{"id":22123,"date":"2026-11-12T11:30:00","date_gmt":"2026-11-12T10:30:00","guid":{"rendered":"https:\/\/webhosting.de\/?p=22123"},"modified":"2026-11-05T08:25:52","modified_gmt":"2026-11-05T07:25:52","slug":"amd-epyc-turin-server-cpu-hosting","status":"publish","type":"post","link":"https:\/\/webhosting.de\/en\/amd-epyc-turin-server-cpu-hosting\/","title":{"rendered":"AMD EPYC Turin: Choosing the Right Server CPU for Hosting Providers"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">AMD EPYC Turin may be of interest to hosting providers who run many virtual machines or handle parallel web requests on a single host. Which <strong style=\"font-weight:700;color:inherit\">Server CPU<\/strong> It\u2019s a good fit, but the core count alone isn\u2019t the deciding factor: RAM configuration, NVMe connectivity, networking, redundancy, and software licenses are all part of the comparison. Turin refers to the EPYC 9005 generation, introduced in 2024, as featuring Zen 5 and Zen 5c. To make a sound selection, comparable load profiles and measurements of your own hosting hardware are required. <\/p>\n<nav class=\"wh-toc\" aria-label=\"Contents of this article\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">Go directly to the section<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#turin-einordnung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Putting the AMD EPYC Turin in Perspective<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#kerne-chiplets-takt\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Understanding Cores, Chiplets, and Clock Speeds<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#speicher-und-io\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Memory and I\/O Limit Capacity<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#modellvergleich\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Compare Turin hosting plans<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#workloads-engpaesse\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Mapping Hosting Workloads and Bottlenecks<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#vm-kapazitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Planning VM Capacity: An Example<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#plattform-inbetriebnahme\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Preparing the Platform and Virtualization<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#betrieb-fehlersuche\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Measure Operations and Identify Bottlenecks<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#beschaffung-entscheidung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Procurement and Cost-Effectiveness Are the Deciding Factors<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"turin-einordnung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"turin-einordnung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Putting the AMD EPYC Turin in Perspective<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">AMD EPYC Turin refers to the <strong style=\"font-weight:700;color:inherit\">EPYC 9005 Generation<\/strong> server processors. AMD introduced them in October 2024 as the fifth generation of EPYC; the family includes models with Zen 5 and Zen 5c cores. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For hosting providers, Turin is not a single CPU with uniform performance characteristics. The model range spans from eight to 192 cores per processor. Which model is right depends on whether many independent customer requests are running in parallel, whether individual applications require short response times, or whether virtual machines primarily consume a lot of RAM. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The selection process also includes the question of the <strong style=\"font-weight:700;color:inherit\">Base number<\/strong>: A server with a single processor offers a different combination of computing power, memory connectivity, and expandability than a dual-socket platform. Not every model is designed for both configurations; according to the datasheet, processors with a \"P\" suffix are designed for single-socket systems. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The initial selection process therefore begins with the specific customer mix and the requirements for RAM, NVMe drives, and networking. For example, a heavily utilized VPS host requires reserves for simultaneously active virtual machines, while a database server can also respond to storage requirements and I\/O demands. Software licenses and the server manufacturer\u2019s approvals are also part of the planning process.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">More cores alone do not indicate how many existing hosts can be replaced. To determine this, the provider needs comparable load profiles and performance metrics for the existing hosting hardware, as well as a defined failure margin. Without this foundation, it is possible to select a model, but not to determine a reliable consolidation ratio.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"kerne-chiplets-takt\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"kerne-chiplets-takt\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Understanding Cores, Chiplets, and Clock Speeds<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Turin uses a <strong style=\"font-weight:700;color:inherit\">Chiplet Design<\/strong>: Computing units and a separate I\/O die are connected via AMD Infinity Fabric. Among other things, the I\/O die provides connections to memory and to input\/output devices. In terms of practical server planning, this means that it\u2019s not just the cores that matter, but also the connectivity of shared resources. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Zen 5 and Zen 5c differ in their architecture and core organization. Zen 5c offers the highest core density within this generation; however, this does not imply a general performance ranking. A highly parallelized VM mix and an application with few latency-critical tasks may favor different models. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The EPYC 9965 has 192 Zen 5c cores and 384 threads, while the EPYC 9755 has 128 Zen 5 cores and 256 threads. AMD specifies a maximum boost of up to 3.7 GHz for the 9965 and up to 4.1 GHz for the 9755. These figures highlight different strengths, but they do not replace a comparison based on your own workload profile. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The specified <strong style=\"font-weight:700;color:inherit\">maximum boost<\/strong> In particular, there is no guaranteed sustained clock speed for all cores. The frequency achieved under load depends, among other things, on the workload and operating conditions. When making a hosting decision, therefore, throughput and response times under a defined mix of applications are more meaningful than an isolated peak value.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The doubled number of threads is the result of SMT: One physical core provides two logical threads. However, these share core resources; 384 threads are neither 384 physical cores nor an automatic doubling of computing power. Whether SMT and overbooking of CPU resources are helpful must be evaluated based on the concurrent customer load.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"speicher-und-io\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"speicher-und-io\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Memory and I\/O Limit Capacity<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Many CPU cores require an appropriate memory configuration. According to AMD, the EPYC 9005 supports up to twelve DDR5 memory channels per CPU. For a VM host, it\u2019s not just the total RAM capacity that matters: the distribution of the modules and the available memory bandwidth also influence how well concurrently active guests can be supported. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The data sheet lists speeds of up to DDR5-6400 for the models listed at <strong style=\"font-weight:700;color:inherit\">one DIMM per channel<\/strong>. The actual usable speed depends on the hardware configuration and platform support. The up to 6 TB of DDR5 listed in the data sheet also refers to the configurations specified there\u2014with two DIMMs per channel\u2014and is not a guarantee for every server. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Adding more RAM modules may be a good way to achieve the required capacity, but it changes the configuration being tested. Therefore, providers should compare the desired module size and configuration with the server manufacturer\u2019s approval list, rather than simply adding together the maximum capacity and speed values from the datasheet independently of one another.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-ddr5-speicherbestueckung-256fd007-detail1-9f2481707c-1024x683.webp\" class=\"wp-image-22133\" alt=\"AI-generated stock image of installed memory modules and empty slots in an open server.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-ddr5-speicherbestueckung-256fd007-detail1-9f2481707c-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-ddr5-speicherbestueckung-256fd007-detail1-9f2481707c-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-ddr5-speicherbestueckung-256fd007-detail1-9f2481707c-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-ddr5-speicherbestueckung-256fd007-detail1-9f2481707c-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/server-ddr5-speicherbestueckung-256fd007-detail1-9f2481707c.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-generated stock image: The actual RAM configuration must match the approved server configuration.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For NVMe drives and network cards, the <strong style=\"font-weight:700;color:inherit\">PCIe connection<\/strong> Crucial. AMD specifies up to 128 PCIe 5.0 lanes for single-socket systems and up to 160 for dual-socket servers. The actual number of ports provided by a specific board depends on the platform design and how the connections are used; the 2P maximum does not automatically apply to a 1P host. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">When configuring the system, it\u2019s therefore worth considering how these components interact: Multiple NVMe drives may require additional ports, while high-speed network cards must also be connected. CXL 2.0 is one of the platform capabilities, but it is not a feature that is automatically available on every server. Device, firmware, and operating system support must be verified for the selected system. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"modellvergleich\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"modellvergleich\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Compare Turin hosting plans<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The EPYC 9005 family offers different areas of focus: The 9965 prioritizes maximum core density, while the 9575F aims for a higher clock speed. When making a selection, it\u2019s not just the CPU that matters, but the combination of the specific model, socket type, and application workload. The following table compares four models based on AMD data. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"A Comparison of Four EPYC-9005 Models; Boost Clocks Shown as Maximum Single-Core Values\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">A Comparison of Four EPYC-9005 Models; Boost Clocks Shown as Maximum Single-Core Values<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Model<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Zen Variation<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Cores \/ Threads<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Base \/ Maximum Boost<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">L3 Cache \/ TDP<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Base Operation<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">EPYC 9965<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Zen 5c<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">192 \/ 384<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">2.25 \/ 3.7 GHz<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">384 MB \/ 500 W<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">1P or 2P<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">EPYC 9755<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Zen 5<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">128 \/ 256<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">2.7 \/ 4.1 GHz<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">512 MB \/ 500 W<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">1P or 2P<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">EPYC 9655P<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Zen 5<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">96 \/ 192<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">2.6 \/ 4.5 GHz<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">384 MB \/ 400 W<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">only 1P<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">EPYC 9575F<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Zen 5<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">64 \/ 128<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">3.3 \/ 5.0 GHz<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">256 MB \/ 400 W<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">1P or 2P<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The 9965 provides a particularly large number of physical cores for independent tasks. This can be advantageous for a highly parallelized VM mix, provided that memory and I\/O can keep up. The 9755 offers fewer cores but a higher maximum boost and more total L3 cache. Based on this data alone, there is no definitive ranking for hosting applications. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The 9575F is a possible alternative when individual steps require fast response times. Its <strong style=\"font-weight:700;color:inherit\">maximum boost<\/strong> However, this does not guarantee a sustained clock speed for all cores. Whether it is more cost-effective than a model with more cores depends, among other things, on concurrent requests and the licensing model. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">With the 9655P, this limits the <strong style=\"font-weight:700;color:inherit\">P suffix<\/strong> its suitability for single-socket systems. This model is therefore not an option for a dual-socket server. A more comprehensive platform comparison should include specific configurations and measurements; the article on <a href=\"https:\/\/webhosting.de\/en\/amd-epyc-or-intel-xeon-web-hosting\/\">Choosing Between AMD EPYC and Intel Xeon Platforms<\/a> Further guidance. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"workloads-engpaesse\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"workloads-engpaesse\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Mapping Hosting Workloads and Bottlenecks<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A server CPU must be compatible with the services running simultaneously. In shared hosting, there are many independent requests; in virtual machines, entire operating systems compete for resources; and databases are sensitive to memory accesses or storage latency, depending on the workload. The following overview translates these differences into design criteria. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Hosting Workloads: Requirements, Potential Bottlenecks, and Metrics\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Hosting Workloads: Requirements, Potential Bottlenecks, and Metrics<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Workload<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">CPU Requirements<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Other potential bottlenecks<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Test variables<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">shared hosting<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Concurrent Requests and Short Individual Requests<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Database, RAM, Storage I\/O<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Throughput, response time distribution, error rate<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">VM Hosting<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Virtual CPUs active at the same time<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">RAM Capacity, Memory Bandwidth, Networking, and Storage<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">CPU utilization, wait times, VM response times<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Databases<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Concurrent Queries and Processing of Individual Transactions<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Cache Usage, RAM, Memory Bandwidth, and I\/O<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Transaction throughput, query latency, I\/O latency<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For shared hosting, the number of simultaneously active workers is just as important as the duration of individual requests. High CPU utilization may be acceptable if throughput is good; however, it does not, on its own, indicate whether customers are experiencing long wait times. Therefore, response time distributions and error rates at defined load levels should be included in the comparison.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">When it comes to databases, the <strong style=\"font-weight:700;color:inherit\">L3 Cache<\/strong> Just part of the picture. The 9755 has a total of 512 MB, while the 9965 has a total of 384 MB. These model specifications do not prove any database advantage: record size, access patterns, workload distribution, and RAM configuration all influence how frequently data from other storage levels is required. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A managed Redis service complements the application mix\u2014for example, as a cache. To do this, providers must consider not only CPU resources but, in particular, the available memory and the specific requirements of the service. The article on <a href=\"https:\/\/webhosting.de\/en\/redis-8-new-features-hosting-providers\/\">Redis 8 and Upgrade Decisions for Hosting Providers<\/a> covers, among other things, storage limits and the operation of such services.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">To ensure a fair comparison of models, the VM mix, RAM configuration, storage, and load levels should be kept as comparable as possible. Otherwise, differences in response times or throughput cannot be meaningfully attributed to the choice of CPU. Furthermore, faster individual query response times and higher overall throughput are separate objectives that can be weighted differently in pricing plans.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"vm-kapazitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"vm-kapazitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Planning VM Capacity: An Example<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A theoretical example illustrates the scale: A host with an EPYC 9965 has 192 physical cores and 384 threads. If 48 VMs, each with four vCPUs, are set up on it, this results in 48 \u00d7 4 = 192 allocated vCPUs. This is an allocation calculation and not a measurement of achievable VM performance. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A <strong style=\"font-weight:700;color:inherit\">vCPU<\/strong> This does not automatically mean an exclusively reserved physical core. The hypervisor schedules virtual processors on available logical processors; actual execution depends on which VMs are running simultaneously and what resources are allocated to them. Furthermore, the processor\u2019s 384 threads do not correspond to 384 independent physical cores.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For the <strong style=\"font-weight:700;color:inherit\">Overbooking<\/strong> First, you should determine what concurrent load you expect and what performance a plan promises. A higher number of allocated vCPUs can work when peak loads rarely coincide, but it increases the risk of wait times when many guests are computing at the same time. Test this assumption using your actual customer mix rather than relying solely on the number of threads.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/vm-kapazitaet-reserven-illustration-256fd007-detail2-565da4edb0-1024x683.webp\" class=\"wp-image-22135\" alt=\"AI-generated illustration of virtual machines as containers on a shared platform with space reserved for future expansion.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/vm-kapazitaet-reserven-illustration-256fd007-detail2-565da4edb0-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/vm-kapazitaet-reserven-illustration-256fd007-detail2-565da4edb0-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/vm-kapazitaet-reserven-illustration-256fd007-detail2-565da4edb0-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/vm-kapazitaet-reserven-illustration-256fd007-detail2-565da4edb0-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/11\/vm-kapazitaet-reserven-illustration-256fd007-detail2-565da4edb0.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-generated illustration: When planning virtual machines, reserves must be taken into account in addition to allocated resources.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Next, calculate the memory requirements separately: Add up the planned RAM for the VMs and also factor in the hypervisor\u2019s requirements as well as operational reserves. The CPU calculation does not indicate whether the host provides enough RAM or whether the required memory bandwidth is sufficient when multiple guests are active simultaneously.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The same applies to storage and networking. Many VMs can access NVMe drives or transfer data simultaneously; in this context, I\/O latencies and peak loads are just as important as overall throughput. Therefore, be sure to factor in the connectivity and performance of the drives and network cards that will actually be used.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">After all, you need a reserve for maintenance and outages. If a remaining host is to take on additional VMs after another one fails, the regular utilization must not already be consuming all the resources needed for that. The example with 48 VMs does not specify either a safe utilization limit or a consolidation ratio; both must be evaluated based on the specific environment.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"plattform-inbetriebnahme\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"plattform-inbetriebnahme\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Preparing the Platform and Virtualization<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Start platform planning by identifying the specific CPU model and determining whether one or two sockets are needed. The requirements for cores, RAM, and I\/O must collectively fit within the desired host system. A P-model such as the EPYC 9655P is designed for a single socket and is therefore not suitable for a two-socket configuration. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Next, check the <strong style=\"font-weight:700;color:inherit\">Manufacturer Approval<\/strong> for the CPU, motherboard, and BIOS. Although Turin uses the SP5 socket, an existing SP5 server does not support every 9005 model simply because of that. The power supply and cooling system must also be certified for the selected CPU and the intended chassis. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Plan the RAM modules based on capacity, channel configuration, and the server manufacturer\u2019s specifications. In addition, consider the required NVMe drives and network cards: What matters is not only their number but also which slots or drive bays are connected in the specific system. This allows you to determine before placing an order whether the desired combination is even possible on the platform. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">For confidential customer VMs, you can <strong style=\"font-weight:700;color:inherit\">SEV-SNP<\/strong> Supplement VM memory protection with integrity mechanisms. Trusted I\/O via TDISP is another potential component for device access. Whether this results in a usable solution, however, depends on the combination of firmware, hypervisor, guest operating system, and, if applicable, devices. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Before committing to a product, you should also clarify how guests are set up, certified, and managed, and what restrictions apply to the VM features offered. A single CPU feature does not guarantee the compatibility of the entire stack, nor does it protect against all attacks. Therefore, document the configuration that is actually supported and keep it up to date with any updates. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"betrieb-fehlersuche\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"betrieb-fehlersuche\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Measure Operations and Identify Bottlenecks<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">To compare it with existing hosting hardware, you'll need a clear <strong style=\"font-weight:700;color:inherit\">load profile<\/strong>: roughly the same VM mix, comparable data volumes, and defined query types. Document the RAM configuration, storage, network, and software configuration. This is the only way to determine later whether a deviation is more likely related to the CPU or to another change in the system.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Test multiple load levels rather than just a single peak value. Record throughput, response time distribution, and error rates: Higher throughput is of little value for a hosting service if, at the same time, many requests become slow or fail. Determine in advance which response times and error rates are acceptable for the respective service.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Monitor RAM usage and memory behavior, as well as storage and network latency and utilization, simultaneously. If response times increase even though the CPU still has capacity to spare, another part of the platform may be the bottleneck. Conversely, high CPU utilization alone does not necessarily mean that customers are having a poor user experience.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">If VM response times are unusually long, check the assumed concurrency and the <strong style=\"font-weight:700;color:inherit\">CPU Overbooking<\/strong>. Next, compare the actual RAM configuration, firmware, and hypervisor settings with the planned configuration. Change individual factors as selectively as possible and repeat the same load level so that the cause is not confused with a workload that was changed at the same time. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Ongoing operations also include security bulletins, firmware maintenance, access controls, and verifiable backups. AMD also publishes advisories regarding security vulnerabilities and mitigation measures for EPYC processors; operators must schedule appropriate updates from the server manufacturer. After maintenance, verify once again that security features and the available guest configurations are functioning as intended. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"beschaffung-entscheidung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"beschaffung-entscheidung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Procurement and Cost-Effectiveness Are the Deciding Factors<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A procurement decision begins with the question of whether the existing platform still meets the requirements. If capacity and reserves are sufficient, continuing to operate it may make sense. For an upgrade to Turin, however, the specific CPU model, firmware, and other components must be approved by the server manufacturer; the shared SP5 socket alone is not sufficient proof. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Compare one <strong style=\"font-weight:700;color:inherit\">1P Host<\/strong> with a 2P configuration based on the total requirements for cores, RAM, and ports. Two sockets are not required solely because of a high target number of VMs. Conversely, a single-socket platform may be ruled out if the required combination of memory and I\/O cannot be accommodated in the selected server.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">When dealing with many independent, concurrently running tasks, core density can be an important selection criterion. For latency-sensitive applications, however, it\u2019s worth also evaluating models with higher clock speeds within your own application mix. In addition, calculate the specific licensing model: costs per core, socket, or VM can alter the economic ranking of the platforms.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">The <strong style=\"font-weight:700;color:inherit\">TDP<\/strong> This is not a measurement of the power consumption of an entire server. AMD specifies a TDP of 500 watts for both the EPYC 9755 and the 9965; this does not indicate either the power consumption under your workload or the annual energy costs. RAM, drives, networking, and cooling are all part of the overall system analysis. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">To compare energy and costs, evaluate the entire system at representative load levels and factor in the required reserves. You should compare the costs of acquisition, software licenses, and operation over the planned useful life. Without comparable historical data, it is not possible to promise specific savings or a reliable consolidation rate.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Sources and Current State of Knowledge<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Status of the research: <time datetime=\"2026-11-04\">2026-11-04<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">As of November 4, 2026. EPYC Turin refers to the 9005 series introduced in 2024. Verify model and platform approvals again prior to procurement.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/en\/newsroom\/press-releases\/2024-10-10-amd-launches-5th-gen-amd-epyc-cpus-maintaining-le.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/content\/dam\/amd\/en\/documents\/epyc-business-docs\/datasheets\/amd-epyc-9005-series-processor-datasheet.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.amd.com\/api\/khub\/documents\/UIqhAbjRhgnzgzzdVU4pUw\/content<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/content\/dam\/amd\/en\/documents\/epyc-technical-docs\/tuning-guides\/58466-amd-epyc-9005-tg-cloud-datacenter.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/content\/dam\/amd\/en\/documents\/epyc-technical-docs\/user-guides\/58462_amd-epyc-9005-tg-architecture-overview.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/en\/developer\/sev.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/en\/resources\/product-security\/bulletin\/amd-sb-3023.html<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>AMD EPYC Turin offers hosting providers models with different priorities in terms of core density and clock speed. In addition to the CPU, RAM, I\/O, capacity, and the licensing model are also key factors in the selection process.<\/p>","protected":false},"author":1,"featured_media":22131,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[676],"tags":[],"class_list":["post-22123","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-server_vm"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/posts\/22123","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/comments?post=22123"}],"version-history":[{"count":3,"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/posts\/22123\/revisions"}],"predecessor-version":[{"id":22136,"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/posts\/22123\/revisions\/22136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/media\/22131"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/media?parent=22123"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/categories?post=22123"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/en\/wp-json\/wp\/v2\/tags?post=22123"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}