{"id":22107,"date":"2026-11-11T15:00:00","date_gmt":"2026-11-11T14:00:00","guid":{"rendered":"https:\/\/webhosting.de\/?p=22107"},"modified":"2026-11-05T08:25:52","modified_gmt":"2026-11-05T07:25:52","slug":"intel-sierra-forest-xeon-e-kerner-til-servere","status":"publish","type":"post","link":"https:\/\/webhosting.de\/da\/intel-sierra-forest-xeon-e-cores-server\/","title":{"rendered":"Intel Sierra Forest: Xeon E-kerner til parallelle serveropgaver"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">Intel Sierra Forest er interessant for serveropgaver, der behandler mange uafh\u00e6ngige opgaver samtidigt. Xeon 6-processorer med <strong style=\"font-weight:700;color:inherit\">E-kerner<\/strong> til geng\u00e6ld har de en h\u00f8j kerne t\u00e6thed; de unders\u00f8gte modeller sp\u00e6nder fra 64 til 144 kerner. Det betyder dog ikke automatisk, at der er en fordel for enhver anvendelse eller et lavere energiforbrug. Ved valget spiller ogs\u00e5 hukommelse, I\/O, latenstidsm\u00e5l og softwarekompatibilitet en rolle. En sammenligning af komplette servere under repr\u00e6sentativ belastning og med samme servicekvalitet viser, om en konsolidering kan betale sig.  <\/p>\n<nav class=\"wh-toc\" aria-label=\"Indholdet af denne artikel\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">G\u00e5 direkte til afsnittet<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#sierra-forest-einordnung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Sierra Forest inden for Xeon-familien<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#architektur-und-durchsatz\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Mange E-kerner til parallel behandling<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#befehlssaetze-und-grenzen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">E-kerner, P-kerner og softwarekompatibilitet<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#modelle-und-plattform\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Sammenlign modeller, lagerplads og tilslutningsmuligheder<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#hosting-und-virtualisierung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Dimensionering af hosting og virtuelle maskiner<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#lastprofile-und-messplanung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Praktisk sammenligning af belastningsprofiler<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#energie-und-wirtschaftlichkeit\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Inddele energibehov og omkostninger<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#betrieb-und-fehlersuche\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Kontroller drift, firmware og flaskehalse<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#plattformentscheidung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">V\u00e6lg den rette serverplatform<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"sierra-forest-einordnung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"sierra-forest-einordnung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Sierra Forest inden for Xeon-familien<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Intel Sierra Forest er et kodenavn for Xeon 6-serverprocessorer med <strong style=\"font-weight:700;color:inherit\">Effektive kerner<\/strong> (E-Cores). Den unders\u00f8gte produktliste omfatter modeller med 64 til 144 kerner, herunder processorer fra 6700E-serien. Intel retter denne udgave blandt andet mod cloud- og scale-out-applikationer, hvor mange opgaver kan behandles parallelt.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">N\u00e5r man skal v\u00e6lge en server-CPU, er kodenavnet derfor et udgangspunkt, men ikke en fuldst\u00e6ndig specifikation. Modellerne i serien adskiller sig blandt andet med hensyn til antal kerner, klokfrekvens og termisk design. Hvilken kombination der er hensigtsm\u00e6ssig, afh\u00e6nger af, hvor meget arbejde en applikation kan udf\u00f8re samtidigt, og hvilke begr\u00e6nsninger det p\u00e5g\u00e6ldende serversystem s\u00e6tter.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Granite Rapids betegner derimod en anden Xeon 6-produktserie med Performance-kerner (P-kerner). Den er et alternativ, n\u00e5r ydeevnen for de enkelte kerner eller bestemte udvidelser af instruktionss\u00e6ttet er s\u00e6rlig vigtige. Klassificeringen som P-Core eller E-Core alene giver dog ikke noget konkret resultat for en bestemt anvendelse. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Clearwater Forest skal betragtes som den n\u00e6ste generation af E-Cores og Xeon 6+, adskilt fra Sierra Forest. En angivelse af, at Xeon-familien kan have op til 288 E-Cores, er ikke en generel specifikation for Sierra Forest. Hvis man sammenligner tilbud, b\u00f8r man derfor tjekke den konkrete modelbetegnelse og dens specifikationer i stedet for at g\u00e5 ud fra et maksimum fra en anden generation.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"architektur-und-durchsatz\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"architektur-und-durchsatz\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Mange E-kerner til parallel behandling<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Sierra Forest anvender en modul\u00e6r arkitektur med flere chips: Beregnings- og I\/O-moduler er samlet i processorpakken. Beregningsmodulerne leverer kernerne til databehandlingen, mens I\/O-siden s\u00f8rger for forbindelserne til platformen. For applikationen er det ikke s\u00e5 meget antallet af moduler, der t\u00e6ller, men snarere, om deres arbejde kan fordeles p\u00e5 de tilg\u00e6ngelige kerner. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Mange kerner kan f.eks. behandle adskillige uafh\u00e6ngige webforesp\u00f8rgsler eller baggrundsopgaver samtidigt. Den <strong style=\"font-weight:700;color:inherit\">Gennemstr\u00f8mning<\/strong> beskriver herved m\u00e6ngden af udf\u00f8rt arbejde pr. tidsenhed, for eksempel antallet af succesfuldt besvarede foresp\u00f8rgsler pr. sekund. Hvis denne v\u00e6rdi stiger, betyder det ikke automatisk, at hver enkelt foresp\u00f8rgsel besvares hurtigere.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Her er latenstiden afg\u00f8rende: Den angiver den tid, det tager at behandle en enkelt foresp\u00f8rgsel eller operation. Hvis flere tjenester venter p\u00e5 den samme database eller et overbelastet lager, kan yderligere CPU-kerner ganske vist p\u00e5tage sig mere arbejde, men de kan ikke alene fjerne ventetiden. Is\u00e6r ved belastningsspidser skal man derfor ud over gennemstr\u00f8mningen ogs\u00e5 tage responstiden i betragtning.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Med <strong style=\"font-weight:700;color:inherit\">Scale-out<\/strong> Arbejdet fordeles p\u00e5 flere instanser eller servere. Flere sm\u00e5 serviceinstanser kan s\u00e5ledes k\u00f8re parallelt, forudsat at de er tilstr\u00e6kkeligt uafh\u00e6ngige, og at f\u00e6lles ressourcer ikke udg\u00f8r en flaskehals. En enkelt seriel opgave bliver derimod ikke automatisk hurtigere af, at der er ekstra ubrugte kerner; dens p\u00e5 hinanden f\u00f8lgende trin forbliver afh\u00e6ngige af hinanden.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Fordelingen p\u00e5 tv\u00e6rs af procesgr\u00e6nser eller servere kan ikke sidestilles med opbygningen af en CPU. Det supplerende indl\u00e6g til <a href=\"https:\/\/webhosting.de\/da\/swarm-computing-kollektiv-intelligens-it-systemer\/\">Swarm Computing og decentralt samarbejde<\/a> omhandler et andet koncept for distribuerede systemer. For Sierra Forest er det afg\u00f8rende, om den konkrete software genererer tilstr\u00e6kkeligt mange opgaver, der kan udf\u00f8res parallelt, til de tilg\u00e6ngelige kerner.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"befehlssaetze-und-grenzen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"befehlssaetze-und-grenzen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">E-kerner, P-kerner og softwarekompatibilitet<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Sierra Forest og P-Core-versionen af Xeon 6 h\u00f8rer til x86-verdenen. Det g\u00f8r det lettere at klassificere eksisterende software, men det betyder ikke, at begge processortyper underst\u00f8tter alle udvidelser p\u00e5 samme m\u00e5de eller leverer den samme ydeevne i den samme applikation. Ved en migrering skal man derfor unders\u00f8ge b\u00e5de de eksekverbare programmer og deres faktiske krav. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Intel angiver blandt andet f\u00f8lgende for Xeon 6E-kerner: <strong style=\"font-weight:700;color:inherit\">AVX2 og VNNI<\/strong>. S\u00e5danne udvidelser af instruktionss\u00e6ttet kan underst\u00f8tte bestemte beregninger; om et program bruger dem og drager fordel af dem, afh\u00e6nger af dets kode og biblioteker. Deres blotte tilstedev\u00e6relse giver derfor ikke mulighed for at sige noget om den gennemstr\u00f8mning, en tjeneste kan opn\u00e5. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I Xeon 6 er <strong style=\"font-weight:700;color:inherit\">AVX-512<\/strong> If\u00f8lge Intel er denne funktion forbeholdt P-Core-processorer. Hvis et program kr\u00e6ver denne udvidelse, er det et direkte kompatibilitetskriterium, der udelukker den u\u00e6ndrede udgave p\u00e5 Sierra Forest. Hvis det kun bruger AVX-512 som en valgmulighed, kan det muligvis k\u00f8re med en anden kodesti; dens ydeevne skal dog vurderes separat. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">F\u00f8r du skifter platform, b\u00f8r du derfor ikke kun kontrollere hovedapplikationen, men ogs\u00e5 dens k\u00f8rselsmilj\u00f8 og beregningsintensive biblioteker med hensyn til deres CPU-krav. Producentens dokumentation og de faktisk anvendte softwareversioner er i denne sammenh\u00e6ng vigtigere end antagelsen om, at ethvert x86-pakke tilbyder samme funktionsomfang p\u00e5 alle Xeon-varianter.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Kompatibilitetstesten viser desuden kun, om softwaren kan k\u00f8re. Om en E-Core-konfiguration kan udf\u00f8re tilstr\u00e6kkeligt arbejde med et givet latensm\u00e5l, viser f\u00f8rst en sammenligning med den reelle anvendelse og passende serverudstyr. Til st\u00e6rkt serielle eller AVX-512-intensive opgaver er et P-Core-system derfor et vigtigt sammenligningsgrundlag, men ikke automatisk den bedste l\u00f8sning.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"modelle-und-plattform\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"modelle-und-plattform\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Sammenlign modeller, lagerplads og tilslutningsmuligheder<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Hos Sierra Forest er modelnummeret mere sigende end selve antallet af kerner. Til en forel\u00f8big udv\u00e6lgelse kan man for eksempel overveje modellerne 6710E, 6756E, 6766E og 6780E. Sammenlign ikke kun kerner og tr\u00e5de, men ogs\u00e5 basis- og turbo-klokfrekvens samt den respektive ydeevneprofil: Det samme antal kerner siger ikke n\u00f8dvendigvis noget om, hvor meget termisk spillerum en server skal kunne tilbyde. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Sammenligning af to Sierra Forest-modeller med samme antal kerner\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Sammenligning af to Sierra Forest-modeller med samme antal kerner<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Model<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Kerner<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">TDP i serverprofilen<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Xeon 6766E<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">144<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">250 W<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Xeon 6780E<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">144<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">330 W<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Xeon 6780E har 144 kerner og 144 tr\u00e5de. Intel angiver en basisfrekvens p\u00e5 2,2 GHz og op til 3,0 GHz i Turbo-tilstand; TDP-v\u00e6rdien p\u00e5 330 W g\u00e6lder for den angivne serverprofil. Den maksimale turbofrekvens er ikke en garanteret vedvarende v\u00e6rdi for alle kerner og alle driftssituationer. For 6766E samt 6710E og 6756E b\u00f8r du tjekke frekvens- og profildata separat i produktsammenligningen, inden du tr\u00e6ffer dit valg.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Forskellen mellem de to modeller med 144 kerner p\u00e5virker s\u00e5ledes ogs\u00e5 udformningen af k\u00f8ling og str\u00f8mforsyning. Ud fra TDP-v\u00e6rdierne alene kan man dog hverken udlede det m\u00e5lte str\u00f8mforbrug eller en applikations ydeevne. Det afg\u00f8rende er, hvilken model der udf\u00f8rer det n\u00f8dvendige arbejde inden for de fastsatte ydeevnegr\u00e6nser og med den faktiske belastning.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For 6780E n\u00e6vner Intel otte <strong style=\"font-weight:700;color:inherit\">Lagringskanaler<\/strong>, maksimalt DDR5-6400, op til 88 PCIe 5.0-baner og underst\u00f8ttelse af systemer med to sokler. Du b\u00f8r kontrollere, hvilken hukommelseshastighed der faktisk underst\u00f8ttes ved den planlagte DIMM-konfiguration, ved at se p\u00e5 godkendelserne for det konkrete serversystem og de valgte hukommelsesmoduler. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"hosting-und-virtualisierung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"hosting-und-virtualisierung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Dimensionering af hosting og virtuelle maskiner<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Mange uafh\u00e6ngige webinstanser kan udnytte det h\u00f8je antal kerner, hvis der rent faktisk behandles tilstr\u00e6kkeligt mange anmodninger samtidigt. Ved planl\u00e6gningen er det dog ikke kun antallet af installerede instanser, der t\u00e6ller, men antallet af samtidigt aktive tjenester ved et fastsat svarstidsm\u00e5l. En server kan vise ledig CPU-kapacitet og alligevel ikke n\u00e5 m\u00e5let, hvis anmodninger venter p\u00e5 hukommelse eller lagerplads.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Vurder derfor f\u00f8rst arbejdshukommelsen pr. instans, inklusive applikation, cache og operativsystemets andel. Tag derefter h\u00f8jde for belastningsspidser og reserver til vedligeholdelse eller nedbrud af en host. Hvis RAM-kapaciteten ikke l\u00e6ngere er tilstr\u00e6kkelig f\u00f8r regnekraften, hj\u00e6lper et h\u00f8jere antal kerner alene ikke med den \u00f8nskede konsolidering.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Ogs\u00e5 storage-I\/O p\u00e5virker den opn\u00e5elige t\u00e6thed: Hvis mange instanser samtidig l\u00e6ser, skriver eller genererer logfiler, kan der opst\u00e5 k\u00f8er. Kontroller derfor under realistiske samtidighedsforhold ikke kun den gennemsnitlige gennemstr\u00f8mning, men ogs\u00e5 de langsomme foresp\u00f8rgsler. Et p99-m\u00e5l beskriver for eksempel den responstid, som mindst 99 procent af de unders\u00f8gte foresp\u00f8rgsler skal overholde.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For virtuelle maskiner er en tildelt <strong style=\"font-weight:700;color:inherit\">vCPU<\/strong> F\u00f8rst og fremmest en virtuel eksekveringsenhed \u2013 der foretages ingen automatisk reservation af en fysisk kerne. Hvis flere virtuelle maskiner deler de samme ressourcer, afh\u00e6nger den tilg\u00e6ngelige regnetid og responstiderne ogs\u00e5 af deres samtidige aktivitet og hypervisorens indstillinger. Planl\u00e6g derfor reservationer og overbooking ud fra de enkelte tjenesters krav.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Til en server med to sokler og en 6780E b\u00f8r du desuden v\u00e6lge <strong style=\"font-weight:700;color:inherit\">NUMA-topologi<\/strong> Kontroller: Adgang til hukommelsen kan afh\u00e6nge af, hvilken sokkel hukommelsen er tilsluttet, og hvor den virtuelle maskine k\u00f8rer. Kontroller hukommelseskonfigurationen og placeringen i hypervisoren, og sammenlign lokale og eksterne adgangsforesp\u00f8rgsler under belastning. Intels underst\u00f8ttelse af to sokler erstatter ikke godkendelsen af den konkrete server og hypervisor til den valgte CPU. <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/zwei-sockel-server-speicher-draufsicht-bec69f31-detail1-a6c0f54e95-1024x683.webp\" class=\"wp-image-22118\" alt=\"Et AI-genereret symbolbillede af en \u00e5ben server med to sokler og monteret hukommelse, set ovenfra.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/zwei-sockel-server-speicher-draufsicht-bec69f31-detail1-a6c0f54e95-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/zwei-sockel-server-speicher-draufsicht-bec69f31-detail1-a6c0f54e95-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/zwei-sockel-server-speicher-draufsicht-bec69f31-detail1-a6c0f54e95-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/zwei-sockel-server-speicher-draufsicht-bec69f31-detail1-a6c0f54e95-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/zwei-sockel-server-speicher-draufsicht-bec69f31-detail1-a6c0f54e95.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-genereret illustrativt billede: I systemer med to sokler indg\u00e5r hukommelseskonfigurationen i planl\u00e6gningen af NUMA-lokaliseringen.<\/figcaption><\/figure><\/section><section class=\"wh-section\" aria-labelledby=\"lastprofile-und-messplanung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"lastprofile-und-messplanung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Praktisk sammenligning af belastningsprofiler<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En m\u00e5leplanl\u00e6gning starter med en konkret beslutning: Hvor mange k\u00f8-arbejdere eller netv\u00e6rksforesp\u00f8rgsler kan den nye konfiguration behandle med samme servicekvalitet sammenlignet med den eksisterende server eller et P-Core-system? Fastl\u00e6g til dette form\u00e5l den samme applikation, datam\u00e6ngde og definerede samtidighed for begge kandidater. Den f\u00f8lgende fremgangsm\u00e5de er en egen metodisk anbefaling, ikke en dokumenteret Intel-testprocedure og ikke en beskrivelse af en gennemf\u00f8rt test.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-lastvergleich-illustration-bec69f31-detail2-128b1de302-1024x683.webp\" class=\"wp-image-22120\" alt=\"AI-genereret illustration af to serversymboler med f\u00e6lles opgavefordeling og urform.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-lastvergleich-illustration-bec69f31-detail2-128b1de302-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-lastvergleich-illustration-bec69f31-detail2-128b1de302-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-lastvergleich-illustration-bec69f31-detail2-128b1de302-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-lastvergleich-illustration-bec69f31-detail2-128b1de302-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-lastvergleich-illustration-bec69f31-detail2-128b1de302.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-genereret illustration: Et f\u00e6lles opgaves\u00e6t g\u00f8r det lettere at sammenligne, n\u00e5r latenstidsm\u00e5let er det samme.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For arbejdere b\u00f8r testen indeholde tilstr\u00e6kkeligt mange uafh\u00e6ngige opgaver, s\u00e5 yderligere kerner overhovedet kan udnyttes. Registrer afsluttede opgaver pr. tidsinterval samt tiden indtil afslutningen; hold desuden \u00f8je med, om databasen, lagringsmediet eller eksterne gr\u00e6nseflader begr\u00e6nser forl\u00f8bet. En enkelt seriel opgave er ikke egnet som eneste grundlag for vurderingen af en platform, der er designet til parallelitet.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For at kunne sammenligne netv\u00e6rkstjenester p\u00e5 egen h\u00e5nd b\u00f8r du ogs\u00e5 dokumentere pakkest\u00f8rrelse, kryptering, netv\u00e6rkskort og drivere. Hvis applikationen skal bruge acceleratorer, skal du kontrollere, om disse er tilg\u00e6ngelige for den konkrete CPU- og serverkonfiguration, samt om den anvendte software underst\u00f8tter dem. Sammenlign derefter under samme belastning, om brugen af dem giver en fordel, i stedet for at udlede det ud fra en specifikation.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Indtast f\u00f8rst <strong style=\"font-weight:700;color:inherit\">p95- eller p99-latensm\u00e5l<\/strong> Fastl\u00e6g belastningen og \u00f8g den i overskuelige trin. Registrer samtidig gennemstr\u00f8mningen og fejlprocenten sammen med ventetiden: Flere foresp\u00f8rgsler pr. sekund er ikke n\u00f8dvendigvis et bedre resultat, hvis det aftalte svarstidsm\u00e5l overskrides, eller hvis antallet af fejl stiger. Gentag analysen ogs\u00e5 for de forventede belastningstoppe.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">M\u00e5l den elektriske effekt af <strong style=\"font-weight:700;color:inherit\">Hele systemet<\/strong> i tomgang samt ved delbelastning og spidsbelastning. Not\u00e9r hardwarekonfiguration, firmware, ydeevneprofil, softwareversioner og m\u00e5letid, s\u00e5 forskelle ikke ved en fejltagelse tilskrives udelukkende CPU\u2019en. Ud fra det udf\u00f8rte arbejde og den dertil n\u00f8dvendige energi kan man derefter sammenligne arbejdet pr. energienhed, forudsat at servicekvaliteten forbliver den samme.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"energie-und-wirtschaftlichkeit\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"energie-und-wirtschaftlichkeit\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Inddele energibehov og omkostninger<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Den angivne <strong style=\"font-weight:700;color:inherit\">TDP<\/strong> er et vejledende tal for processoren, ikke en m\u00e5ling af den samlede server. For Xeon 6780E angiver Intel en TDP p\u00e5 330 watt for den angivne serverprofil. Herfra kan man hverken umiddelbart udlede det faktiske energiforbrug ved en bestemt belastning eller str\u00f8momkostningerne. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For at f\u00e5 et p\u00e5lideligt sammenligningsgrundlag er det det samlede systems elektriske str\u00f8mforbrug, der t\u00e6ller, herunder lagerenheder, harddiske og netv\u00e6rkskort. Dette \u00e6ndrer sig afh\u00e6ngigt af belastningen. M\u00e5l derfor over en repr\u00e6sentativ periode, og registrer b\u00e5de tomgang samt typisk og h\u00f8j belastning; en enkelt spidsv\u00e6rdi giver kun et ufuldst\u00e6ndigt billede af driften.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Die <strong style=\"font-weight:700;color:inherit\">Arbejde pr. energienhed<\/strong> kan f.eks. udtrykkes som antallet af vellykkede foresp\u00f8rgsler divideret med det m\u00e5lte energiforbrug. Man b\u00f8r her kun sammenligne arbejde, der opfylder de samme krav: En h\u00f8jere gennemstr\u00f8mning har ringe v\u00e6rdi, hvis fejlprocenten eller svartiderne overskrider det aftalte m\u00e5l. Ogs\u00e5 datam\u00e6ngden og belastningsforl\u00f8bet skal v\u00e6re sammenlignelige.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Selv dette forhold er ikke tilstr\u00e6kkeligt for at sikre rentabiliteten. Medregn str\u00f8m og k\u00f8ling sammen med rackplads, indk\u00f8b af hardware, vedligeholdelse og softwarelicenser. Is\u00e6r ved kerneafh\u00e6ngige licensmodeller kan et h\u00f8jt antal kerner \u00e6ndre regnestykket; det afg\u00f8rende er de konkrete kontraktbetingelser, ikke en antaget licensregel.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En konsolidering medf\u00f8rer desuden en indsats i forbindelse med migrering: Applikationer skal gennemg\u00e5s, data skal overf\u00f8res, og driftsprocedurer skal tilpasses. Sammenlign disse engangsomkostninger og eventuelle nedbrudsrisici med de l\u00f8bende omkostninger. Fortsat drift af eksisterende servere er stadig en seri\u00f8s mulighed, hvis deres anvendelige kapacitet og driftsomkostninger er tilstr\u00e6kkelige i den planlagte periode.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"betrieb-und-fehlersuche\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"betrieb-und-fehlersuche\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Kontroller drift, firmware og flaskehalse<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Hvis den <strong style=\"font-weight:700;color:inherit\">Tail-latens<\/strong>, start med at se p\u00e5 tidspunktet og den p\u00e5g\u00e6ldende foresp\u00f8rgselsk\u00e6de. Unders\u00f8g, om fejlraten, k\u00f8erne eller antallet af parallelle foresp\u00f8rgsler samtidig stiger. En h\u00f8j p99-latens betyder, at de langsomste foresp\u00f8rgsler kan ligge uden for den \u00f8nskede tidsramme; gennemsnittet alene viser muligvis ikke dette problem.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Unders\u00f8g derefter CPU-udnyttelsen og arbejdsfordelingen. En generelt lav udnyttelse udelukker ikke, at der er flaskehalse i enkelte tr\u00e5de. Er der derimod mange kerner i brug, skal du kontrollere, om der er tilstr\u00e6kkeligt med uafh\u00e6ngige opgaver, eller om synkronisering og ventetider begr\u00e6nser den ekstra gennemstr\u00f8mning.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I et system med to sokler h\u00f8rer <strong style=\"font-weight:700;color:inherit\">Opbevaringssted<\/strong> Fejlfinding: Kontroller NUMA-tildelingen af processer eller virtuelle maskiner og deres hukommelse. Xeon 6780E underst\u00f8tter systemer med to sokler; om den konkrete placering er gunstig for en given applikation, afh\u00e6nger dog ogs\u00e5 af serveren og hypervisorens indstillinger. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Hvis \u00e5rsagen stadig er ukendt, skal du overv\u00e5ge hukommelses- og lagrings-I\/O samt netv\u00e6rksstier og eksterne tjenester. Forsinkede svar fra databasen eller overbelastede netv\u00e6rksforbindelser kan forl\u00e6nge foresp\u00f8rgslerne, uden at serverens CPU er fuldt udnyttet hele tiden. Sammenlign m\u00e5lev\u00e6rdierne over tid med de langsomme foresp\u00f8rgsler, i stedet for forhastet at antage, at antallet af kerner er \u00e5rsagen.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Inden indk\u00f8b og implementering skal du kontrollere serverproducentens liste over godkendte CPU\u2019er, soklen, den kr\u00e6vede BIOS-version og underst\u00f8ttelsen fra hypervisoren. Intel angiver LGA4710-2 for 6700E-serien og LGA7529-1 for 6900P; heraf kan man ikke udlede, at der er generel udskiftbarhed mellem Xeon-serierne. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Se desuden specifikationsopdateringen for den anvendte processorserie. Kontroller relevante errat og pr\u00e6ciseringer i forhold til den konkrete stepping og firmwareversion, og tag om n\u00f8dvendigt h\u00f8jde for dokumenterede afhj\u00e6lpninger. P\u00e5 denne m\u00e5de suppleres godkendelsen af det samlede system med kendte tekniske begr\u00e6nsninger. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"plattformentscheidung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"plattformentscheidung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">V\u00e6lg den rette serverplatform<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Valget starter med anvendelsen, ikke med den h\u00f8jeste v\u00e6rdi i databladet. Intel positionerer Xeon 6 E-kerner til h\u00f8j kerne-t\u00e6thed og parallel gennemstr\u00f8mning af opgaver, mens P-kerner derimod er beregnet til h\u00f8j ydeevne pr. kerne. Det afg\u00f8r dog ikke, hvilken platform der opfylder dit m\u00e5l for latenstid og dine kapacitetskrav. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Intels beskrivelse af konfigurationerne for Xeon-6-kernetyperne, ingen rangliste over ydeevne\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Intels beskrivelse af konfigurationerne for Xeon-6-kernetyperne, ingen rangliste over ydeevne<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Kernetype<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Arkitekturretning if\u00f8lge Intel<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Afgr\u00e6nsning af instruktionss\u00e6ttet<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">E-kerner<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">H\u00f8j kerne-t\u00e6thed og opgaveparallelt genneml\u00f8b til cloud-skala-belastninger<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">AVX2 og VNNI; ingen AVX-512<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">P-kerner<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">H\u00f8j ydeevne pr. kerne og beregningskr\u00e6vende opgaver<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">AVX-512 underst\u00f8ttes<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Brug tabellen som udgangspunkt for en <strong style=\"font-weight:700;color:inherit\">Sammenligning ved samme servicekvalitet<\/strong>, ikke som en pr\u00e6stationsrangliste. Den f\u00f8lgende udv\u00e6lgelsesmetode er en egen anbefaling og ikke en dokumenteret Intel-testprocedure: Sammenlign den eksisterende platform, en passende Sierra-Forest-konfiguration og eventuelt et P-Core-system med de samme krav til responstid, fejlrate og datam\u00e6ngde. Dokumenter den respektive konfiguration og fastl\u00e6g det komplette systems nyttige ydelse.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Ogs\u00e5 <a href=\"https:\/\/webhosting.de\/da\/arm-baserede-servere-energieffektiv-ydeevne-moderne-datacentre\/\">ARM-baserede servere<\/a> er en mulig sammenligningsmulighed. Til det form\u00e5l skal operativsystemet, applikationerne og de n\u00f8dvendige softwarepakker passe til arkitekturen; derudover kan portning og drift kr\u00e6ve \u00e6ndringer. En generel effektivitetsfordel f\u00f8lger ikke alene af arkitekturbetegnelsen og b\u00f8r unders\u00f8ges under de samme belastningsforhold.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">V\u00e6lg til sidst den platform, der leverer den kr\u00e6vede kapacitet med tilstr\u00e6kkelig reserve og de rette driftsbetingelser til de laveste samlede omkostninger. Tag herved h\u00f8jde for migration og licenser, og v\u00e6gt om n\u00f8dvendigt risici og pladsbehov. Flere kerner er et udv\u00e6lgelseskriterium, men erstatter hverken applikationstesten eller omkostningsberegningen.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Kilder og den aktuelle videnskabelige viden<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Status for unders\u00f8gelsen: <time datetime=\"2026-11-04\">2026-11-04<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Unders\u00f8gelses- og kildestatus: 4. november 2026. Sierra Forest skal betragtes separat fra Granite Rapids og den efterf\u00f8lgende E-Core-generation, Clearwater Forest; de konkrete specifikationer g\u00e6lder for den p\u00e5g\u00e6ldende model.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/ark\/products\/codename\/198508\/products-formerly-sierra-forest.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/support\/articles\/000098612\/processors\/intel-xeon-processors.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/newsroom.intel.com\/data-center\/postcard-from-intel-tech-tour-arizona-intel-data-center-group-leader-kevork-kechichian-shows-off-xeon-6<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/support\/articles\/000099181.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/products\/compare.html?productIds=240361%2C240362%2C240363%2C240365%2C240366%2C240369%2C240359.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/products\/sku\/240362\/intel-xeon-6780e-processor-108m-cache-2-20-ghz\/specifications.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/support\/articles\/000055173.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/edc.intel.com\/content\/www\/de\/de\/design\/products-and-solutions\/processors-and-chipsets\/sierra-forest\/xeon-6700-series-processor-with-e-cores-specification-update\/preface\/<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>Intel Sierra Forest samler mange E-kerner til paralleliserede serveropgaver. Ud over antallet af kerner er hukommelse, latenstid, softwarekompatibilitet og det samlede systems energiforbrug afg\u00f8rende.<\/p>","protected":false},"author":1,"featured_media":22117,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[676],"tags":[],"class_list":["post-22107","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-server_vm"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts\/22107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/comments?post=22107"}],"version-history":[{"count":4,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts\/22107\/revisions"}],"predecessor-version":[{"id":22121,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/posts\/22107\/revisions\/22121"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/media\/22117"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/media?parent=22107"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/categories?post=22107"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/da\/wp-json\/wp\/v2\/tags?post=22107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}