{"id":21708,"date":"2026-09-25T10:03:34","date_gmt":"2026-09-25T08:03:34","guid":{"rendered":"https:\/\/webhosting.de\/?p=21708"},"modified":"2026-09-25T10:03:37","modified_gmt":"2026-09-25T08:03:37","slug":"alojamiento-web-con-amd-epyc-o-intel-xeon","status":"publish","type":"post","link":"https:\/\/webhosting.de\/es\/amd-epyc-oder-intel-xeon-webhosting\/","title":{"rendered":"AMD EPYC o Intel Xeon: c\u00f3mo elegir la plataforma adecuada para el alojamiento web"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">En lo que respecta al alojamiento web, no hay un ganador claro entre AMD EPYC e Intel Xeon. <strong style=\"font-weight:700;color:inherit\">La plataforma adecuada se adapta al perfil de carga<\/strong>: En el alojamiento compartido, lo que cuenta es la densidad de n\u00facleos y los l\u00edmites, as\u00ed como el rendimiento por trabajador activo en aplicaciones din\u00e1micas, mientras que los VPS y los nodos de bases de datos requieren sobre todo memoria RAM, disposici\u00f3n NUMA y topolog\u00eda de E\/S. Por lo tanto, compara modelos concretos de EPYC 9005 y Xeon 6, junto con la plataforma de servidor, bas\u00e1ndote en mediciones reproducibles en lugar de en el n\u00famero de n\u00facleos, la frecuencia de reloj o pruebas de rendimiento aisladas.   <\/p>\n<nav class=\"wh-toc\" aria-label=\"Contenido de este art\u00edculo\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">Ir directamente a la secci\u00f3n<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#hosting-profile\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Perfiles de alojamiento antes de la comparaci\u00f3n de CPU<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#plattformen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Situar el EPYC 9005 y el Xeon 6 como referencia para la comparaci\u00f3n<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#ressourcen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Las semillas son solo un factor<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#workload-matrix\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Sincronizar las cargas de trabajo con la plataforma<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#benchmark-protokoll\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Planificar correctamente las pruebas de rendimiento de la CPU para el alojamiento web<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#konfigurationscheck\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Comprobar la configuraci\u00f3n y la topolog\u00eda<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#virtualisierung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Gestionar la virtualizaci\u00f3n de forma segura y planificada<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#fehlerquellen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Fuentes de error en la comparaci\u00f3n y el funcionamiento<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#entscheidung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Tomar decisiones de adquisici\u00f3n basadas en requisitos cuantificables<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"hosting-profile\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"hosting-profile\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Perfiles de alojamiento antes de la comparaci\u00f3n de CPU<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">El alojamiento web no supone una carga de trabajo uniforme para la CPU. Una plataforma con miles de cuentas peque\u00f1as se rige por reglas distintas a las de un nodo para m\u00e1quinas virtuales o un servidor de bases de datos. Por lo tanto, antes de comparar AMD EPYC e Intel Xeon, deben determinarse el perfil de consultas, el n\u00famero de clientes activos simult\u00e1neamente, los requisitos de RAM, las E\/S de almacenamiento y los tiempos de respuesta aceptables. Solo esta combinaci\u00f3n hace que los datos t\u00e9cnicos de una CPU sean relevantes a la hora de realizar la adquisici\u00f3n.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><strong style=\"font-weight:700;color:inherit\">alojamiento compartido<\/strong> Procesa numerosas tareas independientes entre s\u00ed de PHP, CMS y correo electr\u00f3nico, que a menudo presentan picos de carga breves. Una alta densidad de n\u00facleos puede ser de ayuda, pero es igualmente importante establecer l\u00edmites eficaces para el tiempo de CPU, los procesos, la memoria RAM y las E\/S. Sin estos l\u00edmites, una sola cuenta puede acaparar los escasos recursos y empeorar los tiempos de respuesta de otros clientes. En este caso, una segregaci\u00f3n planificada de clientes suele ser m\u00e1s importante que un valor m\u00e1ximo obtenido en una prueba sint\u00e9tica de m\u00faltiples n\u00facleos.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de los CMS y las tiendas online gestionados, los requisitos son m\u00e1s variados. Las solicitudes din\u00e1micas de PHP, la cach\u00e9 de objetos, las consultas a la base de datos, las tareas programadas y los accesos de administraci\u00f3n se producen, en ocasiones, simult\u00e1neamente. Para unas pocas aplicaciones exigentes, se puede <strong style=\"font-weight:700;color:inherit\">Rendimiento por n\u00facleo<\/strong> ser m\u00e1s importante que el n\u00famero m\u00e1ximo de n\u00facleos; en cambio, cuando hay un gran n\u00famero de trabajadores PHP-FPM independientes de forma permanente, el paralelismo cobra mayor importancia. Lo decisivo sigue siendo que el servidor web, los procesos PHP y la base de datos est\u00e9n dimensionados adecuadamente.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una tienda de WooCommerce ilustra claramente esta distinci\u00f3n: un servidor web con cach\u00e9 puede servir im\u00e1genes est\u00e1ticas de productos de forma muy eficiente. Sin embargo, el carrito de la compra, el proceso de pago y el stock generan ejecuciones personalizadas de PHP y accesos a la base de datos. Un mayor n\u00famero de n\u00facleos de CPU no elimina el tiempo de espera si las consultas carecen de \u00edndices, el buffer pool es demasiado peque\u00f1o o la latencia de NVMe aumenta bajo carga. Por ello, la latencia de las solicitudes, los tiempos de la base de datos y los tiempos de espera de E\/S deben registrarse por separado.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Los nodos VPS y en la nube necesitan, adem\u00e1s de capacidad de c\u00e1lculo, sobre todo suficiente RAM, ancho de banda de almacenamiento, red y una distribuci\u00f3n de recursos transparente. El \u00abCPU-pinning\u00bb, la memoria reservada, la asignaci\u00f3n NUMA y la calidad de servicio (QoS) del almacenamiento influyen m\u00e1s en la experiencia de los usuarios que el logotipo del fabricante. Los sistemas relacionados con bases de datos, Redis y almacenamiento valoran adem\u00e1s el conjunto de trabajo, el tama\u00f1o de la cach\u00e9, la carga de escritura y la conexi\u00f3n directa a unidades SSD NVMe. En este caso, es importante contar con una configuraci\u00f3n equilibrada <strong style=\"font-weight:700;color:inherit\">Topolog\u00eda de la plataforma<\/strong> a menudo m\u00e1s determinante que el mero valor de rendimiento de un servidor web.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"plattformen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"plattformen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Situar el EPYC 9005 y el Xeon 6 como referencia para la comparaci\u00f3n<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Este art\u00edculo compara deliberadamente AMD EPYC 9005 e Intel Xeon 6 como generaciones de plataformas claramente diferenciadas. Esta comparaci\u00f3n tiene como objetivo facilitar la adquisici\u00f3n, ampliaci\u00f3n o evaluaci\u00f3n de sistemas basados en estas dos familias de productos. No se pueden extraer conclusiones sobre otras generaciones o l\u00edneas de productos, ya que la estructura de los n\u00facleos, la plataforma de memoria, las caracter\u00edsticas de E\/S y las funciones disponibles pueden variar.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Adem\u00e1s, una funci\u00f3n del procesador documentada se distingue de una que realmente <strong style=\"font-weight:700;color:inherit\">sistema de servidores disponible<\/strong> Hay que tener en cuenta que la placa base, el firmware, la configuraci\u00f3n de los m\u00f3dulos DIMM, la refrigeraci\u00f3n, las fuentes de alimentaci\u00f3n y las homologaciones de los fabricantes de equipos originales (OEM) determinan qu\u00e9 configuraci\u00f3n es viable en la pr\u00e1ctica. Por lo tanto, comprueba para cada SKU concreta qu\u00e9 modelos de servidor est\u00e1n disponibles y han sido validados para la configuraci\u00f3n prevista. Esto es especialmente importante en el caso de grandes capacidades de RAM, numerosas unidades NVMe y funciones especiales de virtualizaci\u00f3n.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Las generaciones anteriores de EPYC 700x y los modelos anteriores de Xeon Scalable no deben mezclarse sin m\u00e1s con los EPYC 9005 o los Xeon 6. Tampoco se deben extrapolar a estas familias los datos de otras l\u00edneas de productos. La estructura de n\u00facleos, el equipamiento de E\/S, la plataforma de memoria y las funciones disponibles pueden variar de una generaci\u00f3n a otra. Por lo tanto, para realizar una comparaci\u00f3n de compras siempre es necesario disponer de la denominaci\u00f3n completa del modelo, el n\u00famero de z\u00f3calos y la placa base del servidor utilizada.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La serie EPYC 9005 incluye, seg\u00fan el modelo, procesadores con <strong style=\"font-weight:700;color:inherit\">Zen 5<\/strong>\u2013 o n\u00facleos Zen-5c. Estas denominaciones no describen una clasificaci\u00f3n general para el alojamiento web. Lo que realmente importa es la SKU concreta, el n\u00famero de n\u00facleos, la frecuencia de reloj, los requisitos t\u00e9rmicos y el nivel de paralelismo previsto. Una variante con muchos n\u00facleos puede ser adecuada para numerosos clientes bien delimitados, mientras que un modelo con caracter\u00edsticas diferentes puede resultar m\u00e1s adecuado para un n\u00famero menor de aplicaciones que requieren un mayor poder de c\u00e1lculo. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Intel divide la gama Xeon 6 en variantes con n\u00facleos P y n\u00facleos E. Los n\u00facleos P est\u00e1n orientados a un alto rendimiento por n\u00facleo y son compatibles, entre otras cosas, con AVX-512 y AMX. Esto puede resultar relevante si el software utilizado aprovecha realmente estas funciones vectoriales o matriciales; una pila habitual de PHP o de servidor web no obtiene autom\u00e1ticamente ninguna ventaja de ello. Los n\u00facleos E, por su parte, se centran en una alta densidad de n\u00facleos y en el rendimiento paralelo. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Por lo tanto, para cargas de trabajo compartidas o en la nube muy densas y bien aisladas, los n\u00facleos Xeon 6-E pueden ser, en principio, una opci\u00f3n a tener en cuenta. Los n\u00facleos Xeon 6-P o los modelos EPYC 9005 debidamente configurados tambi\u00e9n son candidatos obvios para cargas de trabajo que requieran un mayor rendimiento por n\u00facleo. Se trata de una clasificaci\u00f3n de la orientaci\u00f3n del producto, no de una garant\u00eda de rendimiento. La ampliaci\u00f3n de la memoria RAM, el firmware y la configuraci\u00f3n del software pueden influir de manera significativa en el resultado y sesgar una comparaci\u00f3n entre los distintos tipos de n\u00facleos si la configuraci\u00f3n de la plataforma no es id\u00e9ntica.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"ressourcen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"ressourcen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Las semillas son solo un factor<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Los n\u00facleos de la CPU solo aportan todo su potencial si la memoria y las E\/S est\u00e1n a la altura. Los canales DDR5, junto con la configuraci\u00f3n y el tipo de m\u00f3dulo DIMM, determinan el ancho de banda de memoria disponible; por el contrario, la capacidad de la RAM limita el n\u00famero de m\u00e1quinas virtuales, b\u00faferes de bases de datos o cach\u00e9s que pueden funcionar sin necesidad de paginaci\u00f3n. Los carriles PCIe conectan unidades NVMe, tarjetas de red y, en su caso, aceleradores. Para el alojamiento web, esta cadena debe planificarse como un sistema integral.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">AMD especifica para el EPYC 9005 hasta doce canales DDR5, as\u00ed como, en funci\u00f3n del n\u00famero de z\u00f3calos y de la plataforma, una amplia conectividad PCIe Gen 5. Para los sistemas de un solo z\u00f3calo, se indican hasta 128 carriles PCIe Gen 5. Intel Xeon 6 tambi\u00e9n ofrece, seg\u00fan la serie, hasta doce canales DDR5; algunas configuraciones seleccionadas de un solo z\u00f3calo con n\u00facleos P alcanzan hasta 136 carriles PCIe. Estos valores corresponden a datos de modelos y plataformas, y no constituyen una garant\u00eda del rendimiento de una aplicaci\u00f3n.  <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-1024x683.webp\" class=\"wp-image-21714\" alt=\"Topolog\u00eda esquem\u00e1tica de la plataforma con CPU, memoria RAM, unidades NVMe y tarjetas de red.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Los canales de memoria y las rutas PCIe influyen en que la capacidad de la CPU se pueda aprovechar en el alojamiento web.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un nodo VPS con varios SSD NVMe, dos tarjetas de red de alta velocidad y numerosas m\u00e1quinas virtuales pone de manifiesto la diferencia en la pr\u00e1ctica. Si las unidades o las tarjetas de red est\u00e1n conectadas a trav\u00e9s de conmutadores PCIe, es posible que compartan un enlace ascendente. La placa base tambi\u00e9n determina la distribuci\u00f3n de carriles, las ranuras, la bifurcaci\u00f3n, la compatibilidad con CXL y la configuraci\u00f3n de firmware realmente habilitada. Por lo tanto, la capacidad de la CPU documentada debe cotejarse con el diagrama de bloques y la validaci\u00f3n del servidor concreto. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En los sistemas con varios nodos NUMA, tambi\u00e9n es fundamental d\u00f3nde se asignan la memoria RAM, las CPU virtuales y los dispositivos de E\/S. Si una m\u00e1quina virtual o una base de datos accede con frecuencia a la memoria de otro nodo, pueden producirse latencias adicionales. Por lo tanto, es recomendable realizar mediciones en condiciones de carga realistas: la carga de la CPU por s\u00ed sola no revela ni los cuellos de botella en la memoria ni las colas en el almacenamiento o la red.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Muchos canales facilitan la conexi\u00f3n directa de numerosos dispositivos, pero no garantizan ni una baja latencia de la base de datos ni altas tasas de transacci\u00f3n. El controlador, el firmware del SSD, el dise\u00f1o RAID o de replicaci\u00f3n, la profundidad de la cola y la ruta de red siguen siendo factores determinantes. La elecci\u00f3n entre <strong style=\"font-weight:700;color:inherit\">Alojamiento AMD EPYC<\/strong> Por lo tanto, en el caso de un servidor Intel Xeon, deber\u00eda tener en cuenta los requisitos de E\/S y memoria con la misma precisi\u00f3n que el n\u00famero de n\u00facleos y la frecuencia de reloj.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"workload-matrix\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"workload-matrix\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Sincronizar las cargas de trabajo con la plataforma<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La elecci\u00f3n no empieza por el fabricante, sino por la distribuci\u00f3n de la carga. El Xeon 6 con n\u00facleos E suele ser adecuado para un gran n\u00famero de tareas independientes entre s\u00ed y claramente delimitadas; el Xeon 6 con n\u00facleos P, para requisitos de <strong style=\"font-weight:700;color:inherit\">Rendimiento por n\u00facleo<\/strong> y determinadas operaciones vectoriales o matriciales. El EPYC 9005 tambi\u00e9n ofrece diferentes perfiles de n\u00facleos y frecuencias de reloj. De ello no se deriva ninguna clasificaci\u00f3n: lo decisivo es la referencia concreta, la topolog\u00eda del servidor y la carga de trabajo de la aplicaci\u00f3n medida.   <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Criterios de selecci\u00f3n seg\u00fan la carga de trabajo del alojamiento\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Criterios de selecci\u00f3n seg\u00fan la carga de trabajo del alojamiento<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Carga de trabajo<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Criterio m\u00e1s importante de la CPU<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Criterio m\u00e1s importante de la plataforma<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Cuellos de botella t\u00edpicos<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Valores de medici\u00f3n necesarios<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">alojamiento compartido<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Alto nivel de paralelismo con l\u00edmites de cuenta eficaces<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">RAM por cuenta, programador y l\u00edmites de E\/S<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Algunas cuentas consumen recursos de CPU, RAM o E\/S de disco<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Tiempo de respuesta p95, procesos activos, cola de ejecuci\u00f3n, limitaci\u00f3n de la CPU y tiempo de espera de E\/S; \u00absteal time\u00bb solo en el caso de un host virtualizado<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">CMS y tiendas online<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Rendimiento por trabajador PHP activo, adem\u00e1s de un nivel adecuado de paralelismo<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Cach\u00e9 de objetos r\u00e1pida, RAM de base de datos y latencia NVMe<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Colas de PHP-FPM, consultas lentas, fallos de cach\u00e9<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">p95\/p99: tiempo de solicitud, carga de trabajo de los trabajadores, tiempo de consulta, tasa de aciertos en la cach\u00e9<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">VPS y la nube<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Densidad de n\u00facleos o rendimiento garantizado por vCPU seg\u00fan la tarifa<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Dise\u00f1o NUMA, capacidad de RAM, red y calidad de servicio (QoS) del almacenamiento<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Sobrecarga de la CPU, asignaci\u00f3n desigual de la RAM, competencia por el almacenamiento<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Latencia de hu\u00e9sped, IOPS, rendimiento, latencia de red, as\u00ed como \u2014dependiendo del hipervisor\u2014 tiempo de disponibilidad de la CPU, cola de ejecuci\u00f3n, tiempo de intermisi\u00f3n o m\u00e9tricas de programaci\u00f3n similares<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Base de datos y Redis<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Rendimiento de la cach\u00e9 y de la memoria, en funci\u00f3n del paralelismo<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Ampliaci\u00f3n de DDR5, afinidad NUMA y conexi\u00f3n directa al almacenamiento<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Falta de RAM, accesos NUMA remotos, NVMe lento o sobrecargado<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Latencia de consultas o comandos, aciertos en el pool de b\u00faferes, latencia de E\/S, ancho de banda de memoria<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Servicios relacionados con NVMe<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">CPU con capacidad suficiente para la carga de protocolos y pruebas<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Topolog\u00eda PCIe, n\u00famero de conexiones directas a unidades de disco y tarjetas de red<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Conmutadores PCIe, colas, l\u00edmites de red o de replicaci\u00f3n<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">p99: latencia de E\/S, profundidad de cola, IOPS, rendimiento, carga de red<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el alojamiento compartido, una alta densidad de n\u00facleos solo resulta \u00fatil si los l\u00edmites de tiempo de CPU, procesos, memoria RAM y E\/S protegen realmente a las cuentas vecinas. Por lo tanto, los modelos E-Core pueden ser adecuados para entornos de clientes altamente paralelizados. Un modelo EPYC 9005 con el perfil de n\u00facleos adecuado tambi\u00e9n puede ser una buena opci\u00f3n. Por el contrario, para instancias individuales exigentes de tiendas online o CMS, los tiempos de respuesta por trabajador y la base de datos son m\u00e1s importantes que el mero n\u00famero de n\u00facleos disponibles.   <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Los nodos VPS y los servicios relacionados con el almacenamiento requieren, adem\u00e1s, una comprobaci\u00f3n de la <strong style=\"font-weight:700;color:inherit\">Topolog\u00eda de E\/S<\/strong>. El EPYC 9005 cuenta con amplios recursos de DDR5 y PCIe 5.0, dependiendo de la plataforma; el Xeon 6 tambi\u00e9n ofrece canales de memoria y carriles PCIe que var\u00edan seg\u00fan la serie y el modelo. Estos datos facilitan la preselecci\u00f3n, pero no garantizan ni una latencia NVMe concreta ni un rendimiento espec\u00edfico de la base de datos. La placa base, la configuraci\u00f3n, el firmware y la ruta de software siguen siendo factores determinantes en la decisi\u00f3n.   <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"benchmark-protokoll\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"benchmark-protokoll\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Planificar correctamente las pruebas de rendimiento de la CPU para el alojamiento web<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">El t\u00e9rmino de b\u00fasqueda <strong style=\"font-weight:700;color:inherit\">pruebas de rendimiento de la CPU en servidores de alojamiento<\/strong> da lugar a una simplificaci\u00f3n inadmisible: un resultado de la CPU no describe una oferta de alojamiento. SPEC considera los resultados como los de sistemas completos y exige que se revelen los detalles esenciales de la configuraci\u00f3n. Por lo tanto, para realizar una comparaci\u00f3n entre plataformas, es necesario probar ambos candidatos con un n\u00famero comparable de z\u00f3calos, memoria, almacenamiento, red y software.  <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Protocolo de pruebas comparativas reproducible para plataformas de alojamiento\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Protocolo de pruebas comparativas reproducible para plataformas de alojamiento<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Objetivo de la prueba<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Generador de carga o herramienta<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Variable medida<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Datos obligatorios sobre el entorno<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Criterios de exclusi\u00f3n<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">PHP-FPM y el servidor web<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Carga HTTP representativa con rutas anonimizadas y tiempos de respuesta realistas<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Solicitudes por segundo, latencia p95\/p99, tasa de errores<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Modelo de CPU, RAM, NVMe, red, sistema operativo, kernel, servidor web, versi\u00f3n de PHP y grupos de FPM<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Solo respuestas est\u00e1ticas, cach\u00e9s diferentes o l\u00edmites de trabajadores distintos<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Base de datos<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Consultas orientadas a la aplicaci\u00f3n y volumen de datos definido<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Tiempo de consulta, transacciones, latencia p95\/p99, tiempo de espera de E\/S<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Adem\u00e1s: versi\u00f3n de la base de datos, par\u00e1metros, grupo de b\u00faferes, \u00edndices, tama\u00f1o de los registros y modo de replicaci\u00f3n<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Cach\u00e9 en caliente solo en una plataforma o conjuntos de datos dispares<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Densidad de VPS<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Instances definidas con la misma carga y reserva de recursos<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Latencia del sistema invitado, rendimiento, IOPS, as\u00ed como \u2014en funci\u00f3n del hipervisor y del sistema operativo invitado\u2014 el tiempo de disponibilidad de la CPU, el tiempo de robo, la cola de ejecuci\u00f3n o m\u00e9tricas de programaci\u00f3n similares<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Adem\u00e1s: hipervisor, sistema operativo invitado, asignaci\u00f3n fija de CPU, asignaci\u00f3n NUMA, reserva de RAM y QoS de almacenamiento<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Diferentes \u00edndices de sobreasignaci\u00f3n, topolog\u00eda de vCPU, metodolog\u00eda de medici\u00f3n o carga de fondo del host<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de PHP-FPM, un alto rendimiento de solicitudes no es suficiente. Una plataforma puede proporcionar muchas respuestas con una carga sint\u00e9tica breve y, sin embargo, generar valores p99 elevados cuando se ejecutan tareas cron en paralelo o se realizan consultas lentas a la base de datos. Por lo tanto, registra las colas, las tasas de error y los tiempos de respuesta por separado para las p\u00e1ginas din\u00e1micas y las almacenadas en cach\u00e9. Las implementaciones con control de versiones ayudan a documentar de forma inequ\u00edvoca la aplicaci\u00f3n y la configuraci\u00f3n probadas. <a href=\"https:\/\/webhosting.de\/es\/alojamiento-web-con-soporte-git-mejor-proveedor-2025-code\/\">Flujos de trabajo de Git en el alojamiento web<\/a><\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de las bases de datos, es necesario documentar el tama\u00f1o de los registros y el estado de la cach\u00e9, ya que una prueba que se ejecuta \u00edntegramente en la RAM muestra l\u00edmites distintos a los de un funcionamiento con una carga elevada de E\/S. En el caso de la densidad de VPS, la experiencia en el sistema invitado tambi\u00e9n es determinante. La m\u00e9trica de programaci\u00f3n m\u00e1s relevante depende del hipervisor y del sistema operativo invitado; por lo tanto, el tiempo de CPU Ready no debe considerarse una m\u00e9trica universalmente v\u00e1lida. Repite las pruebas de carga y registra de forma clara el m\u00e9todo de medici\u00f3n y las desviaciones.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"konfigurationscheck\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"konfigurationscheck\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Comprobar la configuraci\u00f3n y la topolog\u00eda<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Antes de realizar una comparaci\u00f3n, debes evaluar primero el estado actual. Esto evita que una supuesta diferencia en el rendimiento de la CPU se deba, en realidad, a una asignaci\u00f3n NUMA diferente, a una memoria RAM distinta o a un cambio en la configuraci\u00f3n del servidor web. Los siguientes comandos leen informaci\u00f3n o comprueban configuraciones; no modifican ni la asignaci\u00f3n de la CPU ni los ajustes de los servicios. Ejec\u00fatalos con los permisos necesarios en cada sistema y guarda los resultados de forma segura.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Con <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">lscpu<\/code> Documenta el modelo de CPU, las CPU l\u00f3gicas, el z\u00f3calo, los n\u00facleos y los nodos NUMA detectados. <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">numactl --hardware<\/code> Si la herramienta est\u00e1 instalada, se a\u00f1aden las CPU y la memoria disponibles por cada nodo NUMA. Ambas salidas describen la topolog\u00eda de hardware detectada, no la carga real bajo la carga de alojamiento. <\/p>\n<div class=\"wh-code-window\" data-wh-code style=\"margin:28px 0 34px;border:1px solid #2c4656;border-radius:12px;overflow:hidden;background:#132a3b;box-shadow:0 9px 25px -13px rgba(15,35,55,.2)\"><div class=\"wh-code-toolbar\" style=\"display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:10px;padding:11px 16px;background:#223e50;color:#edf5fa;font-size:13px;line-height:1.5;font-weight:600\"><span>Terminal<\/span><button type=\"button\" class=\"wh-code-copy\" data-wh-copy hidden style=\"padding:6px 11px;border:1px solid #7893a1;border-radius:6px;background:transparent;color:#fff;font-size:12px;line-height:1.5;font-weight:600;cursor:pointer\">Copiar c\u00f3digo<\/button><span class=\"wh-copy-status\" aria-live=\"polite\"><\/span><span data-wh-copy-success hidden>Copiado<\/span><span data-wh-copy-fallback hidden>C\u00f3digo resaltado: por favor, c\u00f3pialo<\/span><\/div><pre class=\"wh-code\" data-no-translation translate=\"no\" style=\"display:block;margin:0;padding:20px;max-width:100%;overflow-x:auto;color:#edf5fa;background:#132a3b;font:14px\/1.75 ui-monospace,SFMono-Regular,Menlo,Consolas,monospace;white-space:pre;direction:ltr;text-align:left\"><code class=\"language-bash\" style=\"font:inherit;color:inherit;background:transparent;padding:0;border:0;white-space:inherit\">lscpu\nnumactl --hardware\nnginx -T\nphp-fpm -tt<\/code><\/pre><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">El llamamiento <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">nginx -T<\/code> Muestra la configuraci\u00f3n efectiva de NGINX y, por lo tanto, puede contener nombres de host internos, rutas de archivos o referencias a certificados. Comprueba y corrige esos datos antes de compartir la salida. <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">php-fpm -tt<\/code> Es un ejemplo de comprobaci\u00f3n de la configuraci\u00f3n; el nombre del archivo binario y las opciones var\u00edan en funci\u00f3n de la distribuci\u00f3n y la versi\u00f3n de PHP. Comprueba primero la variante disponible localmente, en lugar de modificar una configuraci\u00f3n en producci\u00f3n. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un caso pr\u00e1ctico de VPS ilustra el objetivo: si las vCPU de una m\u00e1quina virtual est\u00e1n asignadas a los n\u00facleos de un nodo NUMA, pero la memoria RAM que tienen reservada se encuentra principalmente en el otro nodo, los accesos a la memoria pueden sufrir una latencia adicional. Por lo tanto, documenta <strong style=\"font-weight:700;color:inherit\">Fijaci\u00f3n de la CPU<\/strong> y la asignaci\u00f3n de RAM. Solo entonces se podr\u00e1 evaluar si es necesaria otra plataforma de CPU o, en un primer momento, una topolog\u00eda de m\u00e1quina virtual m\u00e1s coherente. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"virtualisierung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"virtualisierung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Gestionar la virtualizaci\u00f3n de forma segura y planificada<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de las ofertas de VPS y en la nube, el nombre del procesador no es el \u00fanico factor que determina el rendimiento percibido. <strong style=\"font-weight:700;color:inherit\">Fijaci\u00f3n de la CPU<\/strong> Asigna vCPU a n\u00facleos f\u00edsicos espec\u00edficos seg\u00fan sea necesario, lo que permite reducir las fluctuaciones en los tiempos de ejecuci\u00f3n. Sin embargo, se trata de una decisi\u00f3n de capacidad: los n\u00facleos reservados en exclusiva no est\u00e1n disponibles para una distribuci\u00f3n flexible entre otros clientes. Por lo tanto, en el caso de las tarifas con potencia de c\u00e1lculo garantizada, esta reserva deber\u00eda incluirse en la planificaci\u00f3n de la carga de trabajo.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Igualmente importante es la <strong style=\"font-weight:700;color:inherit\">Afinidad NUMA<\/strong> en sistemas con varios sockets o con un gran n\u00famero de n\u00facleos. Una m\u00e1quina virtual deber\u00eda utilizar, en la medida de lo posible, n\u00facleos y memoria RAM del mismo nodo NUMA. Si accede con frecuencia a la memoria de otro nodo, las rutas de acceso adicionales pueden aumentar la latencia. Por lo tanto, planifica las m\u00e1quinas virtuales de gran tama\u00f1o teniendo en cuenta, en primer lugar, la capacidad de RAM local y la asignaci\u00f3n de n\u00facleos, en lugar de considerar \u00fanicamente la suma de todos los n\u00facleos y de toda la memoria RAM.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-1024x683.webp\" class=\"wp-image-21715\" alt=\"Ejemplo simplificado de varios dominios NUMA con m\u00e1quinas virtuales, n\u00facleos de CPU y memoria asignados localmente.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Los dominios NUMA dependen del procesador, la plataforma y el firmware; una asignaci\u00f3n adecuada puede reducir los accesos remotos innecesarios a la memoria.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La RAM reservada evita que la capacidad de memoria prometida se deba \u00fanicamente a un sobreaprovechamiento optimista. Adem\u00e1s, limita <strong style=\"font-weight:700;color:inherit\">QoS de almacenamiento<\/strong> IOPS, rendimiento o colas por m\u00e1quina virtual, para que una copia de seguridad, una importaci\u00f3n de base de datos o un sistema invitado mal configurado no bloqueen el pool NVMe compartido. Establece l\u00edmites de sobreasignaci\u00f3n por separado para la CPU, la RAM y el almacenamiento: una cuota de CPU viable no hace que un nodo sea escalable si su almacenamiento ya genera tiempos de espera elevados en momentos de m\u00e1xima carga.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para las m\u00e1quinas virtuales confidenciales, ambas plataformas ofrecen funciones que van m\u00e1s all\u00e1 de la virtualizaci\u00f3n habitual. AMD documenta para EPYC 9005 las tecnolog\u00edas SEV, SEV-ES y SEV-SNP; SEV-SNP complementa los mecanismos de protecci\u00f3n contra determinados ataques a las tablas de p\u00e1ginas y a la asignaci\u00f3n de memoria.   Intel describe TDX como una tecnolog\u00eda que a\u00edsla el sistema operativo invitado y las aplicaciones de la m\u00e1quina virtual del host en la nube, el hipervisor y otras m\u00e1quinas virtuales de la plataforma.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Estas funciones no hacen que un servidor AMD EPYC ni un servidor Intel Xeon sean autom\u00e1ticamente m\u00e1s seguros. En el caso de Intel TDX, es necesario comprobar los procesadores compatibles, que el equipo cuente con los m\u00f3dulos DIMM adecuados y la plataforma concreta del fabricante OEM u ODM; los requisitos documentados para los m\u00f3dulos DIMM pueden variar en funci\u00f3n de la implementaci\u00f3n de la plataforma.   Adem\u00e1s, su uso requiere una interacci\u00f3n coordinada entre el firmware, el hipervisor, el n\u00facleo, el sistema operativo invitado y los procesos operativos. Comprueba tambi\u00e9n el ciclo de vida de las claves, la certificaci\u00f3n, la recuperaci\u00f3n y la supervisi\u00f3n. Sin estos procesos, una funci\u00f3n de hardware activada no puede cubrir por completo los requisitos de protecci\u00f3n de un cliente.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"fehlerquellen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"fehlerquellen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Fuentes de error en la comparaci\u00f3n y el funcionamiento<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una comparaci\u00f3n v\u00e1lida debe partir de sistemas del mismo tama\u00f1o. No se puede comparar un servidor con dos z\u00f3calos con un sistema de un solo z\u00f3calo cuando la decisi\u00f3n de adquisici\u00f3n se refiere a una clase de plataforma. Anota, para cada prueba, el modelo de CPU, el n\u00famero de z\u00f3calos, los n\u00facleos activos, la cantidad de RAM y la configuraci\u00f3n de los m\u00f3dulos DIMM. Solo as\u00ed se podr\u00e1 determinar si un resultado se debe a la arquitectura, a hardware adicional o a una configuraci\u00f3n diferente.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Asimismo, una memoria y una E\/S desiguales distorsionan las conclusiones. Las diferencias en la asignaci\u00f3n de canales DDR5, las generaciones de NVMe, la configuraci\u00f3n RAID, las tarjetas de red o los perfiles de energ\u00eda de la BIOS alteran considerablemente el rendimiento y las latencias. AMD se\u00f1ala, en el caso del EPYC 9005, que la configuraci\u00f3n concreta de E\/S depende de la plataforma y de la placa base; por lo tanto, la capacidad de interfaz documentada no constituye una garant\u00eda para la aplicaci\u00f3n.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Aunque un gran n\u00famero de carriles PCIe facilita la conexi\u00f3n directa de varias unidades NVMe y tarjetas de red de alta velocidad, no garantizan una baja latencia de la base de datos: las colas en el almacenamiento, el firmware del controlador, la replicaci\u00f3n, los par\u00e1metros de la base de datos y el conjunto de trabajo en la RAM siguen siendo factores determinantes. En el caso de las arquitecturas cercanas al almacenamiento, el art\u00edculo a\u00f1ade <a href=\"https:\/\/webhosting.de\/es\/iot-webhosting-edge-seguridad-red-comparacion-sociedad-digital\/\">Alojamiento web para plataformas de IoT<\/a> la perspectiva sobre la latencia de la red, la segmentaci\u00f3n y las rutas de almacenamiento.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Las frecuencias \u00abBoost\u00bb aisladas tampoco constituyen un punto de referencia para el alojamiento web. AMD define el \u00abBoost\u00bb m\u00e1ximo como la frecuencia que puede alcanzar un \u00fanico n\u00facleo en condiciones normales de servidor; bajo una carga paralela continua se aplican otras condiciones t\u00e9rmicas y energ\u00e9ticas.   Por lo tanto, se deben evaluar los percentiles de tiempo de respuesta y el rendimiento bajo condiciones representativas de concurrencia, en lugar de deducir el rendimiento de todo un nodo a partir de un \u00fanico valor de frecuencia.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Al fin y al cabo, el TDP no es una medida del consumo real del servidor. Para realizar estimaciones de costes, necesitas valores de medici\u00f3n de todo el sistema con la memoria RAM, el almacenamiento, la carga de red y el perfil energ\u00e9tico seleccionados. El <strong style=\"font-weight:700;color:inherit\">Comparabilidad<\/strong> La publicaci\u00f3n de resultados exige, adem\u00e1s, datos completos sobre el sistema; SPEC considera expresamente los resultados como los de sistemas completos, y no de procesadores individuales.  <\/p>\n<aside class=\"wh-callout wh-callout-warning\" style=\"display:block;margin:28px 0;padding:20px 23px;border:1px solid #d1e4dd;border-left:4px solid #187065;border-radius:11px;background:#f0f7f4\"><p class=\"wh-callout-title\" style=\"margin:0 0 8px;color:#1c5c53;font-size:16px;font-weight:700;line-height:1.5\">Separar claramente los datos de compras<\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Los datos del fabricante sobre rendimiento, consolidaci\u00f3n o TCO se refieren a la configuraci\u00f3n comparativa descrita en cada caso. No los consideres como una previsi\u00f3n general para una pila de alojamiento diferente.<\/p>\n<\/aside><\/section><section class=\"wh-section\" aria-labelledby=\"entscheidung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"entscheidung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Tomar decisiones de adquisici\u00f3n basadas en requisitos cuantificables<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En primer lugar, documenta el perfil de carga: n\u00famero y tama\u00f1o de los clientes, concurrencia t\u00edpica y m\u00e1xima, proporci\u00f3n de PHP o de la aplicaci\u00f3n, consultas a la base de datos, tasa de aciertos de la cach\u00e9, RAM por instancia, as\u00ed como picos de E\/S y de red. De ello no se deriva una clasificaci\u00f3n abstracta, sino un cat\u00e1logo de requisitos. Solo este cat\u00e1logo permite determinar si lo que marca la diferencia es una alta densidad de n\u00facleos, tiempos de respuesta cortos de los trabajadores individuales o una conexi\u00f3n de almacenamiento especialmente amplia.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A continuaci\u00f3n, determina si vas a ampliar una plataforma existente, evaluar sistemas de segunda mano o en stock, o adquirir una configuraci\u00f3n de servidor completamente nueva. En el caso de los modelos EPYC 9005 y Xeon 6, es necesario comprobar la disponibilidad, las autorizaciones de los fabricantes de equipos originales (OEM), el mantenimiento del firmware y la planificaci\u00f3n de piezas de recambio para el modelo de servidor concreto. La denominaci\u00f3n de la familia de CPU por s\u00ed sola no garantiza ni la disponibilidad ni la validaci\u00f3n de los componentes de RAM, almacenamiento y red deseados.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A continuaci\u00f3n, compara las referencias concretas, incluyendo la topolog\u00eda del z\u00f3calo y la plataforma del servidor. En el caso del AMD EPYC 9005, hay que tener en cuenta la variante de n\u00facleos, el modelo y la capacidad prevista de DDR5 y PCIe. La familia incluye modelos Zen 5 y Zen 5c, cuyas caracter\u00edsticas no deben equipararse de forma generalizada.   En el caso de Intel Xeon 6, hay que distinguir especialmente entre las variantes P-Core y E-Core, ya que persiguen objetivos diferentes en cuanto a rendimiento por n\u00facleo y densidad de n\u00facleos.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Comprueba la configuraci\u00f3n como una lista completa de componentes: configuraci\u00f3n validada de los m\u00f3dulos DIMM, RAM local por nodo NUMA, n\u00famero y conexi\u00f3n de las unidades NVMe, tarjetas de red, conmutadores PCIe, as\u00ed como el sistema de refrigeraci\u00f3n y las fuentes de alimentaci\u00f3n. Un <strong style=\"font-weight:700;color:inherit\">Nodo de alojamiento EPYC-9005<\/strong> Es l\u00f3gico que as\u00ed sea cuando una configuraci\u00f3n concreta disponible ofrece la combinaci\u00f3n requerida de n\u00facleos, canales de memoria y E\/S. Se trata de una comprobaci\u00f3n de idoneidad de la SKU y la plataforma de servidor elegidas, no de una ventaja general en cuanto a rendimiento frente a Intel Xeon.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un servidor Intel Xeon 6 con n\u00facleos E puede ser una opci\u00f3n viable para muchas cargas de trabajo bien delimitadas e independientes. Los modelos con n\u00facleos P son m\u00e1s recomendables cuando determinadas aplicaciones requieren un alto rendimiento por n\u00facleo o cuando son relevantes las funciones vectoriales y matriciales adecuadas. Intel menciona AVX-512 y AMX para los n\u00facleos P del Xeon 6; sin embargo, que estas funciones resulten \u00fatiles depende del software utilizado y de su implementaci\u00f3n concreta.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Antes de realizar el pedido, lleva a cabo una prueba reproducible con tus propias im\u00e1genes, configuraciones y vol\u00famenes de datos realistas. Adem\u00e1s de las solicitudes por segundo, registra tambi\u00e9n la tasa de errores, los percentiles de tiempo de respuesta, los tiempos de espera de la base de datos, las latencias de almacenamiento y el comportamiento en caso de copias de seguridad simult\u00e1neas o fallos. Es necesario disponer de informaci\u00f3n completa sobre el hardware y el software para que las decisiones posteriores sean comprensibles.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A <strong style=\"font-weight:700;color:inherit\">Funcionamiento piloto<\/strong> Resulta conveniente cuando la densidad prevista de clientes, las nuevas funciones del hipervisor, un dise\u00f1o NVMe poco habitual o los costes energ\u00e9ticos influyen considerablemente en el c\u00e1lculo. Para ello, utiliza un grupo limitado y representativo de clientes o de prueba, con l\u00edmites claros de recursos. Solo tras observar los picos de carga, las reservas de capacidad y los procesos operativos, se pueden justificar t\u00e9cnicamente las extrapolaciones, la adquisici\u00f3n y la implantaci\u00f3n.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Fuentes y estado actual de los conocimientos<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Estado de la investigaci\u00f3n: <time datetime=\"2026-09-24\">2026-09-24<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Estado t\u00e9cnico: 24 de septiembre de 2026. Este art\u00edculo compara exclusivamente los procesadores AMD EPYC 9005 e Intel Xeon 6; los datos relativos a otras generaciones y gamas de productos deben comprobarse por separado. No deben equipararse la presentaci\u00f3n del producto, las referencias de CPU disponibles y los sistemas de servidor realmente adquiribles y validados. La informaci\u00f3n sobre canales, carriles PCIe y funciones de seguridad depende siempre del modelo y la plataforma. Nota sobre la fuente: en el PDF sobre la serie EPYC 9005 de S2, el t\u00edtulo de los metadatos del PDF incrustado puede aparecer como \u201eAMD EPYC 4004 Series Processors\u201c; sin embargo, la URL, que no ha sido modificada, y el contenido visible del documento se refieren a AMD EPYC 9005.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/products\/docs\/xeon-6-product-brief.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/content\/dam\/amd\/en\/documents\/epyc-business-docs\/datasheets\/amd-epyc-9005-series-processor-datasheet.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.spec.org\/cpu2026\/docs\/runrules.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/content\/dam\/amd\/en\/documents\/epyc-technical-docs\/user-guides\/58462_amd-epyc-9005-tg-architecture-overview.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.amd.com\/api\/khub\/documents\/UIqhAbjRhgnzgzzdVU4pUw\/content<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/cc-enabling.trustedservices.intel.com\/intel-tdx-enabling-guide\/03\/hardware_selection\/<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>No se puede hacer una valoraci\u00f3n generalizada de los procesadores AMD EPYC 9005 e Intel Xeon 6 para el alojamiento web. Los factores decisivos son el modelo de alojamiento, la referencia concreta, la topolog\u00eda de la RAM y de E\/S, la disposici\u00f3n NUMA, as\u00ed como las mediciones con una carga representativa.<\/p>","protected":false},"author":1,"featured_media":21713,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[676],"tags":[],"class_list":["post-21708","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-server_vm"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts\/21708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/comments?post=21708"}],"version-history":[{"count":5,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts\/21708\/revisions"}],"predecessor-version":[{"id":21716,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts\/21708\/revisions\/21716"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/media\/21713"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/media?parent=21708"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/categories?post=21708"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/tags?post=21708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}