{"id":21708,"date":"2026-09-25T10:03:34","date_gmt":"2026-09-25T08:03:34","guid":{"rendered":"https:\/\/webhosting.de\/?p=21708"},"modified":"2026-09-25T10:03:37","modified_gmt":"2026-09-25T08:03:37","slug":"web-hosting-con-amd-epyc-o-intel-xeon","status":"publish","type":"post","link":"https:\/\/webhosting.de\/it\/amd-epyc-oder-intel-xeon-webhosting\/","title":{"rendered":"AMD EPYC o Intel Xeon: scegliere la piattaforma giusta per il web hosting"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">Per quanto riguarda il web hosting, non esiste un vincitore assoluto tra AMD EPYC e Intel Xeon. <strong style=\"font-weight:700;color:inherit\">La piattaforma adeguata si adatta al profilo di carico<\/strong>: Nel shared hosting contano la densit\u00e0 dei core e i limiti, mentre nelle applicazioni dinamiche \u00e8 importante la prestazione per worker attivo; i nodi VPS e di database, invece, richiedono soprattutto RAM, layout NUMA e topologia I\/O. Confronta quindi modelli specifici di EPYC 9005 e Xeon 6, insieme alla piattaforma server, sulla base di misurazioni riproducibili anzich\u00e9 in base al numero di core, alla frequenza di clock o a singoli benchmark.   <\/p>\n<nav class=\"wh-toc\" aria-label=\"Contenuto di questo articolo\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">Vai direttamente alla sezione<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#hosting-profile\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Profili di hosting prima del confronto delle prestazioni della CPU<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#plattformen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Inserire EPYC 9005 e Xeon 6 come termine di paragone<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#ressourcen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">I semi sono solo uno dei fattori<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#workload-matrix\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Sincronizzare i carichi di lavoro con la piattaforma<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#benchmark-protokoll\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Pianificare correttamente i benchmark della CPU per l'hosting<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#konfigurationscheck\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Verifica della configurazione e della topologia<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#virtualisierung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Gestire la virtualizzazione in modo sicuro e pianificabile<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#fehlerquellen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Fonti di errore durante il confronto e il funzionamento<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#entscheidung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Decidere gli acquisti in base a requisiti misurabili<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"hosting-profile\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"hosting-profile\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Profili di hosting prima del confronto delle prestazioni della CPU<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Il web hosting non rappresenta un carico di lavoro uniforme per la CPU. Una piattaforma che ospita migliaia di piccoli account segue regole diverse rispetto a un nodo per macchine virtuali o a un server di database. Prima di confrontare AMD EPYC e Intel Xeon, \u00e8 quindi necessario definire il profilo delle richieste, il numero di client attivi contemporaneamente, il fabbisogno di RAM, l\u2019I\/O di storage e i tempi di risposta accettabili. Solo questa combinazione rende significativi i dati tecnici di una CPU ai fini dell\u2019acquisto.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><strong style=\"font-weight:700;color:inherit\">hosting condiviso<\/strong> elabora numerose attivit\u00e0 PHP, CMS e di posta elettronica indipendenti l'una dall'altra, spesso caratterizzate da brevi picchi di carico. Un'elevata densit\u00e0 di core pu\u00f2 essere d'aiuto, ma \u00e8 altrettanto importante stabilire limiti efficaci per il tempo di CPU, i processi, la memoria e l'I\/O. Senza tali limiti, un singolo account pu\u00f2 occupare risorse limitate e peggiorare i tempi di risposta degli altri clienti. In questo caso, una separazione pianificabile dei clienti conta spesso pi\u00f9 di un valore di picco in un test multicore sintetico.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Nel caso dei CMS e degli shop gestiti, i requisiti sono pi\u00f9 eterogenei. Richieste PHP dinamiche, cache degli oggetti, interrogazioni del database, cron job e accessi amministrativi si verificano talvolta contemporaneamente. Per alcune applicazioni particolarmente esigenti \u00e8 possibile <strong style=\"font-weight:700;color:inherit\">Prestazioni per core<\/strong> pu\u00f2 essere pi\u00f9 importante del numero massimo di core; quando si hanno molti worker PHP-FPM indipendenti in modo permanente, invece, la parallelizzazione assume maggiore importanza. Ci\u00f2 che rimane determinante \u00e8 che il server web, i processi PHP e il database siano dimensionati in modo adeguato.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un negozio WooCommerce illustra chiaramente questa distinzione: un server web dotato di cache \u00e8 in grado di fornire in modo molto efficiente le immagini statiche dei prodotti. Il carrello, il checkout e le disponibilit\u00e0 di magazzino, invece, generano esecuzioni PHP personalizzate e accessi al database. Un numero maggiore di core della CPU non elimina i tempi di attesa se le query non trovano gli indici, il buffer pool \u00e8 troppo piccolo o la latenza NVMe aumenta sotto carico. Pertanto, la latenza delle richieste, i tempi di risposta del database e i tempi di attesa I\/O dovrebbero essere misurati separatamente.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I nodi VPS e cloud, oltre alla potenza di calcolo, necessitano soprattutto di RAM sufficiente, larghezza di banda di memoria, rete e una distribuzione delle risorse trasparente. Il CPU-pinning, la memoria riservata, l\u2019assegnazione NUMA e lo Storage-QoS influenzano l\u2019esperienza degli utenti in misura maggiore rispetto al logo del produttore. I sistemi legati a database, Redis e storage valutano inoltre il working set, la dimensione della cache, il carico di scrittura e il collegamento diretto agli SSD NVMe. In questo caso \u00e8 importante un equilibrio <strong style=\"font-weight:700;color:inherit\">Topologia della piattaforma<\/strong> spesso pi\u00f9 determinante rispetto al semplice valore di throughput di un server web.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"plattformen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"plattformen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Inserire EPYC 9005 e Xeon 6 come termine di paragone<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Questo articolo mette a confronto, in modo mirato, AMD EPYC 9005 e Intel Xeon 6 come generazioni di piattaforme chiaramente distinte. Il confronto \u00e8 finalizzato all\u2019acquisto, all\u2019espansione o alla valutazione di sistemi basati su queste due famiglie di prodotti. Da esso non \u00e8 possibile trarre conclusioni relative ad altre generazioni o linee di prodotti, poich\u00e9 la struttura dei core, la piattaforma di memoria, le dotazioni I\/O e le funzioni disponibili possono variare.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Una funzione del processore documentata deve inoltre corrispondere effettivamente a una <strong style=\"font-weight:700;color:inherit\">sistema server disponibile<\/strong> da distinguere. Scheda madre, firmware, configurazione DIMM, raffreddamento, alimentatori e approvazioni OEM determinano quali configurazioni sono effettivamente utilizzabili. Verifica quindi, per ogni SKU specifica, quali modelli di server sono disponibili e convalidati per la configurazione prevista. Ci\u00f2 vale in particolare per elevate capacit\u00e0 di RAM, numerose unit\u00e0 NVMe e funzioni di virtualizzazione speciali.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Le generazioni precedenti di EPYC 700x e i modelli precedenti di Xeon Scalable non devono essere confusi con EPYC 9005 o Xeon 6. Allo stesso modo, non si dovrebbero applicare a queste famiglie i dati relativi ad altre linee di prodotti. La struttura dei core, le dotazioni I\/O, la piattaforma di memoria e le funzionalit\u00e0 disponibili possono variare da una generazione all\u2019altra. Per un confronto tra le opzioni di acquisto \u00e8 quindi sempre necessario disporre della denominazione completa del modello, del numero di socket e della scheda madre del server utilizzata.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La serie EPYC 9005 comprende, a seconda del modello, processori con <strong style=\"font-weight:700;color:inherit\">Zen 5<\/strong>\u2013 o core Zen-5c. Queste denominazioni non indicano una classifica generale per l\u2019hosting. Sono invece rilevanti lo SKU specifico, il numero di core, la frequenza di clock, i requisiti termici e il livello di parallelismo previsto. Una variante con molti core pu\u00f2 essere adatta a numerosi tenant ben delimitati, mentre un modello con caratteristiche diverse pu\u00f2 risultare pi\u00f9 indicato per un numero minore di applicazioni ad alta intensit\u00e0 di calcolo. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Intel suddivide la linea Xeon 6 in varianti con P-Core ed E-Core. I P-Core sono progettati per garantire elevate prestazioni per singolo core e supportano, tra l\u2019altro, AVX-512 e AMX. Ci\u00f2 pu\u00f2 risultare rilevante qualora il software utilizzato sfrutti effettivamente queste funzioni vettoriali o matriciali; un normale stack PHP o di server web non ne trae automaticamente vantaggio. Gli E-Core, invece, puntano a un\u2019elevata densit\u00e0 di core e a un throughput parallelo. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Per i carichi di lavoro condivisi o cloud molto intensi e ben isolati, i core Xeon 6-E possono quindi essere presi in considerazione. Anche i core Xeon 6-P o i modelli EPYC 9005 opportunamente configurati sono candidati ideali per carichi di lavoro che richiedono una maggiore potenza per singolo core. Si tratta di una classificazione dell\u2019orientamento del prodotto, non di una garanzia di prestazioni. L\u2019espansione della RAM, il firmware e la configurazione software possono influenzare in modo significativo il risultato e falsare un confronto tra i tipi di core senza una configurazione identica della piattaforma.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"ressourcen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"ressourcen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">I semi sono solo uno dei fattori<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I core della CPU esprimono appieno il loro potenziale solo se la memoria e l\u2019I\/O sono all\u2019altezza. I canali DDR5, insieme al numero di moduli e al tipo di DIMM, determinano la larghezza di banda di memoria disponibile; la capacit\u00e0 della RAM, invece, limita il numero di macchine virtuali, buffer di database o cache che possono essere gestiti senza ricorrere allo swap. Le linee PCIe collegano unit\u00e0 NVMe, schede di rete ed eventuali acceleratori. Per l\u2019hosting, questa catena deve essere progettata come un sistema integrato.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">AMD dichiara per l\u2019EPYC 9005 fino a dodici canali DDR5 e, a seconda del numero di socket e della piattaforma, un\u2019ampia connettivit\u00e0 PCIe Gen 5. Per i sistemi a socket singolo sono indicati fino a 128 lane PCIe Gen 5. Anche Intel Xeon 6 offre, a seconda della serie, fino a dodici canali DDR5; alcune configurazioni P-Core a socket singolo raggiungono fino a 136 linee PCIe. Questi valori si riferiscono ai dati relativi ai modelli e alle piattaforme e non costituiscono una garanzia delle prestazioni di un\u2019applicazione.  <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-1024x683.webp\" class=\"wp-image-21714\" alt=\"Topologia schematica della piattaforma con CPU, memoria di lavoro, unit\u00e0 NVMe e schede di rete.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/hosting-io-topologie-ram-nvme-c5bed1a2-detail1-4a0a3d0bfb.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">I canali di memoria e i percorsi PCIe contribuiscono a determinare se la capacit\u00e0 della CPU possa essere sfruttata nell\u2019hosting.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un nodo VPS dotato di pi\u00f9 SSD NVMe, due schede di rete veloci e numerose macchine virtuali mette in evidenza la differenza concreta. Se le unit\u00e0 o le schede di rete sono collegate tramite switch PCIe, potrebbero condividere un unico uplink. Anche la ripartizione delle lane, gli slot, la biforcazione, il supporto CXL e la configurazione del firmware effettivamente abilitata sono determinati dalla scheda madre. La capacit\u00e0 della CPU documentata deve quindi essere confrontata con lo schema a blocchi e la convalida del server specifico. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Nei sistemi con pi\u00f9 nodi NUMA, \u00e8 inoltre fondamentale considerare dove sono assegnati la RAM, le CPU virtuali e i dispositivi I\/O. Se una macchina virtuale o un database accede frequentemente alla memoria di un altro nodo, possono verificarsi latenze aggiuntive. \u00c8 quindi opportuno effettuare misurazioni in condizioni di carico realistiche: il solo carico della CPU non evidenzia n\u00e9 colli di bottiglia nella memoria n\u00e9 code sullo storage o sulla rete.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Molte lane facilitano il collegamento diretto di numerosi dispositivi, ma non garantiscono n\u00e9 una bassa latenza del database n\u00e9 elevate velocit\u00e0 di transazione. Il controller, il firmware degli SSD, la configurazione RAID o di replica, la profondit\u00e0 della coda e il percorso di rete rimangono fattori determinanti. La scelta tra <strong style=\"font-weight:700;color:inherit\">Hosting AMD EPYC<\/strong> e, nel caso di un server Intel Xeon, dovrebbe quindi tenere conto in modo altrettanto preciso dei requisiti di I\/O e di memoria, oltre che del numero di core e della frequenza di clock.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"workload-matrix\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"workload-matrix\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Sincronizzare i carichi di lavoro con la piattaforma<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La scelta non parte dal produttore, ma dalla distribuzione del carico di lavoro. Lo Xeon 6 con E-Core \u00e8 in linea di massima indicato per un gran numero di attivit\u00e0 indipendenti tra loro e ben delimitate; lo Xeon 6 con P-Core per esigenze relative a <strong style=\"font-weight:700;color:inherit\">Prestazioni per core<\/strong> e determinate operazioni vettoriali o matriciali. L\u2019EPYC 9005 copre inoltre diversi profili di core e di clock. Da ci\u00f2 non deriva alcuna gerarchia: sono determinanti lo SKU specifico, la topologia del server e il carico applicativo misurato.   <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Criteri di selezione in base al carico di lavoro di hosting\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Criteri di selezione in base al carico di lavoro di hosting<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Carico di lavoro<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Criterio principale relativo alla CPU<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Criterio fondamentale della piattaforma<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Punti di strozzatura tipici<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Valori di misura richiesti<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">hosting condiviso<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Elevato grado di parallelismo con limiti di conto efficaci<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">RAM per account, scheduler e limiti di I\/O<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Singoli account consumano risorse della CPU, della RAM o dell'I\/O del disco<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Tempo di risposta p95, processi attivi, coda di esecuzione, limitazione della CPU e tempo di attesa I\/O; Steal-Time solo su host virtualizzato<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">CMS e negozi online<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Prestazioni per ogni worker PHP attivo, oltre a un livello adeguato di parallelismo<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Cache degli oggetti veloce, RAM del database e latenza NVMe<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Code PHP-FPM, query lente, errori di cache<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">p95\/p99 - Tempo di richiesta, carico dei worker, tempo di interrogazione, percentuale di hit della cache<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">VPS e cloud<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Densit\u00e0 di core o prestazioni garantite per ogni vCPU in base al piano tariffario<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Layout NUMA, capacit\u00e0 della RAM, rete e QoS dello storage<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Overbooking della CPU, allocazione non uniforme della RAM, competizione per lo spazio di archiviazione<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Latenza guest, IOPS, throughput, latenza di rete, nonch\u00e9 \u2013 a seconda dell\u2019hypervisor \u2013 tempo di disponibilit\u00e0 della CPU, Run-Queue, Steal-Time o metriche di scheduling analoghe<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Database e Redis<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Prestazioni della cache e della memoria, in funzione del parallelismo<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Espansione DDR5, affinit\u00e0 NUMA e connessione diretta allo storage<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">RAM insufficiente, accessi NUMA remoti, NVMe lento o sovraccarico<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Latenza delle query o dei comandi, hit del buffer pool, latenza I\/O, larghezza di banda della memoria<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Servizi correlati a NVMe<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">CPU adeguata per il carico di protocollo e di test<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Topologia PCIe, numero di collegamenti diretti alle unit\u00e0 e alle schede di rete<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Switch PCIe, code, limiti di rete o di replica<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">p99 - Latenza I\/O, profondit\u00e0 della coda, IOPS, throughput, carico di rete<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Nell\u2019hosting condiviso, un\u2019elevata densit\u00e0 di core \u00e8 utile solo se i limiti relativi al tempo di CPU, ai processi, alla memoria RAM e alle operazioni I\/O proteggono effettivamente gli account vicini. I modelli E-Core possono quindi essere adatti ad ambienti multi-tenant fortemente parallelizzati. Anche un modello EPYC 9005 con un profilo di core adeguato pu\u00f2 risultare idoneo. Per singole istanze di e-shop o CMS particolarmente esigenti, invece, i tempi di risposta per singolo worker e il database sono pi\u00f9 importanti del semplice numero di core disponibili.   <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I nodi VPS e i servizi correlati allo storage richiedono inoltre una verifica dei <strong style=\"font-weight:700;color:inherit\">Topologia I\/O<\/strong>. L\u2019EPYC 9005 offre, a seconda della piattaforma, ampie risorse DDR5 e PCIe 5.0; anche lo Xeon 6 offre canali di memoria e lane PCIe che variano in base alla serie e al modello. Questi dati facilitano la preselezione, ma non garantiscono n\u00e9 una determinata latenza NVMe n\u00e9 una specifica velocit\u00e0 di trasmissione dei dati del database. La scheda madre, la configurazione, il firmware e il percorso software rimangono fattori determinanti nella decisione.   <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"benchmark-protokoll\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"benchmark-protokoll\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Pianificare correttamente i benchmark della CPU per l'hosting<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Il termine di ricerca <strong style=\"font-weight:700;color:inherit\">benchmark della CPU per hosting<\/strong> porta a una semplificazione inammissibile: un risultato relativo alla CPU non descrive un\u2019offerta di hosting. SPEC considera i risultati come quelli di sistemi completi e richiede la divulgazione dei dettagli configurativi essenziali. Per un confronto tra piattaforme, \u00e8 quindi necessario testare entrambi i candidati con un numero di socket, una dotazione di memoria, uno spazio di archiviazione, una rete e un software comparabili.  <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Protocollo di benchmark riproducibile per piattaforme di hosting\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Protocollo di benchmark riproducibile per piattaforme di hosting<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Obiettivo del test<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Generatore di carico o utensile<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Variabile misurata<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Informazioni obbligatorie sull'ambiente circostante<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Criteri di esclusione<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">PHP-FPM e il server web<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Carico HTTP rappresentativo con percorsi anonimizzati e tempi di risposta realistici<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Richieste al secondo, latenza p95\/p99, tasso di errore<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Modello della CPU, RAM, NVMe, rete, sistema operativo, kernel, server web, versione PHP e pool FPM<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Solo risposte statiche, cache diverse o limiti diversi per i worker<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Banca dati<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Richieste orientate all\u2019applicazione e volume di dati definito<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Tempo di interrogazione, transazioni, latenza p95\/p99, tempo di attesa I\/O<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Inoltre: versione del database, parametri, buffer pool, indici, dimensione dei record e modalit\u00e0 di replica<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Cache a caldo su una sola piattaforma o set di dati disomogenei<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Densit\u00e0 dei VPS<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Ospiti definiti con carico identico e prenotazione delle risorse<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Latenza guest, throughput, IOPS e, a seconda dell\u2019hypervisor e del sistema operativo guest, tempo di disponibilit\u00e0 della CPU, steal time, run queue o metriche di scheduling analoghe<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Inoltre: hypervisor, sistema operativo ospite, pinning della CPU, mappatura NUMA, prenotazione della RAM e QoS dello storage<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Diverso tasso di overbooking, diversa topologia delle vCPU, diversa metodologia di misurazione o diverso carico di fondo dell'host<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Per PHP-FPM, un elevato throughput delle richieste non \u00e8 sufficiente. Una piattaforma pu\u00f2 fornire molte risposte con un carico sintetico di breve durata e tuttavia generare valori p99 elevati in presenza di cronjob eseguiti in parallelo o di query al database lente. \u00c8 quindi necessario monitorare separatamente le code di attesa, i tassi di errore e i tempi di risposta per le pagine dinamiche e quelle memorizzate nella cache. Le distribuzioni con controllo di versione aiutano a documentare in modo univoco l\u2019applicazione e la configurazione testate. <a href=\"https:\/\/webhosting.de\/it\/web-hosting-con-supporto-git-miglior-fornitore-2025-codice\/\">Flussi di lavoro Git nell'hosting<\/a><\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Nel caso dei database, \u00e8 necessario documentare la dimensione dei record e lo stato della cache, poich\u00e9 un test eseguito interamente in RAM mostra limiti diversi rispetto a un funzionamento con un carico elevato di operazioni di I\/O. Per quanto riguarda la densit\u00e0 dei VPS, \u00e8 determinante anche l\u2019esperienza nel sistema ospite. Quale metrica di scheduling sia significativa dipende dall\u2019hypervisor e dal sistema operativo ospite; il tempo di CPU Ready non deve quindi essere considerato un parametro universalmente valido. Ripeti i test di carico e registra in modo trasparente il metodo di misurazione e le eventuali discrepanze.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"konfigurationscheck\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"konfigurationscheck\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Verifica della configurazione e della topologia<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Prima di effettuare un confronto, \u00e8 necessario valutare lo stato attuale. Ci\u00f2 evita che una presunta differenza a livello di CPU sia in realt\u00e0 dovuta a una diversa assegnazione NUMA, a una memoria diversa o a una configurazione modificata del server web. I comandi seguenti leggono informazioni o verificano le configurazioni; non modificano n\u00e9 l\u2019assegnazione delle CPU n\u00e9 le impostazioni dei servizi. Eseguili con le autorizzazioni richieste dal rispettivo sistema e archivia i risultati in modo protetto.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Con <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">lscpu<\/code> Si documentano il modello della CPU, le CPU logiche, il socket, i core e i nodi NUMA rilevati. <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">numactl --hardware<\/code> se lo strumento \u00e8 installato, integra le CPU disponibili e la memoria per ciascun nodo NUMA. Entrambe le uscite descrivono la topologia hardware rilevata, non l\u2019effettivo carico di lavoro in condizioni di carico di hosting. <\/p>\n<div class=\"wh-code-window\" data-wh-code style=\"margin:28px 0 34px;border:1px solid #2c4656;border-radius:12px;overflow:hidden;background:#132a3b;box-shadow:0 9px 25px -13px rgba(15,35,55,.2)\"><div class=\"wh-code-toolbar\" style=\"display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:10px;padding:11px 16px;background:#223e50;color:#edf5fa;font-size:13px;line-height:1.5;font-weight:600\"><span>Terminale<\/span><button type=\"button\" class=\"wh-code-copy\" data-wh-copy hidden style=\"padding:6px 11px;border:1px solid #7893a1;border-radius:6px;background:transparent;color:#fff;font-size:12px;line-height:1.5;font-weight:600;cursor:pointer\">Copia il codice<\/button><span class=\"wh-copy-status\" aria-live=\"polite\"><\/span><span data-wh-copy-success hidden>Copiato<\/span><span data-wh-copy-fallback hidden>Codice evidenziato \u2013 copiare<\/span><\/div><pre class=\"wh-code\" data-no-translation translate=\"no\" style=\"display:block;margin:0;padding:20px;max-width:100%;overflow-x:auto;color:#edf5fa;background:#132a3b;font:14px\/1.75 ui-monospace,SFMono-Regular,Menlo,Consolas,monospace;white-space:pre;direction:ltr;text-align:left\"><code class=\"language-bash\" style=\"font:inherit;color:inherit;background:transparent;padding:0;border:0;white-space:inherit\">lscpu\nnumactl --hardware\nnginx -T\nphp-fpm -tt<\/code><\/pre><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">L'appello <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">nginx -T<\/code> visualizza la configurazione NGINX attualmente in uso e pu\u00f2 quindi contenere nomi host interni, percorsi di file o riferimenti a certificati. Controlla e correggi tali informazioni prima di diffondere l'output. <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">php-fpm -tt<\/code> \u00e8 un esempio di verifica della configurazione; il nome del file binario e le opzioni variano a seconda della distribuzione e della versione di PHP. Verifica prima la versione disponibile localmente, invece di modificare una configurazione di produzione. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un caso pratico relativo ai VPS ne illustra lo scopo: se le vCPU di una VM sono assegnate ai core di un nodo NUMA, ma la RAM loro riservata si trova prevalentemente sull\u2019altro nodo, gli accessi alla memoria potrebbero subire una latenza aggiuntiva. Documentare quindi <strong style=\"font-weight:700;color:inherit\">Pinning della CPU<\/strong> e l\u2019allocazione della RAM. Solo in seguito sar\u00e0 possibile valutare se sia necessaria un\u2019altra piattaforma CPU o, in un primo momento, una topologia guest pi\u00f9 coerente. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"virtualisierung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"virtualisierung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Gestire la virtualizzazione in modo sicuro e pianificabile<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Nel caso delle offerte VPS e cloud, non \u00e8 solo il nome del processore a determinare le prestazioni percepite. <strong style=\"font-weight:700;color:inherit\">Pinning della CPU<\/strong> Assegna le vCPU a core fisici specifici in base alle esigenze, riducendo cos\u00ec le fluttuazioni nei tempi di esecuzione. Si tratta tuttavia di una scelta in termini di capacit\u00e0: i core riservati in modo esclusivo non sono disponibili per una distribuzione flessibile ad altri clienti. Per i piani tariffari con potenza di calcolo garantita, tale riserva dovrebbe quindi essere inclusa nella pianificazione del carico di lavoro.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Altrettanto importante \u00e8 la <strong style=\"font-weight:700;color:inherit\">Affinit\u00e0 NUMA<\/strong> su sistemi multi-socket o con un numero elevato di core. Una VM dovrebbe, per quanto possibile, utilizzare core e memoria RAM provenienti dallo stesso nodo NUMA. Se accede regolarmente alla memoria di un altro nodo, i percorsi di accesso aggiuntivi possono aumentare la latenza. Pertanto, \u00e8 consigliabile progettare le VM di grandi dimensioni tenendo conto innanzitutto della capacit\u00e0 della RAM locale e dell\u2019allocazione dei core, anzich\u00e9 considerare solo la somma di tutti i core e della memoria totale.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-1024x683.webp\" class=\"wp-image-21715\" alt=\"Esempio semplificato di pi\u00f9 domini NUMA con macchine virtuali, core CPU e memoria assegnati localmente.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/09\/numa-affinitaet-vps-hosting-c5bed1a2-detail2-a135b03f92.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">I domini NUMA dipendono dal processore, dalla piattaforma e dal firmware; un\u2019assegnazione adeguata pu\u00f2 ridurre gli accessi remoti non necessari alla memoria.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">La RAM riservata impedisce che la capacit\u00e0 di memoria garantita derivi esclusivamente da un sovraprenotazione ottimistica. Inoltre, limita <strong style=\"font-weight:700;color:inherit\">QoS dello storage<\/strong> IOPS, throughput o code per ogni VM, in modo che un backup, un\u2019importazione di database o un guest configurato in modo errato non blocchino il pool NVMe condiviso. Imposta limiti di sovraallocazione separati per CPU, RAM e storage: una quota CPU sostenibile non rende un nodo resiliente se il suo storage genera gi\u00e0 tempi di attesa elevati durante i picchi di carico.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Per le macchine virtuali riservate, entrambe le piattaforme offrono funzionalit\u00e0 che vanno oltre la virtualizzazione tradizionale. AMD documenta per EPYC 9005 le tecnologie SEV, SEV-ES e SEV-SNP; SEV-SNP integra meccanismi di protezione contro specifici attacchi alle tabelle di pagina e all\u2019allocazione della memoria.   Intel descrive TDX come una tecnologia che isola il sistema operativo ospite e le applicazioni della macchina virtuale dall\u2019host cloud, dall\u2019hypervisor e dalle altre macchine virtuali presenti sulla piattaforma.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Tali funzionalit\u00e0 non rendono automaticamente pi\u00f9 sicuri n\u00e9 i server AMD EPYC n\u00e9 quelli Intel Xeon. Per Intel TDX, \u00e8 necessario verificare i processori supportati, la configurazione DIMM adeguata e la piattaforma OEM o ODM specifica; i requisiti documentati relativi alle DIMM possono variare a seconda dell\u2019implementazione della piattaforma.   Inoltre, l\u2019utilizzabilit\u00e0 presuppone un\u2019interazione coordinata tra firmware, hypervisor, kernel, sistema operativo guest e processi operativi. Verifica inoltre il ciclo di vita delle chiavi, la certificazione, il ripristino e il monitoraggio. Senza queste procedure, una funzione hardware attivata non pu\u00f2 soddisfare pienamente i requisiti di protezione di un cliente.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"fehlerquellen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"fehlerquellen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Fonti di errore durante il confronto e il funzionamento<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un confronto attendibile parte da sistemi di dimensioni equivalenti. Un server a due socket non deve essere messo a confronto con un sistema a un solo socket quando la scelta di acquisto riguarda una classe di piattaforme. Per ogni test, registra il modello della CPU, il numero di socket, i core attivi, la quantit\u00e0 di RAM e la configurazione delle DIMM. Solo cos\u00ec sar\u00e0 possibile stabilire se un risultato \u00e8 dovuto all\u2019architettura, a componenti hardware aggiuntivi o a una configurazione diversa.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Anche memorie e I\/O non uniformi possono falsare le conclusioni. Differenze nell\u2019assegnazione dei canali DDR5, nelle generazioni NVMe, nella configurazione RAID, nelle schede di rete o nei profili energetici del BIOS modificano in modo significativo la velocit\u00e0 di trasferimento e le latenze. AMD sottolinea che, per l\u2019EPYC 9005, la configurazione I\/O specifica dipende dalla piattaforma e dalla scheda madre; la capacit\u00e0 dell\u2019interfaccia documentata non costituisce quindi una garanzia per l\u2019applicazione.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Sebbene un numero elevato di linee PCIe faciliti il collegamento diretto di pi\u00f9 unit\u00e0 NVMe e schede di rete veloci, non garantisce una bassa latenza del database: le code nello storage, il firmware del controller, la replica, i parametri del database e il set di lavoro nella RAM rimangono fattori determinanti. Per le architetture vicine allo storage, l\u2019articolo integra <a href=\"https:\/\/webhosting.de\/it\/iot-webhosting-edge-sicurezza-della-rete-confronto-societa-digitale\/\">Web hosting per piattaforme IoT<\/a> la prospettiva relativa alla latenza di rete, alla segmentazione e ai percorsi di memoria.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Anche i clock boost isolati non costituiscono un benchmark per l\u2019hosting. AMD definisce il boost massimo come la frequenza che un singolo core pu\u00f2 raggiungere in condizioni normali di funzionamento del server; in caso di carico parallelo continuo si applicano condizioni termiche ed energetiche diverse.   Pertanto, \u00e8 opportuno valutare i percentili dei tempi di risposta e la velocit\u00e0 effettiva in condizioni di concorrenza rappresentative, anzich\u00e9 dedurre le prestazioni di un intero nodo da un singolo valore di frequenza.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Il TDP, infatti, non \u00e8 una misura del consumo effettivo del server. Per le stime dei costi, ti servono i valori di misura dell'intero sistema con la RAM, lo spazio di archiviazione, il carico di rete e il profilo energetico selezionati. Il <strong style=\"font-weight:700;color:inherit\">Comparabilit\u00e0<\/strong> I risultati resi pubblici richiedono inoltre informazioni complete sul sistema; SPEC considera espressamente i risultati come relativi a sistemi completi, non a singoli processori.  <\/p>\n<aside class=\"wh-callout wh-callout-warning\" style=\"display:block;margin:28px 0;padding:20px 23px;border:1px solid #d1e4dd;border-left:4px solid #187065;border-radius:11px;background:#f0f7f4\"><p class=\"wh-callout-title\" style=\"margin:0 0 8px;color:#1c5c53;font-size:16px;font-weight:700;line-height:1.5\">Separare chiaramente i dati relativi agli acquisti<\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I dati forniti dal produttore in merito a prestazioni, consolidamento o TCO si riferiscono alla configurazione di riferimento descritta in ciascun caso. Non considerarli come una previsione generale applicabile a uno stack di hosting diverso.<\/p>\n<\/aside><\/section><section class=\"wh-section\" aria-labelledby=\"entscheidung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"entscheidung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Decidere gli acquisti in base a requisiti misurabili<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Documenta innanzitutto il profilo di carico: numero e dimensioni dei clienti, concorrenza tipica e massima, percentuale di PHP o dell\u2019applicazione, query al database, percentuale di hit della cache, RAM per istanza, nonch\u00e9 picchi di I\/O e di rete. Da ci\u00f2 non deriva una classifica astratta, bens\u00ec un catalogo dei requisiti. Solo questo potr\u00e0 indicare se siano determinanti un\u2019elevata densit\u00e0 di core, tempi di risposta brevi dei singoli worker o una connessione di storage particolarmente capiente.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Stabilisci quindi se intendi ampliare una piattaforma esistente, valutare sistemi usati o in magazzino oppure procurarti una configurazione server completamente nuova. Per EPYC 9005 e Xeon 6 \u00e8 necessario verificare la disponibilit\u00e0, le approvazioni OEM, la manutenzione del firmware e la pianificazione dei ricambi per il modello di server specifico. La denominazione della famiglia di CPU da sola non garantisce n\u00e9 la disponibilit\u00e0 n\u00e9 la convalida delle dotazioni desiderate in termini di RAM, storage e rete.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Confronta quindi gli SKU specifici, compresa la topologia del socket e la piattaforma server. Per l\u2019AMD EPYC 9005 occorre verificare la variante di core, il modello e l\u2019espansione prevista per DDR5 e PCIe. La famiglia comprende modelli Zen-5 e Zen-5c, le cui caratteristiche non possono essere equiparate in modo generalizzato.   Per quanto riguarda Intel Xeon 6, occorre distinguere in particolare tra le varianti P-Core ed E-Core, poich\u00e9 perseguono obiettivi diversi in termini di prestazioni per core e densit\u00e0 dei core.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Verifica la configurazione come elenco completo dei componenti: configurazione DIMM convalidata, RAM locale per nodo NUMA, numero e collegamento delle unit\u00e0 NVMe, schede di rete, switch PCIe, nonch\u00e9 sistema di raffreddamento e alimentatori. Un <strong style=\"font-weight:700;color:inherit\">Nodo di hosting EPYC-9005<\/strong> \u00c8 ovvio che una configurazione concretamente disponibile offra la combinazione richiesta di core, canali di memoria e I\/O. Si tratta di una verifica dell\u2019idoneit\u00e0 della SKU e della piattaforma server selezionate, non di un vantaggio prestazionale generale rispetto a Intel Xeon.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Un server Intel Xeon 6 con E-Core pu\u00f2 rappresentare un\u2019opzione plausibile per molti carichi di lavoro ben definiti e indipendenti. I modelli con P-Core sono invece da prendere in considerazione quando singole applicazioni richiedono elevate prestazioni per core o quando sono rilevanti funzioni vettoriali e matriciali adeguate. Intel cita AVX-512 e AMX per i P-Core Xeon 6; tuttavia, l\u2019utilit\u00e0 di queste funzioni dipende dal software utilizzato e dalla sua implementazione concreta.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Prima di effettuare l'ordine, esegui un test riproducibile utilizzando le tue immagini, le tue configurazioni e volumi di dati realistici. Oltre alle richieste al secondo, registra anche il tasso di errore, i percentili dei tempi di risposta, i tempi di attesa del database, le latenze di archiviazione e il comportamento in caso di backup paralleli o guasti. Sono necessarie informazioni complete su hardware e software affinch\u00e9 le decisioni successive rimangano comprensibili.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A <strong style=\"font-weight:700;color:inherit\">Fase pilota<\/strong> \u00c8 opportuno farlo quando la densit\u00e0 prevista dei mandanti, le nuove funzionalit\u00e0 dell\u2019hypervisor, un design NVMe insolito o i costi energetici influenzano in modo significativo il calcolo. A tal fine, gestisci un gruppo limitato e rappresentativo di clienti o un gruppo di test con chiari limiti di risorse. Solo dopo aver osservato i picchi di carico, le riserve di capacit\u00e0 e i processi operativi \u00e8 possibile giustificare tecnicamente le proiezioni, gli acquisti e l\u2019implementazione.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Fonti e stato dell'arte<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Stato della ricerca: <time datetime=\"2026-09-24\">2026-09-24<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Aggiornamento tecnico: 24\/09\/2026. L'articolo mette a confronto esclusivamente AMD EPYC 9005 e Intel Xeon 6; i dati relativi ad altre generazioni e linee di prodotti devono essere verificati separatamente. La presentazione del prodotto, gli SKU delle CPU disponibili e i sistemi server effettivamente reperibili e convalidati non sono da considerarsi equivalenti. Le informazioni relative a canali, linee PCIe e funzioni di sicurezza dipendono sempre dal modello e dalla piattaforma. Nota sulle fonti: nel PDF relativo all\u2019EPYC 9005 della serie S2, il titolo dei metadati del PDF incorporato potrebbe apparire come \u201eAMD EPYC 4004 Series Processors\u201c; l\u2019URL invariato e il contenuto visibile del documento si riferiscono tuttavia all\u2019AMD EPYC 9005.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.intel.com\/content\/www\/us\/en\/products\/docs\/xeon-6-product-brief.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/content\/dam\/amd\/en\/documents\/epyc-business-docs\/datasheets\/amd-epyc-9005-series-processor-datasheet.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.spec.org\/cpu2026\/docs\/runrules.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.amd.com\/content\/dam\/amd\/en\/documents\/epyc-technical-docs\/user-guides\/58462_amd-epyc-9005-tg-architecture-overview.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.amd.com\/api\/khub\/documents\/UIqhAbjRhgnzgzzdVU4pUw\/content<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/cc-enabling.trustedservices.intel.com\/intel-tdx-enabling-guide\/03\/hardware_selection\/<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>Non \u00e8 possibile valutare in modo generalizzato le prestazioni di AMD EPYC 9005 e Intel Xeon 6 per l'hosting web. Sono determinanti il modello di hosting, lo SKU specifico, la topologia della RAM e dell'I\/O, il layout NUMA e le misurazioni effettuate con un carico rappresentativo.<\/p>","protected":false},"author":1,"featured_media":21713,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[676],"tags":[],"class_list":["post-21708","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-server_vm"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/posts\/21708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/comments?post=21708"}],"version-history":[{"count":5,"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/posts\/21708\/revisions"}],"predecessor-version":[{"id":21716,"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/posts\/21708\/revisions\/21716"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/media\/21713"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/media?parent=21708"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/categories?post=21708"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/it\/wp-json\/wp\/v2\/tags?post=21708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}