{"id":21961,"date":"2026-11-02T14:20:00","date_gmt":"2026-11-02T13:20:00","guid":{"rendered":"https:\/\/webhosting.de\/?p=21961"},"modified":"2026-10-30T12:49:30","modified_gmt":"2026-10-30T11:49:30","slug":"smartnics-en-la-aceleracion-de-la-red-de-alojamiento-web","status":"publish","type":"post","link":"https:\/\/webhosting.de\/es\/smartnics-im-hosting-netzwerkbeschleunigung\/","title":{"rendered":"SmartNIC en el alojamiento web: c\u00f3mo evaluar correctamente la aceleraci\u00f3n de red"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">Las SmartNIC no resultan rentables en el sector del alojamiento web por sus altas velocidades de puerto, sino cuando un puerto ocupado <strong style=\"font-weight:700;color:inherit\">Cuello de botella de la CPU en la ruta de datos de la red<\/strong> que se deriva de reglas recurrentes, superposiciones, conmutadores virtuales o cifrado. Lo decisivo es si la tarjeta, el firmware, los controladores y la plataforma reproducen realmente y en su totalidad en el hardware las correspondencias y acciones necesarias. De lo contrario, parte del procesamiento se queda en el host. Por lo tanto, antes de realizar una adquisici\u00f3n, la comprobaci\u00f3n de compatibilidad, la demostraci\u00f3n del flujo, la ruta de respaldo y el esfuerzo asociado al ciclo de vida deben tenerse en cuenta en la misma decisi\u00f3n.  <\/p>\n<nav class=\"wh-toc\" aria-label=\"Contenido de este art\u00edculo\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">Ir directamente a la secci\u00f3n<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#smartnic-grundlagen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">C\u00f3mo situar correctamente las SmartNIC en el \u00e1mbito del alojamiento web<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#datenpfad-und-offload\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">C\u00f3mo la descarga de hardware modifica la ruta de los datos<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#geeignete-hosting-szenarien\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Cu\u00e1ndo resulta conveniente utilizar SmartNICs en el alojamiento web<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#eignung-nach-einsatzfall\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Comparar los casos de uso desde el punto de vista t\u00e9cnico<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#integration-und-kompatibilitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Comprobar la compatibilidad antes del lanzamiento<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#alternativen-und-kapazitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Sopesar las ventajas de SmartNIC frente a la CPU y el software<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#betrieb-und-monitoring\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Hacer visible la descarga durante el funcionamiento<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#fehlerbilder-und-rueckfall\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Casos t\u00edpicos de fallo y v\u00edas de recuperaci\u00f3n<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#entscheidungsrahmen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Tomar decisiones realistas sobre la adquisici\u00f3n y la explotaci\u00f3n<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"smartnic-grundlagen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"smartnic-grundlagen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">C\u00f3mo situar correctamente las SmartNIC en el \u00e1mbito del alojamiento web<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">El t\u00e9rmino <strong style=\"font-weight:700;color:inherit\">SmartNIC<\/strong> No se trata de un nombre de producto estandarizado de forma uniforme. Por lo tanto, a la hora de planificar el alojamiento, lo decisivo no es la etiqueta, sino la funci\u00f3n demostrable en la ruta de datos: \u00bfqu\u00e9 paquetes, reglas y t\u00faneles puede procesar la tarjeta, qu\u00e9 tareas corresponden al servidor y qu\u00e9 software controla las funciones? Una alta velocidad de puerto no responde a estas preguntas.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una tarjeta de red cl\u00e1sica proporciona, sobre todo, la conexi\u00f3n Ethernet y admite funciones b\u00e1sicas de descarga habituales, como sumas de comprobaci\u00f3n o segmentaci\u00f3n. Una <strong style=\"font-weight:700;color:inherit\">SmartNIC<\/strong> ampl\u00eda este marco con funciones especializadas o programables de ruta de datos. Entre ellas pueden figurar reglas de flujo, funciones de conmutaci\u00f3n virtual, SR-IOV, procesamiento de t\u00faneles o tareas criptogr\u00e1ficas. Sin embargo, la disponibilidad de estas funciones depende conjuntamente del modelo, el firmware, los controladores y la integraci\u00f3n con la plataforma.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A <strong style=\"font-weight:700;color:inherit\">DPU<\/strong> suele tener una arquitectura m\u00e1s compleja: adem\u00e1s del ASIC de red, cuenta con recursos de c\u00e1lculo propios y puede gestionar una ruta de datos de infraestructura independiente. NVIDIA describe para BlueField un modo DPU, en el que el sistema ARM integrado controla los recursos de la NIC y la ruta de datos, as\u00ed como un modo NIC, en el que la tarjeta se comporta como un adaptador frente al host externo. De este modo, dependiendo del modo de funcionamiento, se crea tambi\u00e9n un \u00e1mbito de gesti\u00f3n y confianza propio.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Esta clasificaci\u00f3n tiene consecuencias pr\u00e1cticas para la adquisici\u00f3n y el funcionamiento. Una tarjeta con su propia l\u00f3gica de c\u00e1lculo no es autom\u00e1ticamente la mejor opci\u00f3n cuando solo se necesitan descargas b\u00e1sicas sencillas. Por el contrario, una ruta de infraestructura externalizada puede resultar \u00fatil para la segregaci\u00f3n de clientes o las funciones de seguridad, pero entonces requiere mantenimiento del firmware, conceptos de acceso, supervisi\u00f3n y procesos de recuperaci\u00f3n para componentes adicionales.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Ni siquiera un puerto de 100 GbE o m\u00e1s r\u00e1pido garantiza una aceleraci\u00f3n de las reglas del cortafuegos, las superposiciones o el cifrado. Los factores decisivos son el tama\u00f1o de los paquetes, el n\u00famero de flujos paralelos, el alcance de las reglas y si las acciones necesarias pueden realmente implementarse en el hardware. Solo cuando se demuestre que la CPU del servidor supone una limitaci\u00f3n en la ruta de datos de la red, la lista de funciones se convierte en una posible ganancia de capacidad.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"datenpfad-und-offload\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"datenpfad-und-offload\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">C\u00f3mo la descarga de hardware modifica la ruta de los datos<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Sin una descarga adicional, un paquete llega primero a la tarjeta de red f\u00edsica (NIC) y, a continuaci\u00f3n, es procesado por el host. Dependiendo de la arquitectura, pasa por la pila de red del kernel, el cortafuegos, el puente o el conmutador virtual, el enrutamiento y, si procede, la encapsulaci\u00f3n para una superposici\u00f3n. Solo entonces llega a una m\u00e1quina virtual, un contenedor u otro puerto f\u00edsico. Cada paso puede generar tiempo de CPU y colas.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Esta ruta cobra especial relevancia cuando hay muchos paquetes peque\u00f1os, numerosas conexiones de corta duraci\u00f3n o pol\u00edticas de clientes muy extensas. No es solo el volumen de datos transmitidos lo que sobrecarga el servidor, sino tambi\u00e9n el procesamiento repetido de paquetes y flujos individuales. Por eso, <strong style=\"font-weight:700;color:inherit\">aceleraci\u00f3n de red<\/strong> No se trata de una caracter\u00edstica general de un servidor, sino de una reducci\u00f3n espec\u00edfica de la carga en una ruta de datos concreta e identificada.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En <strong style=\"font-weight:700;color:inherit\">Descarga de hardware<\/strong> Los componentes de control pueden transferir las reglas de reenv\u00edo y filtrado permitidas a una ruta de datos de hardware. El modelo \u00abswitchdev\u00bb de Linux describe, a este respecto, el traslado de la ruta de datos de reenv\u00edo desde el n\u00facleo a un dispositivo de conmutaci\u00f3n. Las reglas que se aplican realmente dependen de la tarjeta concreta, de su controlador y de la integraci\u00f3n de red superior. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La documentaci\u00f3n de OVS en la rama de desarrollo 4.0.90 describe expresamente, en una secci\u00f3n dedicada a la descarga de hardware de Flow, que se trata de una funci\u00f3n experimental. Precisamente para esta configuraci\u00f3n de OVS con DPDK, distingue entre la descarga completa de coincidencias y acciones y la descarga parcial, en la que solo se descargan las coincidencias. Esta descripci\u00f3n no constituye una prueba de compatibilidad estable y de car\u00e1cter general para otras versiones de OVS, tarjetas de red o plataformas. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Por lo tanto, en la pr\u00e1ctica, cada declaraci\u00f3n de descarga debe especificar la ruta de datos concreta: versi\u00f3n del software utilizado, controladores, firmware, campos de coincidencia y acciones. El hecho de que un conmutador est\u00e9 activado no demuestra ni que los flujos relevantes se hayan descargado, ni que se sigan cumpliendo sin cambios los requisitos de seguridad y la sem\u00e1ntica de la red. En el caso del filtrado de VLAN, por ejemplo, switchdev exige que el hardware cumpla las reglas de VLAN de puente y descarte los ID de VLAN no autorizados.  La descarga es, por tanto, la aplicaci\u00f3n t\u00e9cnica de las reglas existentes, no una v\u00eda alternativa para eludirlas.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"geeignete-hosting-szenarien\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"geeignete-hosting-szenarien\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Cu\u00e1ndo resulta conveniente utilizar SmartNICs en el alojamiento web<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Las SmartNIC resultan especialmente adecuadas en plataformas de virtualizaci\u00f3n con numerosas m\u00e1quinas virtuales y decisiones de reenv\u00edo recurrentes. SR-IOV puede asignar una funci\u00f3n virtual a una m\u00e1quina virtual; en una arquitectura switchdev, las interfaces \u00abrepresentor\u00bb representan funciones f\u00edsicas o virtuales en el sistema operativo. De este modo, las reglas que rigen el tr\u00e1fico entre estos puertos pueden implementarse en el hardware.   No obstante, la utilidad depende de las funciones que requiera la m\u00e1quina virtual.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Redes superpuestas con capacidad para m\u00faltiples clientes y <strong style=\"font-weight:700;color:inherit\">Microsegmentaci\u00f3n<\/strong> son otro punto de partida. Si muchas redes de clientes aplican repetidamente asignaciones de VLAN o de superposici\u00f3n, reglas de control de acceso y decisiones similares sobre flujos, una ruta de datos de hardware adecuada puede aliviar la carga de las CPU de los hosts. El requisito previo sigue siendo que el n\u00famero de reglas, los campos de coincidencia y las acciones est\u00e9n disponibles en la tarjeta seleccionada, incluido el controlador, y que se mantenga \u00edntegramente la sem\u00e1ntica de las pol\u00edticas.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para OpenShift Container Platform 4.22, Red Hat documenta la descarga de hardware para nodos bare-metal con una SmartNIC compatible y un Network Operator SR-IOV activo. Solo se admite la comunicaci\u00f3n de pod a pod, as\u00ed como la comunicaci\u00f3n de pod a servicio ClusterIP con pods normales; las aplicaciones DPDK no son compatibles con esta funci\u00f3n. Adem\u00e1s, la ventaja se limita a los tramos de comunicaci\u00f3n en los que los nodos implicados utilizan SmartNIC compatibles. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de redes de host o de ubicaci\u00f3n cifradas, la descarga de IPsec puede encargarse de tareas parciales o de todo el proceso de encapsulaci\u00f3n, desencapsulaci\u00f3n, cifrado y protecci\u00f3n contra la repetici\u00f3n de paquetes. NVIDIA documenta diferentes tipos de descarga para este fin, entre ellos la descarga criptogr\u00e1fica y la descarga completa. Sin embargo, esto no implica una idoneidad universal: la compatibilidad y los l\u00edmites de rendimiento dependen del modelo, del firmware y del m\u00e9todo criptogr\u00e1fico.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un servidor de alojamiento web sencillo es, a prop\u00f3sito, un contraejemplo. Si env\u00eda principalmente un n\u00famero reducido de respuestas HTTP de gran tama\u00f1o y no muestra carga de CPU en la ruta de los paquetes, se puede utilizar un servidor m\u00e1s especializado <strong style=\"font-weight:700;color:inherit\">hardware de servidor<\/strong> solo suponen una carga operativa adicional. En primer lugar, hay que aclarar si el cuello de botella se debe a la aplicaci\u00f3n, la base de datos, el almacenamiento o la red. Las SmartNIC no son una alternativa viable para este diagn\u00f3stico.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"eignung-nach-einsatzfall\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"eignung-nach-einsatzfall\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Comparar los casos de uso desde el punto de vista t\u00e9cnico<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Lo que determina si una SmartNIC resulta \u00fatil no es la velocidad nominal del puerto, sino la ruta concreta de los datos. Su uso resulta especialmente recomendable cuando hay muchas reglas recurrentes, un elevado n\u00famero de flujos o funciones de superposici\u00f3n y de seguridad que consumen constantemente tiempo de la CPU del host. La ventaja sigue siendo <strong style=\"font-weight:700;color:inherit\">dependiente de la trayectoria<\/strong>: Un tramo acelerado solo beneficia a las conexiones que realmente se ejecutan mediante hardware compatible y reglas admitidas. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Idoneidad de la descarga de SmartNIC seg\u00fan el caso de uso de alojamiento\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Idoneidad de la descarga de SmartNIC seg\u00fan el caso de uso de alojamiento<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Caso pr\u00e1ctico<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Posible ventaja<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Requisitos t\u00e9cnicos<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Restricci\u00f3n t\u00edpica<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Punto de verificaci\u00f3n antes del lanzamiento<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Alojamiento de m\u00e1quinas virtuales con SR-IOV<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">El reenv\u00edo entre funciones virtuales puede realizarse a trav\u00e9s del eSwitch.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Tarjeta adecuada, controladores e integraci\u00f3n con Representor o eSwitch.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Las funciones de red de las m\u00e1quinas virtuales y la observabilidad pueden variar.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Probar las funciones de las m\u00e1quinas virtuales compatibles, las reglas de seguridad y la migraci\u00f3n.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">OpenShift 4.22 con OVN-Kubernetes<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Las rutas de servicio de Pod y ClusterIP documentadas pueden aprovechar la descarga de carga en el hardware.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Nodos \u00abbare metal\u00bb compatibles, operador de red SR-IOV y configuraci\u00f3n de pod adecuada.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Solo se admiten determinados tipos de comunicaci\u00f3n; las aplicaciones DPDK no son compatibles con esto.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Comparar las rutas de pods, servicios y nodos compatibles con la versi\u00f3n de la plataforma.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Redes superpuestas<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">El procesamiento en t\u00fanel y unas reglas de reenv\u00edo sencillas pueden reducir la carga de la CPU.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Asistencia para los t\u00faneles, las combinaciones y las acciones necesarias.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Las acciones no compatibles provocan una descarga parcial o nula.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Comprobar el formato del t\u00fanel, el alcance de las reglas y las reca\u00eddas en el software.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">IPsec<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">La encapsulaci\u00f3n, la desencapsulaci\u00f3n y las tareas criptogr\u00e1ficas pueden externalizarse en funci\u00f3n del modelo.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Modelo de tarjeta compatible, firmware y variante de descarga de IPsec compatible.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Las funciones y limitaciones dependen de la generaci\u00f3n y de la configuraci\u00f3n.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Comprueba si el modelo de destino cuenta con capacidad documentada de \u00abcrypto\u00bb o de \u00abfull-offload\u00bb.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Ruta de datos de infraestructura programable<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Se pueden implementar procesos de flujo especializados para las funciones adecuadas.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Debe garantizarse de forma concreta la integraci\u00f3n necesaria en cuanto a estado, control y plataforma.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">La descripci\u00f3n de las funciones proporcionada por un fabricante no es v\u00e1lida para otras SmartNIC.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Comparar de forma concreta la sem\u00e1ntica de coincidencia, acci\u00f3n y estado necesaria.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Servidor de alojamiento web sencillo<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Como mucho, una reducci\u00f3n de la carga mediante las descargas habituales de la NIC.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Se ha detectado que la ruta de datos de red es un cuello de botella.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">La carga de las aplicaciones, las bases de datos o el almacenamiento no se ve afectada.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Recopilar informaci\u00f3n sobre la CPU y la red antes de realizar una inversi\u00f3n en hardware.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de las plataformas de m\u00e1quinas virtuales, <strong style=\"font-weight:700;color:inherit\">SR-IOV<\/strong> Un enfoque t\u00edpico: las funciones virtuales se asignan a una m\u00e1quina virtual, mientras que las interfaces \u00abRepresentor\u00bb del sistema operativo mapean los puertos de dichas funciones. De este modo, las reglas de reenv\u00edo entre puertos virtuales y f\u00edsicos pueden implementarse en hardware dentro de una arquitectura orientada a \u00abswitchdev\u00bb. Sin embargo, esto no sustituye a la comprobaci\u00f3n de si se mantienen la separaci\u00f3n de clientes deseada y el modelo operativo. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Kubernetes es lo contrario a una promesa general de aceleraci\u00f3n. Para la integraci\u00f3n documentada con OpenShift 4.22 se aplican determinadas rutas de tr\u00e1fico compatibles, nodos SmartNIC compatibles y requisitos de carga de trabajo. Si un nodo con capacidad de descarga comunica con un nodo normal, este \u00faltimo procesa su parte en el n\u00facleo, lo que limita as\u00ed la ruta total. Por lo tanto, una implementaci\u00f3n deber\u00eda tener en cuenta, en primer lugar, un conjunto de nodos delimitado y v\u00edas de comunicaci\u00f3n reales. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de redes de host o de ubicaci\u00f3n cifradas, estos t\u00e9rminos deben utilizarse con especial precisi\u00f3n. Las variantes documentadas de IPsec van, seg\u00fan la plataforma, desde la descarga de cifrado (Crypto-Offload) hasta la descarga completa (Full Offload) para la encapsulaci\u00f3n, la desencapsulaci\u00f3n, el cifrado y la protecci\u00f3n contra la repetici\u00f3n de paquetes. De ello no se deriva ninguna garant\u00eda general de rendimiento: el modelo, el firmware, los algoritmos utilizados y las limitaciones propias del producto determinan qu\u00e9 parte del procesamiento se externaliza realmente.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"integration-und-kompatibilitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"integration-und-kompatibilitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Comprobar la compatibilidad antes del lanzamiento<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La adquisici\u00f3n comienza con un an\u00e1lisis inicial sin modificaciones, no con la activaci\u00f3n de opciones de descarga. Registra el modelo exacto de la tarjeta, incluyendo el ID PCI, la versi\u00f3n del firmware, los controladores y el n\u00facleo. Adem\u00e1s, es necesario conocer el modo eSwitch, as\u00ed como la versi\u00f3n y la configuraci\u00f3n de Open vSwitch, OVN, el hipervisor o la plataforma Kubernetes, ya que la capacidad de la tarjeta por s\u00ed sola no garantiza una integraci\u00f3n completa del software.  <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-1024x683.webp\" class=\"wp-image-21965\" alt=\"Una administradora comprueba una tarjeta de red PCIe antes de instalarla en un servidor.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Imagen ilustrativa generada por IA para la comprobaci\u00f3n del hardware y la plataforma antes de la implantaci\u00f3n de una descarga.<\/figcaption><\/figure><div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Comprobaci\u00f3n r\u00e1pida de compatibilidad antes de la implantaci\u00f3n de la descarga\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Comprobaci\u00f3n r\u00e1pida de compatibilidad antes de la implantaci\u00f3n de la descarga<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Nivel de prueba<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Informaci\u00f3n que debe registrarse<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Por qu\u00e9 es relevante<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Hardware<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Modelo de tarjeta, ID de PCI y configuraci\u00f3n de puertos<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Determina las funciones ASIC y las funciones virtuales disponibles.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Firmware y controladores<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Versiones exactas y kernel compatible<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">La tarjeta y el host deben contar con implementaciones compatibles entre s\u00ed.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Modo de ruta de datos<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Configuraci\u00f3n de eSwitch y switchdev<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Determina si las reglas pueden transferirse a una ruta de datos de un conmutador de hardware.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Conmutaci\u00f3n virtual<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Versi\u00f3n de OVS, OVN o hipervisor<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Determina qu\u00e9 funciones puede solicitar el software para esta combinaci\u00f3n.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Sem\u00e1ntica de las reglas<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Protocolos, t\u00faneles y acciones necesarios<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Solo las reglas representables pueden ejecutarse \u00edntegramente en hardware.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Detecci\u00f3n y reincidencia<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Estado del flujo, contador y sistema de respaldo del software<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Permite detectar la descarga parcial y las reglas no compatibles durante el funcionamiento.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La sem\u00e1ntica de las reglas necesarias deber\u00eda estar disponible de antemano como descripci\u00f3n de la ruta de datos: por ejemplo, asignaci\u00f3n de VLAN, IPv4 o IPv6, TCP o UDP, tipo de t\u00fanel, modificaci\u00f3n de la cabecera, reenv\u00edo o descarte. La documentaci\u00f3n experimental de OVS 4.0.90 muestra, en relaci\u00f3n con su configuraci\u00f3n DPDK, que la ausencia de acciones de hardware puede dar lugar a una descarga parcial. De ello se deduce que, para cualquier otra versi\u00f3n o plataforma, solo se trata de una tarea de comprobaci\u00f3n, sin garant\u00eda alguna sobre su alcance funcional. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Las matrices de plataforma son <strong style=\"font-weight:700;color:inherit\">Certificados de compatibilidad espec\u00edficos para cada versi\u00f3n<\/strong>, no se hacen afirmaciones generales sobre una familia de tarjetas de red. OpenShift 4.22 especifica tarjetas de red concretas para su integraci\u00f3n de descarga de hardware, entre las que se incluye BlueField-2 en modo ConnectX-6. De ello no se puede deducir ni la compatibilidad con otro firmware, ni con otro modo de DPU, ni con una distribuci\u00f3n diferente. Por lo tanto, documenta por separado cada combinaci\u00f3n de hardware, firmware, controlador y versi\u00f3n de la plataforma. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para Linux-switchdev tambi\u00e9n es fundamental que el hardware respete la sem\u00e1ntica de la red de software. En el filtrado de VLAN, por ejemplo, un conmutador que realiza la descarga debe respetar las reglas de VLAN del puente y descartar los ID de VLAN no permitidos. Este requisito pone de manifiesto por qu\u00e9 es necesario comprobar conjuntamente las listas de funciones y la pol\u00edtica de seguridad: la aceleraci\u00f3n no debe generar una segmentaci\u00f3n de red diferente. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"alternativen-und-kapazitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"alternativen-und-kapazitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Sopesar las ventajas de SmartNIC frente a la CPU y el software<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una SmartNIC es solo una de las varias opciones cuando el procesamiento de red es limitado. En primer lugar, conviene comprobar si una mayor capacidad de la CPU, un n\u00famero adecuado de colas, el RSS, la distribuci\u00f3n de IRQ o el ajuste del n\u00facleo ya resuelven el cuello de botella. Para comprender mejor el funcionamiento de las SoftIRQ, las colas y la distribuci\u00f3n de interrupciones, consulta el art\u00edculo sobre <a href=\"https:\/\/webhosting.de\/es\/softirq-cpu-hosting-red-rendimiento-optimizacion-datacenter\/\">Rendimiento de la CPU y del tr\u00e1fico de red en el alojamiento web<\/a> Conceptos b\u00e1sicos adicionales. Sin pruebas que demuestren la existencia de un cuello de botella en la red, el hardware especial adicional no deja de ser una suposici\u00f3n.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">DPDK y AF_XDP pueden acortar las rutas de software en las CPU del host, pero cada uno requiere una planificaci\u00f3n espec\u00edfica de la arquitectura y la CPU. La afirmaci\u00f3n sobre el sondeo continuo no puede aplicarse de forma generalizada a ambos enfoques: En la documentaci\u00f3n de OVS-DPDK para la configuraci\u00f3n descrita, un hilo sondea continuamente los dispositivos DPDK y, al hacerlo, ocupa por completo un n\u00facleo de la CPU. Por lo tanto, la asignaci\u00f3n NUMA, el aislamiento de n\u00facleos y las versiones concretas de OVS y DPDK siguen formando parte del dise\u00f1o. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una tarjeta de red cl\u00e1sica para servidor tambi\u00e9n puede proporcionar una descarga de carga suficiente para sumas de comprobaci\u00f3n, segmentaci\u00f3n o caracter\u00edsticas espec\u00edficas de los t\u00faneles. Esta opci\u00f3n resulta adecuada cuando no se requieren reglas de conmutaci\u00f3n virtual complejas, segregaci\u00f3n de clientes ni rutas de datos de seguridad en el hardware. Las SmartNIC cobran especial sentido cuando las funciones requeridas van m\u00e1s all\u00e1 de esas caracter\u00edsticas b\u00e1sicas y son recurrentes a largo plazo.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">El concepto de capacidad es sencillo, pero importante: si los n\u00facleos de la CPU de un host est\u00e1n ocupados procesando paquetes y se puede descargar por completo una parte representativa de esos paquetes, es posible que se genere margen de CPU. Sin embargo, este margen solo se considera capacidad utilizable si ni la aplicaci\u00f3n, ni la memoria, ni el almacenamiento, ni un plan de contingencia de software constituyen el siguiente cuello de botella. No se trata de una derivaci\u00f3n directa de la velocidad del enlace ni del precio de la tarjeta.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Por lo tanto, compara las alternativas bas\u00e1ndote en el mismo perfil de carga: tama\u00f1o de los paquetes, velocidad de conexi\u00f3n, n\u00famero de reglas, t\u00faneles, cifrado y carga m\u00e1xima prevista. Para ello, analiza por separado la participaci\u00f3n de la CPU en la ruta de datos y en el trabajo de la aplicaci\u00f3n, y comprueba qu\u00e9 flujos se ejecutan realmente en el hardware. Un <strong style=\"font-weight:700;color:inherit\">Cuello de botella de la CPU<\/strong> El uso de un cortafuegos, una red superpuesta o un reenv\u00edo virtual constituye un motivo v\u00e1lido para la evaluaci\u00f3n; una carga elevada general del sistema no lo es.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"betrieb-und-monitoring\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"betrieb-und-monitoring\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Hacer visible la descarga durante el funcionamiento<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Tras la puesta en marcha, no basta con comprobar que la opci\u00f3n de descarga est\u00e9 activa. Una prueba de funcionamiento fiable vincula el <strong style=\"font-weight:700;color:inherit\">Estado del flujo<\/strong> con los contadores de la tarjeta, las tasas de p\u00e9rdida y de error, la utilizaci\u00f3n de la CPU, as\u00ed como un perfil de carga similar al tr\u00e1fico posterior. Solo en conjunto, estos datos revelan si los flujos relevantes se procesan realmente en el hardware o si el host sigue asumiendo la mayor parte de la ruta de datos.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para realizar la comparaci\u00f3n, los operadores deben tener en cuenta los mismos tama\u00f1os de paquetes, protocolos, n\u00famero de conexiones y pol\u00edticas, tanto antes como despu\u00e9s de un cambio. El rendimiento puro en gigabits puede ocultar f\u00e1cilmente un cuello de botella en el caso de paquetes peque\u00f1os o de muchos flujos paralelos. Son igualmente importantes la latencia, el tiempo de CPU por host implicado, la carga de Softirq, las p\u00e9rdidas en la cola y la distribuci\u00f3n del tr\u00e1fico entre nodos y puertos.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-1024x683.webp\" class=\"wp-image-21966\" alt=\"Puertos de red de un servidor de rack con cables de fibra \u00f3ptica conectados durante una inspecci\u00f3n t\u00e9cnica.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Imagen ilustrativa generada por IA para la observaci\u00f3n de rutas f\u00edsicas de red y sus opciones de ruta alternativa.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Los siguientes comandos no modifican ninguna configuraci\u00f3n. La primera consulta tiene en cuenta tanto los dispositivos PCI que aparecen como \u00abEthernet controller\u00bb como los que aparecen como \u00abNetwork controller\u00bb. <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">ethtool -k<\/code> Muestra las funciones de descarga disponibles o activadas en Netdev, pero no confirma de forma completa ni la descarga de eSwitch, ni la de SmartNIC, ni la de flujos. El resto de los resultados son datos de inventario y configuraci\u00f3n, y no constituyen una prueba de que una regla concreta se haya descargado por completo.<\/p>\n<div class=\"wh-code-window\" data-wh-code style=\"margin:28px 0 34px;border:1px solid #2c4656;border-radius:12px;overflow:hidden;background:#132a3b;box-shadow:0 9px 25px -13px rgba(15,35,55,.2)\"><div class=\"wh-code-toolbar\" style=\"display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:10px;padding:11px 16px;background:#223e50;color:#edf5fa;font-size:13px;line-height:1.5;font-weight:600\"><span>Terminal<\/span><button type=\"button\" class=\"wh-code-copy\" data-wh-copy hidden style=\"padding:6px 11px;border:1px solid #7893a1;border-radius:6px;background:transparent;color:#fff;font-size:12px;line-height:1.5;font-weight:600;cursor:pointer\">Copiar c\u00f3digo<\/button><span class=\"wh-copy-status\" aria-live=\"polite\"><\/span><span data-wh-copy-success hidden>Copiado<\/span><span data-wh-copy-fallback hidden>C\u00f3digo resaltado: por favor, c\u00f3pialo<\/span><\/div><pre class=\"wh-code\" data-no-translation translate=\"no\" style=\"display:block;margin:0;padding:20px;max-width:100%;overflow-x:auto;color:#edf5fa;background:#132a3b;font:14px\/1.75 ui-monospace,SFMono-Regular,Menlo,Consolas,monospace;white-space:pre;direction:ltr;text-align:left\"><code class=\"language-bash\" style=\"font:inherit;color:inherit;background:transparent;padding:0;border:0;white-space:inherit\">lspci -nn | grep -Ei &#039;Ethernet controller|Network controller&#039;\nethtool -k &lt;interface&gt;\nethtool -i &lt;interface&gt;\ndevlink dev show\novs-vsctl get Open_vSwitch . other_config<\/code><\/pre><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de Open vSwitch, hay que distinguir especialmente entre la aceleraci\u00f3n por hardware configurada y el resultado observado. La documentaci\u00f3n de desarrollo de OVS 4.0.90 califica su descarga de flujo en hardware como experimental y describe la descarga total o parcial \u00fanicamente para esta configuraci\u00f3n de OVS con DPDK. Por lo tanto, para el funcionamiento en producci\u00f3n, la informaci\u00f3n de flujos y los contadores de hardware deben evaluarse junto con los contadores de software del host. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Adem\u00e1s, la supervisi\u00f3n requiere una referencia temporal. Una prueba breve puede confirmar ciertas reglas, mientras que un perfil cercano a la producci\u00f3n puede desencadenar posteriormente problemas de capacidad de las tablas, rutas de registro poco frecuentes o reconfiguraciones. Por lo tanto, es recomendable registrar los valores normales y las anomal\u00edas por modelo de tarjeta, firmware, controlador y versi\u00f3n de la plataforma. De este modo, tras las actualizaciones, se puede comprobar si el <strong style=\"font-weight:700;color:inherit\">Ruta de datos<\/strong> o simplemente ha variado la carga observada.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En la integraci\u00f3n con OpenShift 4.22, la vista debe abarcar adem\u00e1s toda la ruta de comunicaci\u00f3n. La compatibilidad documentada con la descarga de hardware solo se aplica a determinadas cargas de trabajo y tipos de comunicaci\u00f3n. Si un nodo compatible se comunica con un nodo que no dispone de una SmartNIC adecuada, este \u00faltimo procesa su tramo en el n\u00facleo; en ese caso, los puntos de medici\u00f3n en un solo host pueden ofrecer una visi\u00f3n incompleta de la ruta de extremo a extremo. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"fehlerbilder-und-rueckfall\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"fehlerbilder-und-rueckfall\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Casos t\u00edpicos de fallo y v\u00edas de recuperaci\u00f3n<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">El error m\u00e1s frecuente es <strong style=\"font-weight:700;color:inherit\">descarga incompleta<\/strong>. Un flujo puede identificarse en el hardware a partir de caracter\u00edsticas sencillas; sin embargo, en el caso de una acci\u00f3n no compatible, debe volver, total o parcialmente, a la ruta de software. La documentaci\u00f3n experimental de OVS 4.0.90 describe esta descarga parcial para su configuraci\u00f3n DPDK. No se trata de una afirmaci\u00f3n generalizable a todas las instalaciones de OVS, pero pone de manifiesto el punto de verificaci\u00f3n necesario en cada integraci\u00f3n concreta. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">El diagn\u00f3stico comienza a lo largo de la ruta real: puerto de entrada, funci\u00f3n virtual o representador, regla de conmutaci\u00f3n, procesamiento del t\u00fanel o de la pol\u00edtica y carga de trabajo de destino. Si los contadores situados antes y despu\u00e9s de una etapa no coinciden de forma plausible, esto constituye un motivo para comprobar las coincidencias, las acciones y el mecanismo de reserva. Una funci\u00f3n activada no sustituye a esta asignaci\u00f3n, ya que la capacidad de la tarjeta no abarca todas las combinaciones de reglas deseadas.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Los cl\u00fasteres heterog\u00e9neos dificultan la comparaci\u00f3n. En OpenShift 4.22, la descarga de hardware solo se produce si los pods y servicios implicados est\u00e1n asignados a nodos con una SmartNIC compatible. Si una ruta de este tipo se encuentra con un nodo normal, su procesamiento se lleva a cabo en el n\u00facleo, lo que limita la comunicaci\u00f3n total. Por lo tanto, un \u00fanico nodo acelerado no ocupa una ruta de cl\u00faster totalmente acelerada. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una configuraci\u00f3n inadecuada de los pods o de la red tambi\u00e9n puede impedir que se produzca el efecto esperado. Red Hat se\u00f1ala expresamente, en relaci\u00f3n con la funci\u00f3n de OpenShift 4.22, que la descarga de hardware activada sin unos pods configurados adecuadamente puede reducir el rendimiento de los pods. Por lo tanto, los administradores no deber\u00edan intentar solucionar una anomal\u00eda activando m\u00e1s opciones, sino que deber\u00edan comprobar primero la conexi\u00f3n de la carga de trabajo, el modo de red y los flujos realmente alcanzados. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La capacidad de regulaci\u00f3n y las desviaciones del firmware pertenecen a la misma clase de errores: en el caso de muchos clientes, conexiones de corta duraci\u00f3n o pol\u00edticas din\u00e1micas, el volumen de flujo relevante puede crecer de forma diferente a la esperada. Adem\u00e1s, un controlador vinculado a una versi\u00f3n concreta o un firmware diferente pueden ofrecer funciones distintas a las de la combinaci\u00f3n de plataformas prevista. Por ello, los datos de inventario y los contadores deben archivarse siempre junto con el conjunto concreto de reglas.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A <strong style=\"font-weight:700;color:inherit\">ruta de retroceso controlada<\/strong> permite diagnosticar el funcionamiento. Implica que el procesamiento por software se mantiene como alternativa prevista y que los cambios se implementan de forma gradual, con ventanas de comparaci\u00f3n y criterios de interrupci\u00f3n claros. El \u00abfallback\u00bb de software no es, por s\u00ed mismo, un defecto, sino que puede constituir el tratamiento previsto para aquellas acciones que la ruta de hardware elegida no admite por completo.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"entscheidungsrahmen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"entscheidungsrahmen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Tomar decisiones realistas sobre la adquisici\u00f3n y la explotaci\u00f3n<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una decisi\u00f3n de adquisici\u00f3n debe partir de la carga de trabajo, no de la velocidad del puerto ni de la denominaci\u00f3n del producto. El uso de hardware especializado resulta plausible cuando se demuestra que el procesamiento recurrente de paquetes consume tiempo de CPU: por ejemplo, en el caso de numerosas redes virtuales, conjuntos de pol\u00edticas estables, tr\u00e1fico de superposici\u00f3n o una ruta de cifrado definida. A falta de esta evidencia, el ajuste de la CPU y de las colas, o una tarjeta de red cl\u00e1sica con descargas b\u00e1sicas adecuadas, pueden ser la soluci\u00f3n m\u00e1s sencilla.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A continuaci\u00f3n, hay que... <strong style=\"font-weight:700;color:inherit\">Certificado de compatibilidad<\/strong> que funcionen para la combinaci\u00f3n concreta: modelo de tarjeta y modo de funcionamiento, firmware, controladores, n\u00facleo, conmutador virtual o CNI, as\u00ed como las funciones de coincidencia y acci\u00f3n necesarias. Los aceleradores de infraestructura programables pueden, por ejemplo, proporcionar descarga de flujos para funciones relacionadas con el estado o la sesi\u00f3n; sin embargo, esto no implica que todas las SmartNIC o todas las plataformas ofrezcan la misma funci\u00f3n. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La reducci\u00f3n prevista de la carga de la CPU solo estar\u00e1 disponible como capacidad cuando el procesamiento de paquetes haya sido el cuello de botella y los n\u00facleos liberados puedan utilizarse de forma adecuada. Si, por ejemplo, se asignan a bases de datos, web workers o reservas, se trata de una decisi\u00f3n arquitect\u00f3nica, no de una mejora autom\u00e1tica del rendimiento. Por lo tanto, el resto del equipamiento del servidor sigue siendo fundamental; la CPU, la memoria RAM y el almacenamiento deben adaptarse a la aplicaci\u00f3n tanto como la red. El art\u00edculo sobre <a href=\"https:\/\/webhosting.de\/es\/alto-rendimiento-webhosting-hardware-cpu-nvme-memoria-rendimiento-turbo-servidor\/\">Hardware de servidor relevante para el rendimiento en el alojamiento web<\/a>.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En el caso de IPsec, la comprobaci\u00f3n es especialmente concreta: las variantes de descarga documentadas van desde la descarga criptogr\u00e1fica hasta la externalizaci\u00f3n completa de la encapsulaci\u00f3n, la desencapsulaci\u00f3n, el cifrado y la protecci\u00f3n contra la repetici\u00f3n. La variante que se pueda utilizar depende del modelo, la generaci\u00f3n, el firmware y la configuraci\u00f3n criptogr\u00e1fica. Adem\u00e1s, las indicaciones espec\u00edficas del producto pueden incluir limitaciones para determinadas generaciones o anchos de banda; estas deben tenerse en cuenta en la comprobaci\u00f3n de autorizaci\u00f3n antes de la implantaci\u00f3n.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una DPU ampl\u00eda la decisi\u00f3n con un \u00e1mbito propio de gesti\u00f3n y confianza. En el modo BlueField-DPU, el sistema Arm integrado controla los recursos de la NIC y la ruta de datos, en lugar de que la tarjeta funcione \u00fanicamente como adaptador del host. Esto permite separar las tareas de infraestructura del host, pero requiere un dise\u00f1o s\u00f3lido en cuanto a derechos de acceso, im\u00e1genes, actualizaciones, supervisi\u00f3n y recuperaci\u00f3n. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Por lo tanto, desde el punto de vista econ\u00f3mico, no solo cuenta el precio de la tarjeta. Hay que tener en cuenta tambi\u00e9n la capacidad de la CPU del host que se ahorra o se evita utilizar, la vida \u00fatil prevista de la plataforma, as\u00ed como los costes adicionales derivados de la certificaci\u00f3n, las piezas de recambio, el mantenimiento del firmware y la recuperaci\u00f3n ante incidentes. Una SmartNIC resulta \u00fatil cuando este c\u00e1lculo se basa en una ruta de datos reproducible y en un ciclo de vida controlable a largo plazo, y no porque el hardware especializado parezca, en principio, m\u00e1s r\u00e1pido.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Fuentes y estado actual de los conocimientos<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Estado de la investigaci\u00f3n: <time datetime=\"2026-10-24\">2026-10-24<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Fecha de la investigaci\u00f3n: 24 de octubre de 2026. Las informaciones sobre funciones y compatibilidad dependen de la versi\u00f3n, el modelo y la plataforma; antes del lanzamiento, se aplicar\u00e1n las matrices correspondientes del fabricante y de la plataforma.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.kernel.org\/networking\/switchdev.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.openvswitch.org\/en\/latest\/howto\/dpdk\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/doca\/archive\/2-5-3\/nvidia%2Bbluefield%2Bdpu%2Bmodes%2Bof%2Boperation\/index.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.kernel.org\/6.16\/networking\/representors.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.redhat.com\/en\/documentation\/openshift_container_platform\/4.22\/html\/hardware_networks\/configuring-hardware-offloading<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/doca\/archive\/doca-v2.2.1\/ipsec-programming-guide\/index.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.amd.com\/r\/en-US\/ug1670-amd-pensando-ssdk-flow-offload-user-guide\/Introduction<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/networking\/display\/MLNXOFEDv23103220lts\/IPsec%2BFull%2BOffload<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.openvswitch.org\/en\/stable\/howto\/dpdk\/<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>Los SmartNIC pueden descargar de las CPU de los hosts las tareas de red recurrentes. Que esto resulte rentable depende de la ruta real de los datos, las reglas compatibles, la integraci\u00f3n en la plataforma y el esfuerzo operativo adicional.<\/p>","protected":false},"author":1,"featured_media":21964,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[922],"tags":[],"class_list":["post-21961","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technologie"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts\/21961","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/comments?post=21961"}],"version-history":[{"count":3,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts\/21961\/revisions"}],"predecessor-version":[{"id":21967,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/posts\/21961\/revisions\/21967"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/media\/21964"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/media?parent=21961"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/categories?post=21961"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/es\/wp-json\/wp\/v2\/tags?post=21961"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}