"wh-toc\" aria-label=\"Indholdet af denne artikel\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">G\u00e5 direkte til afsnittet<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#smartnic-grundlagen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">S\u00e5dan placeres SmartNIC'er korrekt i hosting-l\u00f8sninger<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#datenpfad-und-offload\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Hvordan hardware-offload \u00e6ndrer datavejen<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#geeignete-hosting-szenarien\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Hvor SmartNIC\u2019er er en fordel inden for hosting<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#eignung-nach-einsatzfall\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Teknisk sammenligning af anvendelsestilf\u00e6lde<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#integration-und-kompatibilitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Kontroller kompatibiliteten inden udrulningen<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#alternativen-und-kapazitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Afveje SmartNIC mod CPU og software<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#betrieb-und-monitoring\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">G\u00f8re offload synlig under drift<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#fehlerbilder-und-rueckfall\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Typiske fejlm\u00f8nstre og tilbagefaldsforl\u00f8b<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#entscheidungsrahmen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Tr\u00e6ffe realistiske beslutninger om indk\u00f8b og drift<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"smartnic-grundlagen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"smartnic-grundlagen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">S\u00e5dan placeres SmartNIC'er korrekt i hosting-l\u00f8sninger<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Begrebet <strong style=\"font-weight:700;color:inherit\">SmartNIC<\/strong> er ikke et ensartet standardiseret produktnavn. Ved planl\u00e6gningen af hosting er det derfor ikke betegnelsen, der er afg\u00f8rende, men den p\u00e5viselige funktion i datavejen: Hvilke pakker, regler og tunneler kan kortet h\u00e5ndtere, hvilke opgaver forbliver hos v\u00e6rten, og hvilken software styrer funktionerne? En h\u00f8j porthastighed giver ikke svar p\u00e5 disse sp\u00f8rgsm\u00e5l.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Et klassisk netv\u00e6rkskort leverer f\u00f8rst og fremmest Ethernet-forbindelsen og underst\u00f8tter almindelige grundl\u00e6ggende offload-funktioner, s\u00e5som kontrolsummer eller segmentering. Et <strong style=\"font-weight:700;color:inherit\">SmartNIC<\/strong> udvider denne ramme med specialiserede eller programmerbare datavejsfunktioner. Dette kan omfatte flow-regler, virtuelle switching-funktioner, SR-IOV, tunnelbehandling eller kryptografiske delopgaver. Om disse funktioner kan benyttes, afh\u00e6nger dog af en kombination af model, firmware, drivere og platformintegration.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En <strong style=\"font-weight:700;color:inherit\">DPU<\/strong> er som regel mere omfattende opbygget: Ud over netv\u00e6rks-ASIC\u2019en har den egne beregningsressourcer og kan drive en separat infrastruktur-datavej. NVIDIA beskriver for BlueField en DPU-tilstand, hvor det integrerede Arm-system styrer NIC-ressourcer og datavejen, samt en NIC-tilstand, hvor kortet fungerer som en adapter over for den eksterne v\u00e6rt.  Dette skaber dermed, afh\u00e6ngigt af driftstilstanden, ogs\u00e5 et eget administrations- og tillidsomr\u00e5de.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Denne klassificering har praktiske konsekvenser for indk\u00f8b og drift. Et kort med egen beregningslogik er ikke automatisk det bedste valg, hvis der kun er behov for enkle, grundl\u00e6ggende offloads. Omvendt kan en udlagret infrastrukturvej v\u00e6re fornuftig med henblik p\u00e5 klientadskillelse eller sikkerhedsfunktioner, men kr\u00e6ver i s\u00e5 fald firmwarevedligeholdelse, adgangskoncepter, overv\u00e5gning og gendannelsesprocesser for yderligere komponenter.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Selv en 100-GbE-port eller en hurtigere port medf\u00f8rer ingen hastighedsfor\u00f8gelse for firewall-regler, overlays eller kryptering. Det afg\u00f8rende er pakkest\u00f8rrelse, antallet af parallelle flows, regelomfanget og sp\u00f8rgsm\u00e5let om, hvorvidt de n\u00f8dvendige handlinger rent faktisk kan implementeres i hardware. F\u00f8rst n\u00e5r det kan p\u00e5vises, at server-CPU\u2019en udg\u00f8r en begr\u00e6nsning i netv\u00e6rksdatavejen, bliver en liste over funktioner til en mulig kapacitetsgevinst.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"datenpfad-und-offload\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"datenpfad-und-offload\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Hvordan hardware-offload \u00e6ndrer datavejen<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Uden yderligere offload n\u00e5r en pakke f\u00f8rst frem til det fysiske netv\u00e6rkskort og behandles derefter af v\u00e6rten. Afh\u00e6ngigt af arkitekturen passerer den gennem kernelens netv\u00e6rksstack, firewall, bridge eller virtuel switch, routing og eventuelt indkapsling til et overlay. F\u00f8rst derefter n\u00e5r den en VM, en container eller en anden fysisk port. Hvert trin kan medf\u00f8re CPU-tid og k\u00f8er.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Denne fremgangsm\u00e5de bliver is\u00e6r relevant, n\u00e5r der er tale om mange sm\u00e5 pakker, et stort antal kortvarige forbindelser eller omfattende klientpolitikker. Det er ikke kun den overf\u00f8rte datam\u00e6ngde, der belaster v\u00e6rten, men ogs\u00e5 den gentagne behandling af enkelte pakker og datastr\u00f8mme. Derfor er <strong style=\"font-weight:700;color:inherit\">netv\u00e6rksacceleration<\/strong> ikke en generel egenskab ved en server, men en m\u00e5lrettet aflastning af en konkret identificeret datavej.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">P\u00e5 <strong style=\"font-weight:700;color:inherit\">Hardware-aflastning<\/strong> kan styringskomponenter overf\u00f8re tilladte videresendelses- og filterregler til en hardwaredatavej. Linux-switchdev-modellen beskriver i denne sammenh\u00e6ng flytningen af videresendelsesdatastien fra kernen til en switch. Hvilke regler der rent faktisk overtages, afh\u00e6nger af det konkrete kort, dets driver og den overliggende netv\u00e6rksintegration. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">OVS-dokumentationen i udviklingsgrenen 4.0.90 beskriver udtrykkeligt et s\u00e6rskilt afsnit om Flow Hardware Offload som eksperimentelt. Netop for denne OVS-med-DPDK-konfiguration skelner den mellem fuldst\u00e6ndig offload af matches og handlinger samt delvis offload, hvor kun matches udlades. Denne beskrivelse udg\u00f8r ikke et stabilt, generelt gyldigt kompatibilitetsbevis for andre OVS-versioner, NIC'er eller platforme. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I praksis skal enhver offload-angivelse derfor specificere den konkrete datavej: den anvendte softwareversion, drivere, firmware, match-felter og handlinger. En aktiveret kontakt beviser hverken, at relevante datastr\u00f8mme er udlagt, eller at sikkerheds- og netv\u00e6rkssemantikken fortsat opfyldes u\u00e6ndret. Ved VLAN-filtrering kr\u00e6ver switchdev for eksempel, at hardwaren overholder Bridge-VLAN-reglerne og afviser ikke-godkendte VLAN-ID'er.  Offload er dermed den tekniske implementering af eksisterende regler, ikke en omvej uden om dem.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"geeignete-hosting-szenarien\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"geeignete-hosting-szenarien\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Hvor SmartNIC\u2019er er en fordel inden for hosting<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">SmartNIC\u2019er er is\u00e6r velegnede p\u00e5 virtualiseringsplatforme med mange VM\u2019er og gentagne videresendelsesbeslutninger. SR-IOV kan tildele en VM en virtuel funktion; i en switchdev-arkitektur afspejler representor-gr\u00e6nseflader fysiske eller virtuelle funktioner i operativsystemet. Regler for trafikken mellem disse porte kan dermed implementeres i hardwaren.   Fordelen afh\u00e6nger dog af de n\u00f8dvendige VM-funktioner.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Overlay-netv\u00e6rk med klientunderst\u00f8ttelse og <strong style=\"font-weight:700;color:inherit\">Mikrosegmentering<\/strong> er et yderligere udgangspunkt. Hvis mange kundenetv\u00e6rk gentagne gange anvender VLAN- eller overlay-tildelinger, adgangskontrolregler og lignende flow-beslutninger, kan en passende hardwaredatavej aflaste v\u00e6rts-CPU\u2019erne. Foruds\u00e6tningen er dog stadig, at antallet af regler, matchfelter og handlinger er tilg\u00e6ngelige i det valgte kort samt i driveren, og at politikens semantik bevares fuldt ud.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For OpenShift Container Platform 4.22 dokumenterer Red Hat hardware-offload for bare-metal-noder med kompatibelt SmartNIC og aktiv SR-IOV Network Operator. Her underst\u00f8ttes kun pod-til-pod-kommunikation samt pod-til-ClusterIP-tjeneste med almindelige pods; DPDK-applikationer er ikke kompatible med denne funktion. Fordelen er desuden begr\u00e6nset til kommunikationsstr\u00e6kninger, hvor de involverede noder anvender kompatible SmartNIC'er. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I krypterede v\u00e6rts- eller lokalnetv\u00e6rk kan IPsec-offload overtage delopgaver eller hele processen med indkapsling, udpakning, kryptering og beskyttelse mod replay-angreb. NVIDIA dokumenterer forskellige former for offload i denne sammenh\u00e6ng, herunder Crypto- og Full-Offload.  Dette betyder dog ikke, at de er universelt anvendelige: Underst\u00f8ttelse og ydeevnebegr\u00e6nsninger afh\u00e6nger af model, firmware og kryptografisk metode.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En simpel webhostingserver er bevidst valgt som et modeksempel. Hvis den hovedsageligt leverer f\u00e5, st\u00f8rre HTTP-svar og ikke viser nogen CPU-belastning i pakkestien, kan mere specialiseret <strong style=\"font-weight:700;color:inherit\">serverhardware<\/strong> skaber blot yderligere driftsomkostninger. F\u00f8rst b\u00f8r det afklares, om \u00e5rsagen til flaskehalsen ligger i applikationen, databasen, lageret eller netv\u00e6rket. SmartNIC\u2019er er ikke en god erstatning for denne diagnose.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"eignung-nach-einsatzfall\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"eignung-nach-einsatzfall\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Teknisk sammenligning af anvendelsestilf\u00e6lde<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Det er ikke den nominelle porthastighed, der afg\u00f8r, om et SmartNIC er en god id\u00e9, men derimod den konkrete datavej. Det er is\u00e6r en fornuftig l\u00f8sning, n\u00e5r mange tilbagevendende regler, h\u00f8je flow-tal eller overlay- og sikkerhedsfunktioner konstant belaster v\u00e6rts-CPU\u2019en. Fordelen er stadig <strong style=\"font-weight:700;color:inherit\">stiafh\u00e6ngig<\/strong>: Et afsnit med h\u00f8jere hastighed hj\u00e6lper kun de forbindelser, der rent faktisk k\u00f8rer via kompatibel hardware og underst\u00f8ttede regler. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Egnethed af SmartNIC-offload afh\u00e6ngigt af hosting-anvendelsesscenariet\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Egnethed af SmartNIC-offload afh\u00e6ngigt af hosting-anvendelsesscenariet<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Brugssag<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Mulig fordel<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Tekniske foruds\u00e6tninger<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Typisk begr\u00e6nsning<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Kontrolpunkt f\u00f8r udrulning<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">VM-hosting med SR-IOV<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Videresendelse mellem virtuelle funktioner kan foreg\u00e5 via eSwitch.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Passende kort, drivere og integration med Representor eller eSwitch.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">VM-netv\u00e6rksfunktioner og overv\u00e5gbarhed kan \u00e6ndre sig.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Test af underst\u00f8ttede VM-funktioner, sikkerhedsregler og migration.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">OpenShift 4.22 med OVN-Kubernetes<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">De dokumenterede Pod- og ClusterIP-servicestier kan udnytte hardware-offload.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Kompatible bare-metal-noder, SR-IOV-netv\u00e6rksoperat\u00f8r og passende pod-konfiguration.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Kun visse kommunikationstyper underst\u00f8ttes; DPDK-applikationer er ikke kompatible hermed.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Sammenlign underst\u00f8ttede pod-, service- og knudepunktsstier for platformversionen.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Overlay-netv\u00e6rk<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Tunnelbehandling og enkle videresendelsesregler kan reducere CPU-belastningen.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">St\u00f8tte til n\u00f8dvendige tunneler, kampe og aktioner.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Handlinger, der ikke underst\u00f8ttes, medf\u00f8rer delvis eller manglende offload.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Kontroller tunnelformat, regelomfang og tilbagefald i softwaren.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">IPsec<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Indkapsling, udpakning og kryptografiske opgaver kan udliciteres afh\u00e6ngigt af modellen.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Passende kortmodel, firmware og underst\u00f8ttet IPsec-offload-variant.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Funktioner og begr\u00e6nsninger afh\u00e6nger af generation og konfiguration.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Kontroller, om der foreligger dokumentation for krypto- eller fuld offload-funktion for m\u00e5lmodellen.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Programmerbar infrastrukturdatavej<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Der kan implementeres specialiseret flow-behandling til relevante funktioner.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Den n\u00f8dvendige integration af systemtilstand, styring og platform skal underst\u00f8ttes konkret.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">En producents funktionsbeskrivelse g\u00e6lder ikke for andre SmartNIC\u2019er.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Konkret afstemning af den n\u00f8dvendige match-, handlings- og tilstandssemantik.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Enkel webhostingserver<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">I bedste fald aflastning gennem s\u00e6dvanlige NIC-offloads.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Netv\u00e6rksdatastien er identificeret som en flaskehals.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Belastningen p\u00e5 applikationer, databaser eller lagringssystemer p\u00e5virkes ikke.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Registrer CPU- og netv\u00e6rksprofilen, inden der foretages en investering i hardware.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">N\u00e5r det g\u00e6lder VM-platforme, er <strong style=\"font-weight:700;color:inherit\">SR-IOV<\/strong> En typisk tilgang: Virtuelle funktioner tildeles en VM, mens Representor-gr\u00e6nseflader i operativsystemet afspejler porte for s\u00e5danne funktioner. P\u00e5 den m\u00e5de kan videresendelsesregler mellem virtuelle og fysiske porte i en switchdev-orienteret arkitektur implementeres i hardware. Dette erstatter dog ikke en kontrol af, om den \u00f8nskede klientadskillelse og driftsmodellen opretholdes. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Kubernetes er det modsatte af et generelt l\u00f8fte om hurtigere hastigheder. For den dokumenterede OpenShift 4.22-integration g\u00e6lder der bestemte underst\u00f8ttede trafikveje, kompatible SmartNIC-noder og krav til arbejdsbelastningen. Hvis en node med offload-funktion kommunikerer med en almindelig node, behandler denne almindelige node sin del i kernen og begr\u00e6nser dermed den samlede vej. En udrulning b\u00f8r derfor i f\u00f8rste omgang tage h\u00f8jde for en afgr\u00e6nset node-pool og reelle kommunikationsveje. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I forbindelse med krypterede v\u00e6rts- eller lokalnetv\u00e6rk skal disse begreber anvendes s\u00e6rdeles pr\u00e6cist. Dokumenterede IPsec-varianter sp\u00e6nder, afh\u00e6ngigt af platformen, fra \u00bbCrypto-Offload\u00ab til \u00bbFull Offload\u00ab for indkapsling, udpakning, kryptering og beskyttelse mod gentagelse. Dette medf\u00f8rer ingen generel garanti for gennemstr\u00f8mning: Model, firmware, anvendte algoritmer og produktrelaterede begr\u00e6nsninger bestemmer, hvilken behandling der faktisk udl\u00e6gges.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"integration-und-kompatibilitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"integration-und-kompatibilitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Kontroller kompatibiliteten inden udrulningen<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En anskaffelse begynder med en objektiv statusopg\u00f8relse, ikke med aktivering af offload-indstillinger. Registrer det n\u00f8jagtige kortmodel inklusive PCI-ID, firmwareversion, drivere og kerne. Derudover skal eSwitch-tilstand samt version og konfiguration af Open vSwitch, OVN, hypervisor eller Kubernetes-platformen v\u00e6re kendt, da kortets egenskaber alene ikke er tilstr\u00e6kkeligt bevis for fuldst\u00e6ndig softwareintegration.  <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-1024x683.webp\" class=\"wp-image-21965\" alt=\"En administrator tester et PCIe-netv\u00e6rkskort, inden det installeres i en server.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-genereret illustrativt billede til test af hardware og platform inden en offload-implementering.<\/figcaption><\/figure><div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"En kort kompatibilitetstest inden indf\u00f8relsen af offload\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">En kort kompatibilitetstest inden indf\u00f8relsen af offload<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Testniveau<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Oplysninger, der skal indsamles<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Hvorfor den er relevant<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Hardware<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Kortmodel, PCI-ID og portkonfiguration<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Fastl\u00e6gger ASIC-funktioner og tilg\u00e6ngelige virtuelle funktioner.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Firmware og drivere<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">N\u00f8jagtige versioner og underst\u00f8ttede kerner<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Kortet og v\u00e6rten skal have implementeringer, der passer sammen.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Datastibtilstand<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Konfiguration af eSwitch og switchdev<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Angiver, om regler kan overf\u00f8res til en hardware-switches datavej.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Virtuel switching<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">OVS-, OVN- eller hypervisor-version<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Bestemmer, hvilke funktioner softwaren kan anmode om for denne kombination.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Regelsemantik<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">N\u00f8dvendige protokoller, tunneler og handlinger<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Kun regler, der kan afbildes, kan k\u00f8re fuldst\u00e6ndigt i hardware.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Bevis og tilbagefald<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Flow-status, t\u00e6ller og software-fallback<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">G\u00f8r delvis offload og ikke-underst\u00f8ttede regler synlige under drift.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Den n\u00f8dvendige reguleringssemantik b\u00f8r foreligge p\u00e5 forh\u00e5nd som en beskrivelse af datastien: f.eks. VLAN-tildeling, IPv4 eller IPv6, TCP eller UDP, tunneltype, \u00e6ndring af header, videresendelse eller drop. Den eksperimentelle OVS 4.0.90-dokumentation viser for sin DPDK-konfiguration, at manglende hardwarehandlinger kan f\u00f8re til delvis offload. Heraf f\u00f8lger, at der for enhver anden version eller platform kun er tale om en opfordring til at unders\u00f8ge sagen, ikke en garanti for dens funktionsomfang. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Platformmatricer er <strong style=\"font-weight:700;color:inherit\">versionsafh\u00e6ngige kompatibilitetsattester<\/strong>, ingen generelle udsagn om en NIC-familie. OpenShift 4.22 angiver konkrete NIC\u2019er til sin hardware-offload-integration, herunder BlueField-2 i ConnectX-6-NIC-tilstand. Heraf kan man hverken udlede underst\u00f8ttelse af en anden firmware, en anden DPU-tilstand eller en afvigende distribution. Dokumenter derfor hver kombination af hardware, firmware, driver og platformversion separat. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For Linux-switchdev er det desuden afg\u00f8rende, at hardwaren overholder softwarenetv\u00e6rkets semantik. Ved VLAN-filtrering skal en switch, der udf\u00f8rer offload, for eksempel overholde broens VLAN-regler og afvise ikke-godkendte VLAN-ID'er. Dette krav viser, hvorfor funktionslister og sikkerhedspolitik skal kontrolleres i f\u00e6llesskab: Acceleration m\u00e5 ikke skabe en afvigende netv\u00e6rkssegmentering. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"alternativen-und-kapazitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"alternativen-und-kapazitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Afveje SmartNIC mod CPU og software<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En SmartNIC er blot \u00e9n af flere muligheder, n\u00e5r netv\u00e6rksbehandlingen er begr\u00e6nset. F\u00f8rst er det v\u00e6rd at unders\u00f8ge, om mere CPU-kapacitet, et passende antal k\u00f8er, RSS, IRQ-fordeling eller kernel-tuning allerede kan l\u00f8se flaskehalsen. For en oversigt over SoftIRQ'er, k\u00f8er og interrupt-fordeling henvises til artiklen om <a href=\"https:\/\/webhosting.de\/da\/softirq-cpu-hosting-optimering-af-netvaerksgennemstromning-datacenter\/\">CPU- og netv\u00e6rksgennemstr\u00f8mning i hosting<\/a> Yderligere grundl\u00e6ggende principper. Uden dokumentation for en netv\u00e6rksflaskehals forbliver yderligere specialhardware en antagelse.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">DPDK og AF_XDP kan forkorte softwarevejene p\u00e5 v\u00e6rts-CPU\u2019er, men kr\u00e6ver hver is\u00e6r en egen arkitektur- og CPU-planl\u00e6gning. Udsagnet om kontinuerlig polling kan ikke generelt overf\u00f8res til begge tilgange: I OVS-DPDK-dokumentationen for den beskrevne konfiguration poller en tr\u00e5d l\u00f8bende DPDK-enheder og optager derved en CPU-kerne fuldst\u00e6ndigt. NUMA-tildeling, kerneisolering og den konkrete OVS- og DPDK-version er derfor stadig en del af udformningen. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Selv et klassisk server-NIC kan levere tilstr\u00e6kkelig aflastning til kontrolsummer, segmentering eller enkelte tunnelfunktioner. Dette valg er passende, hvis der ikke er behov for omfattende virtuelle switch-regler, klientadskillelse eller sikkerhedsdataveje i hardware. SmartNIC'er bliver is\u00e6r en fornuftig l\u00f8sning, n\u00e5r de kr\u00e6vede funktioner g\u00e5r ud over s\u00e5danne grundl\u00e6ggende funktioner og er tilbagevendende p\u00e5 lang sigt.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Kapacitetsbegrebet er enkelt, men vigtigt: Hvis CPU-kerner p\u00e5 en host udnyttes fuldt ud til pakkebehandling, og en repr\u00e6sentativ del af disse pakker kan aflastes fuldst\u00e6ndigt, kan der muligvis opst\u00e5 CPU-reserver. Denne ledige kapacitet t\u00e6ller dog kun som brugbar kapacitet, hvis ikke applikationen, hukommelsen, lagringsmediet eller en software-fallback udg\u00f8r den n\u00e6ste flaskehals. Den er ikke en direkte afledning af linkhastighed eller kortpris.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Sammenlign derfor alternativerne ud fra den samme belastningsprofil: pakkest\u00f8rrelser, forbindelseshastighed, antal regler, tunneler, kryptering og forventet spidsbelastning. Her skal du skelne mellem CPU-andele i datavejen og applikationsarbejdet og unders\u00f8ge, hvilke flows der rent faktisk k\u00f8rer i hardware. En <strong style=\"font-weight:700;color:inherit\">CPU-flaskehals<\/strong> Brug af firewall, overlay eller virtuel videresendelse er en v\u00e6gtig grund til vurdering; en generelt h\u00f8j systembelastning er det ikke.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"betrieb-und-monitoring\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"betrieb-und-monitoring\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">G\u00f8re offload synlig under drift<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Efter implementeringen er det ikke nok blot at se en offload-indstilling som aktiv. Et p\u00e5lideligt driftsbevis forbinder <strong style=\"font-weight:700;color:inherit\">Flow-status<\/strong> med kortets t\u00e6llere, drop- og fejlprocenter, CPU-udnyttelse samt en belastningsprofil, der ligner den senere trafik. F\u00f8rst samlet set viser disse data, om relevante flows rent faktisk behandles i hardwaren, eller om v\u00e6rten fortsat b\u00e6rer den afg\u00f8rende del af datavejen.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For at kunne foretage en sammenligning b\u00f8r operat\u00f8rer tage h\u00f8jde for de samme pakkest\u00f8rrelser, protokoller, antal forbindelser og retningslinjer b\u00e5de f\u00f8r og efter en \u00e6ndring. Ren gigabit-gennemstr\u00f8mning kan let skjule en flaskehals ved sm\u00e5 pakker eller mange parallelle flows. Lige s\u00e5 vigtige er latenstid, CPU-tid pr. involveret v\u00e6rt, Softirq-belastning, k\u00f8-tab og fordelingen af trafikken p\u00e5 noder og porte.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-1024x683.webp\" class=\"wp-image-21966\" alt=\"Netv\u00e6rksporte p\u00e5 en rack-server med tilsluttede fiberoptiske kabler under en teknisk kontrol.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-genereret illustrativt billede til overv\u00e5gning af fysiske netv\u00e6rksstier og deres alternative ruter.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">F\u00f8lgende kommandoer \u00e6ndrer ikke nogen konfiguration. Den f\u00f8rste foresp\u00f8rgsel tager h\u00f8jde for b\u00e5de PCI-enheder, der vises som Ethernet-controllere, og dem, der vises som netv\u00e6rkscontrollere. <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">ethtool -k<\/code> viser de tilbudte eller p\u00e5 Netdev aktiverede offload-funktioner, men dokumenterer hverken eSwitch-, SmartNIC- eller flow-offload fuldt ud. Ogs\u00e5 de \u00f8vrige udskrifter er inventar- og konfigurationsdata og udg\u00f8r ikke bevis for, at en bestemt regel er fuldt ud udlagt.<\/p>\n<div class=\"wh-code-window\" data-wh-code style=\"margin:28px 0 34px;border:1px solid #2c4656;border-radius:12px;overflow:hidden;background:#132a3b;box-shadow:0 9px 25px -13px rgba(15,35,55,.2)\"><div class=\"wh-code-toolbar\" style=\"display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:10px;padding:11px 16px;background:#223e50;color:#edf5fa;font-size:13px;line-height:1.5;font-weight:600\"><span>Terminal<\/span><button type=\"button\" class=\"wh-code-copy\" data-wh-copy hidden style=\"padding:6px 11px;border:1px solid #7893a1;border-radius:6px;background:transparent;color:#fff;font-size:12px;line-height:1.5;font-weight:600;cursor:pointer\">Kopier kode<\/button><span class=\"wh-copy-status\" aria-live=\"polite\"><\/span><span data-wh-copy-success hidden>Kopieret<\/span><span data-wh-copy-fallback hidden>Kode er markeret \u2013 kopier venligst<\/span><\/div><pre class=\"wh-code\" data-no-translation translate=\"no\" style=\"display:block;margin:0;padding:20px;max-width:100%;overflow-x:auto;color:#edf5fa;background:#132a3b;font:14px\/1.75 ui-monospace,SFMono-Regular,Menlo,Consolas,monospace;white-space:pre;direction:ltr;text-align:left\"><code class=\"language-bash\" style=\"font:inherit;color:inherit;background:transparent;padding:0;border:0;white-space:inherit\">lspci -nn | grep -Ei &#039;Ethernet controller|Network controller&#039;\nethtool -k &lt;interface&gt;\nethtool -i &lt;interface&gt;\ndevlink dev show\novs-vsctl get Open_vSwitch . other_config<\/code><\/pre><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I forbindelse med Open vSwitch skal der is\u00e6r skelnes mellem konfigureret hardwareacceleration og det observerede resultat. OVS 4.0.90-udviklingsdokumentationen betegner dens flow-hardware-offload som eksperimentel og beskriver fuldst\u00e6ndig eller delvis offload kun for denne OVS-med-DPDK-konfiguration. I produktionsdrift skal flowoplysninger og hardwaret\u00e6llere derfor evalueres sammen med v\u00e6rtssoftwaret\u00e6llerne. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Overv\u00e5gning kr\u00e6ver desuden en tidsreference. En kort test kan bekr\u00e6fte regler, mens en profil, der ligger t\u00e6t p\u00e5 produktionsforholdene, senere kan udl\u00f8se tabelkapaciteter, sj\u00e6ldne logstier eller rekonfigurationer. Det er derfor fornuftigt at registrere normalv\u00e6rdier og afvigelser for hver kortmodel, firmware, driver og platformversion. P\u00e5 den m\u00e5de kan man efter opdateringer spore, om <strong style=\"font-weight:700;color:inherit\">Datasti<\/strong> eller blot har \u00e6ndret den observerede belastning.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I OpenShift 4.22-integrationen skal visningen desuden d\u00e6kke hele kommunikationsvejen. Den dokumenterede underst\u00f8ttelse af hardware-offload g\u00e6lder kun for bestemte arbejdsbelastninger og kommunikationstyper. Hvis en kompatibel node kommunikerer med en node uden et passende SmartNIC, behandler denne sin del i kernen; m\u00e5lepunkter p\u00e5 kun \u00e9n v\u00e6rt kan derfor give et ufuldst\u00e6ndigt billede af end-to-end-stien. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"fehlerbilder-und-rueckfall\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"fehlerbilder-und-rueckfall\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Typiske fejlm\u00f8nstre og tilbagefaldsforl\u00f8b<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Den mest almindelige fejl er <strong style=\"font-weight:700;color:inherit\">ufuldst\u00e6ndig overf\u00f8rsel<\/strong>. En str\u00f8m kan genkendes i hardwaren p\u00e5 baggrund af enkle kendetegn, men skal dog helt eller delvist vende tilbage til softwareforl\u00f8bet, hvis der er tale om en handling, der ikke underst\u00f8ttes. Den eksperimentelle OVS 4.0.90-dokumentation beskriver denne delvise offload for sin DPDK-konfiguration. Dette er ikke en generel udtalelse om enhver OVS-installation, men illustrerer det n\u00f8dvendige kontrolpunkt ved enhver konkret integration. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Diagnosen starter langs den faktiske rute: indgangsport, virtuel funktion eller repr\u00e6sentor, switch-regel, tunnel- eller policy-behandling og m\u00e5larbejdsbelastning. Hvis t\u00e6llerne f\u00f8r og efter et trin ikke stemmer overens p\u00e5 en plausibel m\u00e5de, er det en anledning til at kontrollere match, handlinger og fallback. En aktiveret funktion erstatter ikke denne tilknytning, da kortets kapacitet ikke omfatter alle \u00f8nskede regelkombinationer.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Heterogene klynger g\u00f8r sammenligningen vanskeligere. I OpenShift 4.22 finder hardware-offload kun sted, hvis de involverede pods og tjenester er tildelt noder med kompatible SmartNIC\u2019er. Hvis en s\u00e5dan sti st\u00f8der p\u00e5 en almindelig node, foreg\u00e5r behandlingen heraf i kernen, hvilket begr\u00e6nser den samlede kommunikation. En enkelt accelereret node optager derfor ikke en fuldt accelereret klyngesti. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Ogs\u00e5 en forkert pod- eller netv\u00e6rkskonfiguration kan forhindre den forventede effekt. Red Hat g\u00f8r udtrykkeligt opm\u00e6rksom p\u00e5, at aktiveret hardware-offload uden tilsvarende konfigurerede pods kan forringe pod-gennemstr\u00f8mningen i forbindelse med OpenShift 4.22-funktionen. Operat\u00f8rer b\u00f8r derfor ikke fors\u00f8ge at afhj\u00e6lpe en afvigelse ved at aktivere yderligere indstillinger, men i stedet f\u00f8rst kontrollere arbejdsbelastningstilkoblingen, netv\u00e6rksmodus og de faktisk opn\u00e5ede flows. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Reguleringskapacitet og firmwareafvigelser h\u00f8rer til samme fejlklasse: Ved mange klienter, kortvarige forbindelser eller dynamiske politikker kan den relevante flowm\u00e6ngde vokse anderledes end forventet. En versionsafh\u00e6ngig driver eller afvigende firmware kan desuden tilbyde funktioner p\u00e5 en anden m\u00e5de end den planlagte platformskombination. Derfor skal inventardata og t\u00e6llere altid arkiveres sammen med den konkrete regelbestand.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En <strong style=\"font-weight:700;color:inherit\">kontrolleret tilbagef\u00f8rselsvej<\/strong> sikrer, at driften kan diagnosticeres. Det betyder, at softwarebehandlingen bevares som det tilsigtede alternativ, og at \u00e6ndringer implementeres trinvist med sammenligningsvinduer og klare afbrydelseskriterier. Software-fallback er i denne sammenh\u00e6ng ikke n\u00f8dvendigvis en fejl, men kan v\u00e6re den forventede h\u00e5ndtering af handlinger, som den valgte hardwarevej ikke underst\u00f8tter fuldt ud.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"entscheidungsrahmen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"entscheidungsrahmen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Tr\u00e6ffe realistiske beslutninger om indk\u00f8b og drift<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En indk\u00f8bsbeslutning tager udgangspunkt i arbejdsbyrden, ikke i portens hastighed eller produktbetegnelsen. Specialiseret hardware er en fornuftig l\u00f8sning, n\u00e5r det kan p\u00e5vises, at gentagen pakkebehandling optager CPU-tid: for eksempel ved mange virtuelle netv\u00e6rk, faste s\u00e6t af politikker, overlay-trafik eller en defineret krypteringsvej. Mangler dette bevis, kan CPU- og k\u00f8-tuning eller et klassisk netv\u00e6rkskort med passende basis-offloads v\u00e6re den enklere l\u00f8sning.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Dern\u00e6st skal <strong style=\"font-weight:700;color:inherit\">Kompatibilitetsbevis<\/strong> for den konkrete kombination: kortmodel og driftsmodus, firmware, driver, kerne, virtuel switch eller CNI samt de n\u00f8dvendige match- og action-funktioner. Programmerbare infrastrukturacceleratorer kan f.eks. tilbyde flow-offload til tilstands- eller sessionsrelaterede funktioner; det betyder dog ikke, at alle SmartNIC'er eller alle platforme tilbyder den samme funktion. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Den forventede aflastning af CPU\u2019en er f\u00f8rst tilg\u00e6ngelig som kapacitet, hvis pakkebehandlingen var den faktiske flaskehals, og de frigjorte kerner kan udnyttes fornuftigt. Hvis de f.eks. planl\u00e6gges til databaser, web-workere eller som reserver, er det et arkitektonisk valg og ikke en automatisk ydeevneforbedring. Det \u00f8vrige serverudstyr er derfor stadig afg\u00f8rende; CPU, arbejdshukommelse og lagerplads skal passe til applikationen lige s\u00e5 godt som netv\u00e6rket. Artiklen om giver mere kontekst til den samlede vurdering <a href=\"https:\/\/webhosting.de\/da\/high-performance-webhosting-hardware-cpu-nvme-memory-performance-turbo-server\/\">pr\u00e6stationsrelevant serverhardware inden for webhosting<\/a>.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Ved IPsec er kontrollen s\u00e6rligt konkret: De dokumenterede offload-varianter sp\u00e6nder fra krypto-offload til fuldst\u00e6ndig udlicitering af indkapsling, udpakning, kryptering og replay-beskyttelse. Hvilken variant der kan anvendes, afh\u00e6nger af model, generation, firmware og kryptokonfiguration. Produktrelaterede bem\u00e6rkninger kan desuden indeholde begr\u00e6nsninger for bestemte generationer eller b\u00e5ndbredder; disse skal indg\u00e5 i godkendelseskontrollen inden implementeringen.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En DPU udvider beslutningen med sit eget administrations- og tillidsomr\u00e5de. I BlueField-DPU-tilstand styrer det integrerede Arm-system NIC-ressourcer og datavejen, i stedet for at kortet blot fungerer som en host-adapter. Dette kan adskille infrastrukturopgaver fra v\u00e6rten, men kr\u00e6ver et robust koncept for adgangsrettigheder, images, opdateringer, overv\u00e5gning og gendannelse. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">\u00d8konomisk set er det derfor ikke kun kortprisen, der t\u00e6ller. P\u00e5 den anden side skal man tage h\u00f8jde for den host-CPU-kapacitet, der spares eller undg\u00e5s, platformens forventede levetid samt ekstra omkostninger til kvalificering, reservedele, firmwarevedligeholdelse og genopretning efter h\u00e6ndelser. Et SmartNIC er en fornuftig l\u00f8sning, hvis denne beregning bygger p\u00e5 en reproducerbar datavej og en livscyklus, der kan styres p\u00e5 lang sigt \u2013 ikke fordi specialiseret hardware generelt forekommer hurtigere.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Kilder og den aktuelle videnskabelige viden<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Status for unders\u00f8gelsen: <time datetime=\"2026-10-24\">2026-10-24<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Status for unders\u00f8gelsen: 24.10.2026. Oplysninger om funktioner og kompatibilitet afh\u00e6nger af version, model og platform; inden udrulningen g\u00e6lder de respektive producent- og platformmatricer.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.kernel.org\/networking\/switchdev.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.openvswitch.org\/en\/latest\/howto\/dpdk\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/doca\/archive\/2-5-3\/nvidia%2Bbluefield%2Bdpu%2Bmodes%2Bof%2Boperation\/index.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.kernel.org\/6.16\/networking\/representors.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.redhat.com\/en\/documentation\/openshift_container_platform\/4.22\/html\/hardware_networks\/configuring-hardware-offloading<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/doca\/archive\/doca-v2.2.1\/ipsec-programming-guide\/index.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.amd.com\/r\/en-US\/ug1670-amd-pensando-ssdk-flow-offload-user-guide\/Introduction<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/networking\/display\/MLNXOFEDv23103220lts\/IPsec%2BFull%2BOffload<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.openvswitch.org\/en\/stable\/howto\/dpdk\/<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>SmartNIC\u2019er kan aflaste v\u00e6rts-CPU\u2019erne for tilbagevendende netv\u00e6rksopgaver. Om det kan betale sig, afh\u00e6nger af den faktiske datavej, de underst\u00f8ttede regler, platformintegrationen og den ekstra driftsindsats.<\/p>","protected":false},"author":1,"featured_media":21964,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[922],"tags":[],"class_list":["post-21961","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technologie"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts\/21961","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/comments?post=21961"}],"version-history":[{"count":3,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts\/21961\/revisions"}],"predecessor-version":[{"id":21967,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts\/21961\/revisions\/21967"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/media\/21964"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/media?parent=21961"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/categories?post=21961"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/tags?post=21961"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}