{"id":21961,"date":"2026-11-02T14:20:00","date_gmt":"2026-11-02T13:20:00","guid":{"rendered":"https:\/\/webhosting.de\/?p=21961"},"modified":"2026-10-30T12:49:30","modified_gmt":"2026-10-30T11:49:30","slug":"smartnics-na-aceleracao-da-rede-de-alojamento","status":"publish","type":"post","link":"https:\/\/webhosting.de\/pt\/smartnics-im-hosting-netzwerkbeschleunigung\/","title":{"rendered":"SmartNICs na hospedagem: como avaliar corretamente a acelera\u00e7\u00e3o de rede"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">Os SmartNICs justificam-se na \u00e1rea do alojamento n\u00e3o devido \u00e0s elevadas velocidades das portas, mas sim quando uma porta ocupada <strong style=\"font-weight:700;color:inherit\">Gargalo da CPU no percurso de dados da rede<\/strong> resultante de regras recorrentes, overlays, switches virtuais ou encripta\u00e7\u00e3o. O fator decisivo \u00e9 se a placa, o firmware, os controladores e a plataforma reproduzem efetivamente e na \u00edntegra as correspond\u00eancias e a\u00e7\u00f5es necess\u00e1rias a n\u00edvel de hardware. Caso contr\u00e1rio, parte do processamento permanece no anfitri\u00e3o. Por isso, antes de qualquer aquisi\u00e7\u00e3o, a verifica\u00e7\u00e3o de compatibilidade, a comprova\u00e7\u00e3o do fluxo, o caminho de fallback e os custos do ciclo de vida devem ser considerados na mesma decis\u00e3o.  <\/p>\n<nav class=\"wh-toc\" aria-label=\"Conte\u00fado deste artigo\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">Ir diretamente para a sec\u00e7\u00e3o<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#smartnic-grundlagen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Como enquadrar corretamente os SmartNICs no contexto da hospedagem<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#datenpfad-und-offload\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Como o descarregamento de hardware altera o percurso dos dados<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#geeignete-hosting-szenarien\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Em que situa\u00e7\u00f5es as SmartNICs s\u00e3o \u00fateis na hospedagem<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#eignung-nach-einsatzfall\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Comparar os casos de utiliza\u00e7\u00e3o do ponto de vista t\u00e9cnico<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#integration-und-kompatibilitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Verificar a compatibilidade antes da implementa\u00e7\u00e3o<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#alternativen-und-kapazitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Comparar o SmartNIC com a CPU e o software<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#betrieb-und-monitoring\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Tornar vis\u00edvel o offload durante o funcionamento<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#fehlerbilder-und-rueckfall\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Padr\u00f5es t\u00edpicos de falhas e percursos de reca\u00edda<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#entscheidungsrahmen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Tomar decis\u00f5es realistas em mat\u00e9ria de aquisi\u00e7\u00e3o e explora\u00e7\u00e3o<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"smartnic-grundlagen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"smartnic-grundlagen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Como enquadrar corretamente os SmartNICs no contexto da hospedagem<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O termo <strong style=\"font-weight:700;color:inherit\">SmartNIC<\/strong> n\u00e3o \u00e9 um nome de produto padronizado de forma uniforme. Por isso, para o planeamento na hospedagem, o que \u00e9 determinante n\u00e3o \u00e9 a etiqueta, mas sim a fun\u00e7\u00e3o comprov\u00e1vel no percurso de dados: que pacotes, regras e t\u00faneis \u00e9 que a placa consegue processar, que tarefas permanecem a cargo do anfitri\u00e3o e que software controla as fun\u00e7\u00f5es? Uma velocidade elevada da porta n\u00e3o responde a estas quest\u00f5es.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Uma placa de rede cl\u00e1ssica fornece, acima de tudo, a liga\u00e7\u00e3o Ethernet e suporta fun\u00e7\u00f5es b\u00e1sicas de descarregamento comuns, como somas de verifica\u00e7\u00e3o ou segmenta\u00e7\u00e3o. Uma <strong style=\"font-weight:700;color:inherit\">SmartNIC<\/strong> alarga este \u00e2mbito com fun\u00e7\u00f5es especializadas ou program\u00e1veis de encaminhamento de dados. Estas podem incluir regras de fluxo, fun\u00e7\u00f5es de comuta\u00e7\u00e3o virtual, SR-IOV, processamento de t\u00faneis ou tarefas criptogr\u00e1ficas espec\u00edficas. No entanto, a disponibilidade destas fun\u00e7\u00f5es depende conjuntamente do modelo, do firmware, dos controladores e da integra\u00e7\u00e3o com a plataforma.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A <strong style=\"font-weight:700;color:inherit\">DPU<\/strong> tem, regra geral, uma arquitetura mais abrangente: al\u00e9m do ASIC de rede, disp\u00f5e de recursos computacionais pr\u00f3prios e pode operar um caminho de dados de infraestrutura separado. A NVIDIA descreve, para o BlueField, um modo DPU, no qual o sistema ARM integrado controla os recursos da NIC e o caminho de dados, bem como um modo NIC, no qual a placa se comporta como um adaptador perante o anfitri\u00e3o externo.  Assim, dependendo do modo de funcionamento, surge tamb\u00e9m uma \u00e1rea pr\u00f3pria de gest\u00e3o e confian\u00e7a.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Esta classifica\u00e7\u00e3o tem consequ\u00eancias pr\u00e1ticas para a aquisi\u00e7\u00e3o e a opera\u00e7\u00e3o. Uma placa com l\u00f3gica de c\u00e1lculo pr\u00f3pria n\u00e3o \u00e9 automaticamente a melhor escolha quando apenas s\u00e3o necess\u00e1rias transfer\u00eancias b\u00e1sicas simples. Por outro lado, um caminho de infraestrutura externo pode fazer sentido para a separa\u00e7\u00e3o de clientes ou para fun\u00e7\u00f5es de seguran\u00e7a, mas exige ent\u00e3o manuten\u00e7\u00e3o de firmware, conceitos de acesso, monitoriza\u00e7\u00e3o e processos de recupera\u00e7\u00e3o para componentes adicionais.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Mesmo uma porta de 100 GbE ou mais r\u00e1pida n\u00e3o garante qualquer acelera\u00e7\u00e3o das regras de firewall, das sobreposi\u00e7\u00f5es ou da encripta\u00e7\u00e3o. Os fatores decisivos s\u00e3o o tamanho dos pacotes, o n\u00famero de fluxos paralelos, a complexidade das regras e a quest\u00e3o de saber se as a\u00e7\u00f5es necess\u00e1rias podem, de facto, ser implementadas em hardware. S\u00f3 quando se comprovar que a CPU do servidor constitui um limite no percurso dos dados da rede \u00e9 que uma lista de funcionalidades se traduz num poss\u00edvel ganho de capacidade.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"datenpfad-und-offload\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"datenpfad-und-offload\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Como o descarregamento de hardware altera o percurso dos dados<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Sem um descarregamento adicional, um pacote chega inicialmente \u00e0 placa de rede f\u00edsica (NIC) e \u00e9, em seguida, processado pelo anfitri\u00e3o. Dependendo da arquitetura, passa pela pilha de rede do kernel, pela firewall, pela ponte ou pelo switch virtual, pelo encaminhamento e, se for o caso, pelo encapsulamento para uma sobreposi\u00e7\u00e3o. S\u00f3 depois disso \u00e9 que chega a uma VM, a um contentor ou a outra porta f\u00edsica. Cada etapa pode causar consumo de tempo de CPU e filas de espera.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Este percurso torna-se particularmente relevante no caso de muitos pacotes pequenos, de in\u00fameras liga\u00e7\u00f5es de curta dura\u00e7\u00e3o ou de pol\u00edticas de clientes extensas. N\u00e3o \u00e9 apenas a quantidade de dados transmitidos que sobrecarrega o anfitri\u00e3o, mas tamb\u00e9m o processamento repetido de pacotes e fluxos individuais. Por isso, \u00e9 <strong style=\"font-weight:700;color:inherit\">acelera\u00e7\u00e3o de rede<\/strong> n\u00e3o \u00e9 uma caracter\u00edstica geral de um servidor, mas sim um al\u00edvio espec\u00edfico de uma rota de dados concretamente identificada.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Em <strong style=\"font-weight:700;color:inherit\">Descarregamento de hardware<\/strong> Os componentes de controlo podem transferir regras de encaminhamento e filtragem v\u00e1lidas para um caminho de dados de hardware. O modelo \u00abswitchdev\u00bb do Linux descreve, para este efeito, a transfer\u00eancia do caminho de dados de encaminhamento do kernel para um dispositivo de comuta\u00e7\u00e3o. As regras que s\u00e3o efetivamente aplicadas dependem da placa espec\u00edfica, do seu controlador e da integra\u00e7\u00e3o de rede a montante. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A documenta\u00e7\u00e3o do OVS no ramo de desenvolvimento 4.0.90 descreve explicitamente uma sec\u00e7\u00e3o separada sobre o \u00abFlow Hardware Offload\u00bb como experimental. Para esta configura\u00e7\u00e3o espec\u00edfica do OVS com DPDK, a documenta\u00e7\u00e3o distingue entre a descarregamento total de correspond\u00eancias e a\u00e7\u00f5es e o descarregamento parcial, no qual apenas as correspond\u00eancias s\u00e3o descarregadas. Esta descri\u00e7\u00e3o n\u00e3o constitui uma prova de compatibilidade est\u00e1vel e universalmente v\u00e1lida para outras vers\u00f5es do OVS, placas de rede (NICs) ou plataformas. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Na pr\u00e1tica, cada declara\u00e7\u00e3o de offload deve, portanto, especificar o percurso concreto dos dados: vers\u00e3o do software utilizada, controladores, firmware, campos de correspond\u00eancia e a\u00e7\u00f5es. Um interruptor ativado n\u00e3o prova nem que os fluxos relevantes sejam transferidos, nem que os requisitos de seguran\u00e7a e a sem\u00e2ntica da rede continuem a ser cumpridos inalterados. No caso da filtragem de VLAN, por exemplo, o switchdev exige que o hardware cumpra as regras da VLAN de ponte e rejeite os IDs de VLAN n\u00e3o autorizados. O offload \u00e9, assim, a implementa\u00e7\u00e3o t\u00e9cnica das regras existentes, e n\u00e3o um atalho para as contornar.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"geeignete-hosting-szenarien\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"geeignete-hosting-szenarien\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Em que situa\u00e7\u00f5es as SmartNICs s\u00e3o \u00fateis na hospedagem<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Os SmartNICs revelam-se especialmente \u00fateis em plataformas de virtualiza\u00e7\u00e3o com muitas m\u00e1quinas virtuais (VM) e decis\u00f5es de encaminhamento recorrentes. O SR-IOV permite atribuir uma fun\u00e7\u00e3o virtual a uma VM; numa arquitetura switchdev, as interfaces Representor representam fun\u00e7\u00f5es f\u00edsicas ou virtuais no sistema operativo. As regras para o tr\u00e1fego entre estas portas podem, assim, ser implementadas em hardware.   No entanto, a utilidade depende das fun\u00e7\u00f5es necess\u00e1rias para as m\u00e1quinas virtuais.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Redes de sobreposi\u00e7\u00e3o com capacidade para m\u00faltiplos clientes e <strong style=\"font-weight:700;color:inherit\">Microsegmenta\u00e7\u00e3o<\/strong> constituem outro ponto de partida. Quando muitas redes de clientes aplicam repetidamente atribui\u00e7\u00f5es de VLAN ou de overlay, regras de controlo de acesso e decis\u00f5es semelhantes relativas aos fluxos, um percurso de dados de hardware adequado pode aliviar a carga das CPUs dos anfitri\u00f5es. A condi\u00e7\u00e3o pr\u00e9via continua a ser que o n\u00famero de regras, os campos de correspond\u00eancia e as a\u00e7\u00f5es estejam dispon\u00edveis na placa selecionada, juntamente com o controlador, e que a sem\u00e2ntica das pol\u00edticas seja totalmente preservada.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para a OpenShift Container Platform 4.22, a Red Hat documenta o descarregamento de hardware para n\u00f3s bare-metal com SmartNIC compat\u00edvel e o SR-IOV Network Operator ativo. Nesse contexto, apenas s\u00e3o suportadas a comunica\u00e7\u00e3o pod-a-pod e a comunica\u00e7\u00e3o pod-a-servi\u00e7o ClusterIP com pods normais; as aplica\u00e7\u00f5es DPDK n\u00e3o s\u00e3o compat\u00edveis com esta funcionalidade. Al\u00e9m disso, a vantagem limita-se a segmentos de comunica\u00e7\u00e3o cujos n\u00f3s envolvidos utilizem SmartNICs compat\u00edveis. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No caso de redes de host ou locais encriptadas, o offload IPsec pode assumir tarefas espec\u00edficas ou todo o processo de encapsulamento, desencapsulamento, encripta\u00e7\u00e3o e prote\u00e7\u00e3o contra repeti\u00e7\u00e3o. A NVIDIA documenta v\u00e1rios tipos de descarregamento para este fim, incluindo o descarregamento criptogr\u00e1fico e o descarregamento total. No entanto, isso n\u00e3o implica uma compatibilidade universal: o suporte e os limites de desempenho dependem do modelo, do firmware e do m\u00e9todo criptogr\u00e1fico utilizado.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Um servidor de alojamento web simples \u00e9, deliberadamente, um contra-exemplo. Se este fornecer, na sua maioria, respostas HTTP poucas mas de grande dimens\u00e3o e n\u00e3o apresentar carga de CPU no percurso dos pacotes, pode ser mais adequado um servidor mais especializado <strong style=\"font-weight:700;color:inherit\">hardware de servidor<\/strong> apenas geram custos operacionais adicionais. Em primeiro lugar, deve esclarecer-se se a causa do estrangulamento reside na aplica\u00e7\u00e3o, na base de dados, na mem\u00f3ria ou na rede. As SmartNICs n\u00e3o s\u00e3o uma boa op\u00e7\u00e3o para substituir este diagn\u00f3stico.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"eignung-nach-einsatzfall\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"eignung-nach-einsatzfall\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Comparar os casos de utiliza\u00e7\u00e3o do ponto de vista t\u00e9cnico<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A decis\u00e3o sobre se uma SmartNIC faz sentido n\u00e3o depende da velocidade nominal da porta, mas sim do percurso concreto dos dados. A sua utiliza\u00e7\u00e3o \u00e9 particularmente justificada quando muitas regras recorrentes, um elevado n\u00famero de fluxos ou fun\u00e7\u00f5es de overlay e de seguran\u00e7a ocupam constantemente o tempo da CPU do anfitri\u00e3o. A vantagem mant\u00e9m-se <strong style=\"font-weight:700;color:inherit\">dependente do percurso<\/strong>: Uma sec\u00e7\u00e3o acelerada s\u00f3 beneficia as liga\u00e7\u00f5es que s\u00e3o efetivamente estabelecidas atrav\u00e9s de hardware compat\u00edvel e regras suportadas. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Adequa\u00e7\u00e3o do descarregamento por SmartNIC em fun\u00e7\u00e3o do caso de utiliza\u00e7\u00e3o de alojamento\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Adequa\u00e7\u00e3o do descarregamento por SmartNIC em fun\u00e7\u00e3o do caso de utiliza\u00e7\u00e3o de alojamento<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Caso de utiliza\u00e7\u00e3o<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Poss\u00edvel vantagem<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Requisitos t\u00e9cnicos<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Restri\u00e7\u00e3o t\u00edpica<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Ponto de verifica\u00e7\u00e3o antes do lan\u00e7amento<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Alojamento de m\u00e1quinas virtuais com SR-IOV<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O reencaminhamento entre fun\u00e7\u00f5es virtuais pode ser efetuado atrav\u00e9s do eSwitch.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Placa adequada, controladores e integra\u00e7\u00e3o com o Representor ou o eSwitch.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">As funcionalidades de rede e a observabilidade das m\u00e1quinas virtuais podem sofrer altera\u00e7\u00f5es.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Testar as funcionalidades de m\u00e1quinas virtuais suportadas, as regras de seguran\u00e7a e a migra\u00e7\u00e3o.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">OpenShift 4.22 com OVN-Kubernetes<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Os percursos de servi\u00e7o Pod e ClusterIP documentados podem utilizar o descarregamento de hardware.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">N\u00f3s \u00abbare-metal\u00bb compat\u00edveis, SR-IOV Network Operator e configura\u00e7\u00e3o adequada do pod.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Apenas determinados tipos de comunica\u00e7\u00e3o s\u00e3o suportados; as aplica\u00e7\u00f5es DPDK n\u00e3o s\u00e3o compat\u00edveis com isto.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Comparar os percursos de pods, servi\u00e7os e n\u00f3s suportados pela vers\u00e3o da plataforma.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Redes de sobreposi\u00e7\u00e3o<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O processamento em tunel e regras de reencaminhamento simples podem reduzir a carga da CPU.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Apoio aos t\u00faneis, jogos e a\u00e7\u00f5es necess\u00e1rios.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">As a\u00e7\u00f5es n\u00e3o suportadas resultam numa transfer\u00eancia parcial ou na aus\u00eancia de transfer\u00eancia.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Verificar o formato do t\u00fanel, o \u00e2mbito das regras e a reca\u00edda no software.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">IPsec<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">A encapsula\u00e7\u00e3o, a desencapsula\u00e7\u00e3o e o trabalho criptogr\u00e1fico podem ser externalizados, dependendo do modelo.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Modelo de placa adequado, firmware e variante de descarregamento IPsec suportada.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">As funcionalidades e limita\u00e7\u00f5es dependem da gera\u00e7\u00e3o e da configura\u00e7\u00e3o.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Verificar se o modelo de destino possui capacidade comprovada de \u00abcrypto\u00bb ou de \u00abfull-offload\u00bb.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Percurso de dados de infraestrutura program\u00e1vel<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">\u00c9 poss\u00edvel implementar um processamento de fluxo especializado para as fun\u00e7\u00f5es adequadas.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">A integra\u00e7\u00e3o necess\u00e1ria de estados, controlos e plataformas deve ser concretamente apoiada.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">A descri\u00e7\u00e3o das funcionalidades fornecida por um fabricante n\u00e3o se aplica a outros SmartNICs.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Comparar concretamente a sem\u00e2ntica de correspond\u00eancia, de a\u00e7\u00e3o e de estado necess\u00e1ria.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Servidor de alojamento web simples<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">No m\u00e1ximo, al\u00edvio atrav\u00e9s das habituais transfer\u00eancias de carga do NIC.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">O percurso de dados da rede identificado como um ponto de estrangulamento.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">A carga das aplica\u00e7\u00f5es, das bases de dados ou do armazenamento n\u00e3o \u00e9 afetada.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Registar o perfil da CPU e da rede antes de realizar um investimento em hardware.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No caso das plataformas de virtualiza\u00e7\u00e3o, <strong style=\"font-weight:700;color:inherit\">SR-IOV<\/strong> Uma abordagem t\u00edpica: as fun\u00e7\u00f5es virtuais s\u00e3o atribu\u00eddas a uma VM, enquanto as interfaces Representor no sistema operativo mapeiam as portas dessas fun\u00e7\u00f5es. Desta forma, \u00e9 poss\u00edvel implementar em hardware as regras de reencaminhamento entre portas virtuais e f\u00edsicas numa arquitetura orientada para switchdev. No entanto, isto n\u00e3o substitui a verifica\u00e7\u00e3o de se a separa\u00e7\u00e3o de clientes pretendida e o modelo operacional s\u00e3o mantidos. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O Kubernetes \u00e9 o oposto de uma promessa gen\u00e9rica de acelera\u00e7\u00e3o. Para a integra\u00e7\u00e3o documentada com o OpenShift 4.22, aplicam-se determinados percursos de tr\u00e1fego suportados, n\u00f3s SmartNIC compat\u00edveis e requisitos de carga de trabalho. Se um n\u00f3 com capacidade de offload comunicar com um n\u00f3 normal, este \u00faltimo processa a sua parte no kernel, limitando assim o percurso total. Por conseguinte, uma implementa\u00e7\u00e3o deve, em primeiro lugar, ter em conta um conjunto de n\u00f3s delimitado e vias de comunica\u00e7\u00e3o reais. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No caso de redes de host ou locais encriptadas, estes termos devem ser utilizados com especial precis\u00e3o. As variantes documentadas do IPsec variam, consoante a plataforma, desde o \u00abCrypto-Offload\u00bb at\u00e9 ao \u00abFull Offload\u00bb para encapsulamento, desencapsulamento, encripta\u00e7\u00e3o e prote\u00e7\u00e3o contra repeti\u00e7\u00e3o. Da\u00ed n\u00e3o decorre qualquer garantia geral de d\u00e9bito: o modelo, o firmware, os algoritmos utilizados e as limita\u00e7\u00f5es espec\u00edficas do produto determinam qual o processamento que \u00e9 efetivamente externalizado.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"integration-und-kompatibilitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"integration-und-kompatibilitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Verificar a compatibilidade antes da implementa\u00e7\u00e3o<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A aquisi\u00e7\u00e3o come\u00e7a com um levantamento da situa\u00e7\u00e3o atual, sem altera\u00e7\u00f5es, e n\u00e3o com a ativa\u00e7\u00e3o de op\u00e7\u00f5es de offload. Registe o modelo exato da placa, incluindo o PCI-ID, a vers\u00e3o do firmware, os controladores e o kernel. Al\u00e9m disso, \u00e9 necess\u00e1rio conhecer o modo eSwitch, bem como a vers\u00e3o e a configura\u00e7\u00e3o do Open vSwitch, OVN, hipervisor ou plataforma Kubernetes, uma vez que a capacidade da placa, por si s\u00f3, n\u00e3o garante uma integra\u00e7\u00e3o completa do software.  <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-1024x683.webp\" class=\"wp-image-21965\" alt=\"A administradora verifica uma placa de rede PCIe antes de a integrar num servidor.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/smartnic-kompatibilitaet-pruefen-993a12dc-detail1-1f043679f9.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Imagem ilustrativa gerada por IA para o teste de hardware e plataforma antes da implementa\u00e7\u00e3o do offload.<\/figcaption><\/figure><div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Verifica\u00e7\u00e3o compacta de compatibilidade antes da implementa\u00e7\u00e3o do offload\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Verifica\u00e7\u00e3o compacta de compatibilidade antes da implementa\u00e7\u00e3o do offload<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">N\u00edvel de verifica\u00e7\u00e3o<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Informa\u00e7\u00f5es a recolher<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Por que \u00e9 relevante<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Hardware<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Modelo da placa, ID PCI e configura\u00e7\u00e3o da porta<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Define as fun\u00e7\u00f5es ASIC e as fun\u00e7\u00f5es virtuais dispon\u00edveis.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Firmware e controladores<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Vers\u00f5es exatas e kernel compat\u00edvel<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">A placa e o host necessitam de implementa\u00e7\u00f5es compat\u00edveis entre si.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Modo de percurso de dados<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Configura\u00e7\u00e3o do eSwitch e do switchdev<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Determina se as regras podem ser transferidas para um caminho de dados de um switch de hardware.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Comuta\u00e7\u00e3o virtual<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Vers\u00e3o do OVS, do OVN ou do hipervisor<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Determina quais as funcionalidades que o software pode solicitar para esta combina\u00e7\u00e3o.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Sem\u00e2ntica das regras<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Protocolos, t\u00faneis e a\u00e7\u00f5es necess\u00e1rios<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Apenas as regras represent\u00e1veis podem ser executadas na \u00edntegra em hardware.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Detec\u00e7\u00e3o e reca\u00edda<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Estado do fluxo, contador e recurso de fallback do software<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Permite identificar o descarregamento parcial e as regras n\u00e3o suportadas durante o funcionamento.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A sem\u00e2ntica de regra necess\u00e1ria deve estar dispon\u00edvel antecipadamente sob a forma de descri\u00e7\u00e3o do caminho de dados: por exemplo, atribui\u00e7\u00e3o de VLAN, IPv4 ou IPv6, TCP ou UDP, tipo de t\u00fanel, altera\u00e7\u00e3o de cabe\u00e7alho, reencaminhamento ou rejei\u00e7\u00e3o. A documenta\u00e7\u00e3o experimental do OVS 4.0.90 demonstra, no que diz respeito \u00e0 sua configura\u00e7\u00e3o DPDK, que a aus\u00eancia de a\u00e7\u00f5es de hardware pode conduzir a um descarregamento parcial. Da\u00ed decorre que, para qualquer outra vers\u00e3o ou plataforma, se trata apenas de uma tarefa de verifica\u00e7\u00e3o, n\u00e3o constituindo qualquer garantia quanto ao seu \u00e2mbito funcional. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">As matrizes de plataforma s\u00e3o <strong style=\"font-weight:700;color:inherit\">Certificados de compatibilidade espec\u00edficos para cada vers\u00e3o<\/strong>, sem fazer afirma\u00e7\u00f5es gerais sobre uma fam\u00edlia de placas de rede. O OpenShift 4.22 especifica placas de rede concretas para a sua integra\u00e7\u00e3o de descarregamento de hardware, incluindo a BlueField-2 no modo ConnectX-6. Da\u00ed n\u00e3o se pode deduzir o suporte a outro firmware, nem a outro modo de DPU, nem a uma distribui\u00e7\u00e3o diferente. Por isso, documente separadamente cada combina\u00e7\u00e3o de hardware, firmware, controlador e vers\u00e3o da plataforma. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No caso do switchdev do Linux, \u00e9 tamb\u00e9m fundamental que o hardware respeite a sem\u00e2ntica da rede de software. No caso da filtragem de VLAN, por exemplo, um switch que realiza o offload deve respeitar as regras de VLAN da ponte e rejeitar os IDs de VLAN n\u00e3o autorizados. Este requisito demonstra por que raz\u00e3o as listas de fun\u00e7\u00f5es e a pol\u00edtica de seguran\u00e7a devem ser verificadas em conjunto: a acelera\u00e7\u00e3o n\u00e3o pode criar uma segmenta\u00e7\u00e3o de rede diferente. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"alternativen-und-kapazitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"alternativen-und-kapazitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Comparar o SmartNIC com a CPU e o software<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Uma SmartNIC \u00e9 apenas uma das v\u00e1rias op\u00e7\u00f5es quando o processamento de rede est\u00e1 limitado. Em primeiro lugar, vale a pena verificar se uma maior capacidade da CPU, um n\u00famero adequado de filas, RSS, distribui\u00e7\u00e3o de IRQ ou ajuste do kernel j\u00e1 resolvem o estrangulamento. Para compreender melhor os SoftIRQs, as filas e a distribui\u00e7\u00e3o de interrup\u00e7\u00f5es, consulte o artigo sobre <a href=\"https:\/\/webhosting.de\/pt\/softirq-cpu-hosting-otimizacao-do-debito-da-rede-datacenter\/\">Rendimento da CPU e da rede no alojamento<\/a> princ\u00edpios adicionais. Sem a comprova\u00e7\u00e3o de um estrangulamento na rede, a necessidade de hardware especializado adicional permanece uma suposi\u00e7\u00e3o.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O DPDK e o AF_XDP podem encurtar os percursos de software nas CPUs do anfitri\u00e3o, mas cada um requer um planeamento espec\u00edfico da arquitetura e da CPU. A afirma\u00e7\u00e3o relativa ao polling cont\u00ednuo n\u00e3o pode ser aplicada de forma generalizada a ambas as abordagens: Na documenta\u00e7\u00e3o do OVS-DPDK relativa \u00e0 configura\u00e7\u00e3o descrita, um thread faz o polling cont\u00ednuo dos dispositivos DPDK, ocupando, ao faz\u00ea-lo, um n\u00facleo da CPU na totalidade. A mapeamento NUMA, o isolamento de n\u00facleos e as vers\u00f5es espec\u00edficas do OVS e do DPDK continuam, portanto, a fazer parte do projeto. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Mesmo uma placa de rede cl\u00e1ssica de servidor pode proporcionar descarregamento de carga suficiente para somas de verifica\u00e7\u00e3o, segmenta\u00e7\u00e3o ou funcionalidades espec\u00edficas de t\u00faneis. Esta op\u00e7\u00e3o \u00e9 adequada quando n\u00e3o s\u00e3o necess\u00e1rias regras extensas de switch virtual, segrega\u00e7\u00e3o de clientes ou percursos de dados de seguran\u00e7a implementados em hardware. As SmartNICs tornam-se especialmente vi\u00e1veis quando as fun\u00e7\u00f5es exigidas v\u00e3o al\u00e9m dessas caracter\u00edsticas b\u00e1sicas e s\u00e3o recorrentes a longo prazo.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O conceito de capacidade \u00e9 simples, mas importante: se, num host, os n\u00facleos da CPU estiverem a ser sobrecarregados pelo processamento de pacotes e se for poss\u00edvel descarregar totalmente uma parte representativa desses pacotes, poder\u00e1 surgir margem de manobra na CPU. No entanto, essa margem s\u00f3 conta como capacidade utiliz\u00e1vel se n\u00e3o houver um estrangulamento a seguir causado pela aplica\u00e7\u00e3o, pela mem\u00f3ria, pelo armazenamento ou por um plano de conting\u00eancia de software. N\u00e3o se trata de uma dedu\u00e7\u00e3o direta da taxa de liga\u00e7\u00e3o ou do pre\u00e7o da placa.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Por isso, compare as alternativas com base no mesmo perfil de carga: tamanhos dos pacotes, taxa de liga\u00e7\u00e3o, n\u00famero de regras, t\u00faneis, encripta\u00e7\u00e3o e pico de carga previsto. Ao faz\u00ea-lo, analise as percentagens de CPU do percurso dos dados separadamente do trabalho da aplica\u00e7\u00e3o e verifique quais os fluxos que realmente s\u00e3o processados em hardware. Um <strong style=\"font-weight:700;color:inherit\">Limita\u00e7\u00e3o da CPU<\/strong> A passagem por uma firewall, uma rede overlay ou um encaminhamento virtual constitui um motivo v\u00e1lido para avalia\u00e7\u00e3o; uma carga elevada do sistema em geral n\u00e3o o \u00e9.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"betrieb-und-monitoring\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"betrieb-und-monitoring\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Tornar vis\u00edvel o offload durante o funcionamento<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Ap\u00f3s a implementa\u00e7\u00e3o, n\u00e3o basta considerar uma op\u00e7\u00e3o de descarregamento como ativa. Uma demonstra\u00e7\u00e3o de funcionamento fi\u00e1vel associa o <strong style=\"font-weight:700;color:inherit\">Estado do fluxo<\/strong> com os contadores da placa, as taxas de perda e de erros, a utiliza\u00e7\u00e3o da CPU, bem como um perfil de carga semelhante ao tr\u00e1fego futuro. S\u00f3 em conjunto \u00e9 que estes dados revelam se os fluxos relevantes s\u00e3o efetivamente processados no hardware ou se o anfitri\u00e3o continua a suportar a parte decisiva do percurso dos dados.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para efeitos de compara\u00e7\u00e3o, os operadores devem considerar os mesmos tamanhos de pacotes, protocolos, n\u00famero de liga\u00e7\u00f5es e diretrizes, tanto antes como depois de uma altera\u00e7\u00e3o. A taxa de transfer\u00eancia em gigabits, por si s\u00f3, pode facilmente ocultar um estrangulamento no caso de pacotes pequenos ou de muitos fluxos paralelos. Igualmente importantes s\u00e3o a lat\u00eancia, o tempo de CPU por anfitri\u00e3o envolvido, a carga de Softirq, as perdas na fila e a distribui\u00e7\u00e3o do tr\u00e1fego pelos n\u00f3s e portas.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-1024x683.webp\" class=\"wp-image-21966\" alt=\"Portas de rede de um servidor em rack com cabos de fibra \u00f3tica ligados, durante uma inspe\u00e7\u00e3o t\u00e9cnica.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/server-netzwerkports-monitoring-993a12dc-detail2-5882ac87ce.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Imagem ilustrativa gerada por IA para a observa\u00e7\u00e3o de percursos f\u00edsicos de rede e das respetivas op\u00e7\u00f5es alternativas.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Os comandos seguintes n\u00e3o alteram nenhuma configura\u00e7\u00e3o. A primeira consulta tem em conta tanto os dispositivos PCI que aparecem como \u00abEthernet controller\u00bb como aqueles que aparecem como \u00abNetwork controller\u00bb. <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">ethtool -k<\/code> apresenta as funcionalidades de offload disponibilizadas ou ativadas no Netdev, mas n\u00e3o comprova de forma exaustiva nem o eSwitch, nem o SmartNIC, nem o offload de fluxos. As restantes sa\u00eddas s\u00e3o tamb\u00e9m dados de invent\u00e1rio e configura\u00e7\u00e3o, n\u00e3o constituindo prova de uma regra espec\u00edfica totalmente transferida.<\/p>\n<div class=\"wh-code-window\" data-wh-code style=\"margin:28px 0 34px;border:1px solid #2c4656;border-radius:12px;overflow:hidden;background:#132a3b;box-shadow:0 9px 25px -13px rgba(15,35,55,.2)\"><div class=\"wh-code-toolbar\" style=\"display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:10px;padding:11px 16px;background:#223e50;color:#edf5fa;font-size:13px;line-height:1.5;font-weight:600\"><span>Terminal<\/span><button type=\"button\" class=\"wh-code-copy\" data-wh-copy hidden style=\"padding:6px 11px;border:1px solid #7893a1;border-radius:6px;background:transparent;color:#fff;font-size:12px;line-height:1.5;font-weight:600;cursor:pointer\">Copiar c\u00f3digo<\/button><span class=\"wh-copy-status\" aria-live=\"polite\"><\/span><span data-wh-copy-success hidden>Copiado<\/span><span data-wh-copy-fallback hidden>C\u00f3digo destacado \u2013 por favor, copie<\/span><\/div><pre class=\"wh-code\" data-no-translation translate=\"no\" style=\"display:block;margin:0;padding:20px;max-width:100%;overflow-x:auto;color:#edf5fa;background:#132a3b;font:14px\/1.75 ui-monospace,SFMono-Regular,Menlo,Consolas,monospace;white-space:pre;direction:ltr;text-align:left\"><code class=\"language-bash\" style=\"font:inherit;color:inherit;background:transparent;padding:0;border:0;white-space:inherit\">lspci -nn | grep -Ei &#039;Ethernet controller|Network controller&#039;\nethtool -k &lt;interface&gt;\nethtool -i &lt;interface&gt;\ndevlink dev show\novs-vsctl get Open_vSwitch . other_config<\/code><\/pre><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No caso do Open vSwitch, \u00e9 importante distinguir, em particular, entre a acelera\u00e7\u00e3o por hardware configurada e o resultado observado. A documenta\u00e7\u00e3o de desenvolvimento do OVS 4.0.90 classifica a sua descarregamento de fluxo por hardware como experimental e descreve o descarregamento total ou parcial apenas para esta configura\u00e7\u00e3o do OVS com DPDK. Para o funcionamento em produ\u00e7\u00e3o, \u00e9, por isso, necess\u00e1rio avaliar as informa\u00e7\u00f5es de fluxo e os contadores de hardware em conjunto com os contadores de software do anfitri\u00e3o. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O monitoriza\u00e7\u00e3o requer, al\u00e9m disso, uma refer\u00eancia temporal. Um teste breve pode confirmar regras, enquanto um perfil pr\u00f3ximo da produ\u00e7\u00e3o pode, posteriormente, desencadear capacidades de tabelas, percursos de registo pouco frequentes ou reconfigura\u00e7\u00f5es. Por isso, faz sentido registar valores normais e anomalias por modelo de placa, firmware, controlador e vers\u00e3o da plataforma. Desta forma, ap\u00f3s as atualiza\u00e7\u00f5es, \u00e9 poss\u00edvel verificar se o <strong style=\"font-weight:700;color:inherit\">Percurso dos dados<\/strong> ou se apenas a carga observada se alterou.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Na integra\u00e7\u00e3o com o OpenShift 4.22, a vis\u00e3o deve, al\u00e9m disso, abranger todo o percurso de comunica\u00e7\u00e3o. O suporte documentado para descarregamento de hardware aplica-se apenas a determinadas cargas de trabalho e tipos de comunica\u00e7\u00e3o. Se um n\u00f3 compat\u00edvel comunicar com um n\u00f3 sem um SmartNIC adequado, este \u00faltimo processa a sua parte no kernel; os pontos de medi\u00e7\u00e3o num \u00fanico anfitri\u00e3o podem, ent\u00e3o, apresentar uma imagem incompleta do percurso de ponta a ponta. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"fehlerbilder-und-rueckfall\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"fehlerbilder-und-rueckfall\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Padr\u00f5es t\u00edpicos de falhas e percursos de reca\u00edda<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O erro mais comum \u00e9 <strong style=\"font-weight:700;color:inherit\">transfer\u00eancia incompleta<\/strong>. Um fluxo pode ser identificado no hardware com base em caracter\u00edsticas simples, mas, no caso de uma a\u00e7\u00e3o n\u00e3o suportada, tem de regressar parcial ou totalmente ao caminho do software. A documenta\u00e7\u00e3o experimental do OVS 4.0.90 descreve esta descarga parcial para a sua configura\u00e7\u00e3o DPDK. N\u00e3o se trata de uma afirma\u00e7\u00e3o geral aplic\u00e1vel a todas as instala\u00e7\u00f5es do OVS, mas ilustra o ponto de verifica\u00e7\u00e3o necess\u00e1rio em cada integra\u00e7\u00e3o espec\u00edfica. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O diagn\u00f3stico come\u00e7a ao longo do percurso efetivo: porta de entrada, fun\u00e7\u00e3o virtual ou representador, regra de switch, processamento de t\u00fanel ou de pol\u00edtica e carga de trabalho de destino. Se os contadores a montante e a jusante de uma etapa n\u00e3o corresponderem de forma plaus\u00edvel, isso constitui um motivo para verificar as correspond\u00eancias, as a\u00e7\u00f5es e o fallback. Uma funcionalidade ativada n\u00e3o substitui esta atribui\u00e7\u00e3o, uma vez que a capacidade do mapa n\u00e3o abrange todas as combina\u00e7\u00f5es de regras desejadas.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Os clusters heterog\u00e9neos tornam a compara\u00e7\u00e3o mais dif\u00edcil. No OpenShift 4.22, o descarregamento de hardware s\u00f3 ocorre se os pods e servi\u00e7os envolvidos estiverem atribu\u00eddos a n\u00f3s com SmartNIC compat\u00edvel. Se um caminho deste tipo encontrar um n\u00f3 normal, o seu processamento \u00e9 efetuado no kernel, o que limita a comunica\u00e7\u00e3o global. Por conseguinte, um \u00fanico n\u00f3 acelerado n\u00e3o ocupa um caminho de cluster totalmente acelerado. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Uma configura\u00e7\u00e3o inadequada do pod ou da rede tamb\u00e9m pode impedir o efeito esperado. A Red Hat salienta expressamente, relativamente \u00e0 funcionalidade do OpenShift 4.22, que o offload de hardware ativado, sem pods devidamente configurados, pode prejudicar o d\u00e9bito do pod. Por conseguinte, os operadores n\u00e3o devem resolver um desvio ativando mais op\u00e7\u00f5es, mas sim verificar primeiro a liga\u00e7\u00e3o da carga de trabalho, o modo de rede e os fluxos efetivamente alcan\u00e7ados. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A capacidade de regula\u00e7\u00e3o e os desvios de firmware pertencem \u00e0 mesma classe de erros: no caso de muitos clientes, liga\u00e7\u00f5es de curta dura\u00e7\u00e3o ou pol\u00edticas din\u00e2micas, o volume de fluxo relevante pode aumentar de forma diferente do esperado. Al\u00e9m disso, um controlador vinculado a uma vers\u00e3o espec\u00edfica ou um firmware diferente pode oferecer funcionalidades diferentes das previstas para a combina\u00e7\u00e3o de plataformas. Por isso, os dados de invent\u00e1rio e os contadores devem ser sempre arquivados juntamente com o conjunto de regras espec\u00edfico.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A <strong style=\"font-weight:700;color:inherit\">percurso de reca\u00edda controlado<\/strong> permite que o funcionamento seja pass\u00edvel de diagn\u00f3stico. Significa que o processamento por software se mant\u00e9m como alternativa prevista e que as altera\u00e7\u00f5es s\u00e3o implementadas gradualmente, com janelas de compara\u00e7\u00e3o e crit\u00e9rios de interrup\u00e7\u00e3o claros. O \u00abfallback\u00bb de software n\u00e3o constitui, por si s\u00f3, uma avaria, podendo ser o tratamento esperado para a\u00e7\u00f5es que o caminho de hardware selecionado n\u00e3o suporta na totalidade.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"entscheidungsrahmen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"entscheidungsrahmen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Tomar decis\u00f5es realistas em mat\u00e9ria de aquisi\u00e7\u00e3o e explora\u00e7\u00e3o<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Uma decis\u00e3o de aquisi\u00e7\u00e3o come\u00e7a pela carga de trabalho, n\u00e3o pela velocidade da porta ou pela designa\u00e7\u00e3o do produto. O uso de hardware especializado faz sentido nos casos em que se comprove que o processamento recorrente de pacotes consome tempo de CPU: por exemplo, numerosas redes virtuais, conjuntos de pol\u00edticas est\u00e1veis, tr\u00e1fego de overlay ou um percurso de encripta\u00e7\u00e3o definido. Na aus\u00eancia dessa comprova\u00e7\u00e3o, o ajuste da CPU e das filas ou uma placa de rede cl\u00e1ssica com descargas b\u00e1sicas adequadas podem ser a solu\u00e7\u00e3o mais simples.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Em seguida, \u00e9 necess\u00e1rio que o <strong style=\"font-weight:700;color:inherit\">Certificado de compatibilidade<\/strong> para a combina\u00e7\u00e3o espec\u00edfica: modelo de placa e modo de funcionamento, firmware, controladores, kernel, switch virtual ou CNI, bem como as fun\u00e7\u00f5es de correspond\u00eancia e a\u00e7\u00e3o necess\u00e1rias. Os aceleradores de infraestrutura program\u00e1veis podem, por exemplo, proporcionar o descarregamento de fluxos para fun\u00e7\u00f5es relacionadas com o estado ou com a sess\u00e3o; no entanto, isso n\u00e3o significa que todas as SmartNICs ou todas as plataformas ofere\u00e7am a mesma fun\u00e7\u00e3o. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A redu\u00e7\u00e3o esperada da carga da CPU s\u00f3 estar\u00e1 dispon\u00edvel como capacidade quando o processamento de pacotes tiver sido o gargalo e os n\u00facleos que ficaram livres puderem ser utilizados de forma adequada. Se forem, por exemplo, alocados para bases de dados, web workers ou reservas, trata-se de uma decis\u00e3o de arquitetura, n\u00e3o de um aumento autom\u00e1tico de desempenho. O restante equipamento do servidor continua, portanto, a ser determinante; a CPU, a mem\u00f3ria RAM e o armazenamento t\u00eam de ser adequados \u00e0 aplica\u00e7\u00e3o, tal como a rede. O artigo sobre <a href=\"https:\/\/webhosting.de\/pt\/alojamento-web-de-alto-desempenho-hardware-cpu-nvme-memoria-desempenho-servidor-turbo\/\">Hardware de servidor relevante para o desempenho na hospedagem web<\/a>.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No caso do IPsec, a verifica\u00e7\u00e3o \u00e9 particularmente espec\u00edfica: as variantes de offload documentadas v\u00e3o desde o offload de criptografia at\u00e9 \u00e0 externaliza\u00e7\u00e3o completa do encapsulamento, desencapsulamento, encripta\u00e7\u00e3o e prote\u00e7\u00e3o contra repeti\u00e7\u00e3o. A variante que pode ser utilizada depende do modelo, da gera\u00e7\u00e3o, do firmware e da configura\u00e7\u00e3o de criptografia. As notas espec\u00edficas do produto podem, al\u00e9m disso, incluir restri\u00e7\u00f5es para determinadas gera\u00e7\u00f5es ou larguras de banda; estas devem ser inclu\u00eddas na verifica\u00e7\u00e3o de aprova\u00e7\u00e3o antes da implementa\u00e7\u00e3o.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Uma DPU alarga a decis\u00e3o, criando uma \u00e1rea pr\u00f3pria de gest\u00e3o e confian\u00e7a. No modo BlueField-DPU, o sistema Arm integrado controla os recursos da NIC e o percurso dos dados, em vez de a placa funcionar apenas como adaptador do anfitri\u00e3o. Isto permite separar as tarefas de infraestrutura do anfitri\u00e3o, mas exige uma estrat\u00e9gia robusta em termos de direitos de acesso, imagens, atualiza\u00e7\u00f5es, monitoriza\u00e7\u00e3o e recupera\u00e7\u00e3o. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Do ponto de vista econ\u00f3mico, n\u00e3o \u00e9, portanto, apenas o pre\u00e7o da placa que conta. Em contrapartida, h\u00e1 de considerar a capacidade da CPU do host poupada ou evitada, a vida \u00fatil prevista da plataforma, bem como os custos adicionais com certifica\u00e7\u00e3o, pe\u00e7as de substitui\u00e7\u00e3o, manuten\u00e7\u00e3o do firmware e recupera\u00e7\u00e3o de incidentes. Uma SmartNIC faz sentido quando este c\u00e1lculo se baseia num percurso de dados reproduz\u00edvel e num ciclo de vida control\u00e1vel a longo prazo \u2014 e n\u00e3o porque o hardware especializado pare\u00e7a, por princ\u00edpio, mais r\u00e1pido.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Fontes e estado atual dos conhecimentos<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Estado da pesquisa: <time datetime=\"2026-10-24\">2026-10-24<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Data da pesquisa: 24 de outubro de 2026. As informa\u00e7\u00f5es relativas \u00e0s funcionalidades e \u00e0 compatibilidade dependem da vers\u00e3o, do modelo e da plataforma; antes do lan\u00e7amento, aplicam-se as matrizes respetivas do fabricante e da plataforma.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.kernel.org\/networking\/switchdev.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.openvswitch.org\/en\/latest\/howto\/dpdk\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/doca\/archive\/2-5-3\/nvidia%2Bbluefield%2Bdpu%2Bmodes%2Bof%2Boperation\/index.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.kernel.org\/6.16\/networking\/representors.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.redhat.com\/en\/documentation\/openshift_container_platform\/4.22\/html\/hardware_networks\/configuring-hardware-offloading<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/doca\/archive\/doca-v2.2.1\/ipsec-programming-guide\/index.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.amd.com\/r\/en-US\/ug1670-amd-pensando-ssdk-flow-offload-user-guide\/Introduction<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/networking\/display\/MLNXOFEDv23103220lts\/IPsec%2BFull%2BOffload<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.openvswitch.org\/en\/stable\/howto\/dpdk\/<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>Os SmartNICs podem transferir tarefas de rede recorrentes das CPUs dos anfitri\u00f5es. A vantagem desta abordagem depende do percurso real dos dados, das regras suportadas, da integra\u00e7\u00e3o na plataforma e do esfor\u00e7o operacional adicional.<\/p>","protected":false},"author":1,"featured_media":21964,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[922],"tags":[],"class_list":["post-21961","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technologie"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts\/21961","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/comments?post=21961"}],"version-history":[{"count":3,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts\/21961\/revisions"}],"predecessor-version":[{"id":21967,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts\/21961\/revisions\/21967"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/media\/21964"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/media?parent=21961"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/categories?post=21961"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/tags?post=21961"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}