{"id":21968,"date":"2026-11-03T11:10:00","date_gmt":"2026-11-03T10:10:00","guid":{"rendered":"https:\/\/webhosting.de\/?p=21968"},"modified":"2026-10-30T12:49:30","modified_gmt":"2026-10-30T11:49:30","slug":"planear-o-processamento-de-pacotes-dpdk-no-espaco-do-utilizador","status":"publish","type":"post","link":"https:\/\/webhosting.de\/pt\/dpdk-paketverarbeitung-userspace-planen\/","title":{"rendered":"DPDK: Planear corretamente o processamento de pacotes no espa\u00e7o do utilizador"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">A DPDK pode a <strong style=\"font-weight:700;color:inherit\">Processamento de pacotes no espa\u00e7o do utilizador<\/strong> acelerar quando taxas de pacotes elevadas ou lat\u00eancias constantes limitam o percurso normal da rede. Para tal, a aplica\u00e7\u00e3o consulta diretamente as filas da NIC e assume o planeamento dos n\u00facleos, da mem\u00f3ria, das filas e do acesso aos dispositivos. No entanto, isto n\u00e3o contorna quaisquer limites de hardware ou de seguran\u00e7a e aumenta consideravelmente o esfor\u00e7o operacional. Por isso, antes de iniciar uma opera\u00e7\u00e3o piloto, verifica o modelo exato da NIC e o PMD adequado, o planeamento de mem\u00f3ria e NUMA, a liga\u00e7\u00e3o necess\u00e1ria dos dispositivos, bem como um acesso de gest\u00e3o independente do caminho dos dados.   <\/p>\n<nav class=\"wh-toc\" aria-label=\"Conte\u00fado deste artigo\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">Ir diretamente para a sec\u00e7\u00e3o<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#dpdk-grundprinzip\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Princ\u00edpio fundamental do DPDK e classifica\u00e7\u00e3o correta<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#userspace-paketpfad\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Como funciona o caminho dos pacotes no espa\u00e7o do utilizador<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#architektur-und-grenzen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Arquitetura, recursos e limites r\u00edgidos<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#voraussetzungen-vor-dem-einsatz\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Verificar os pr\u00e9-requisitos antes da utiliza\u00e7\u00e3o do DPDK<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#dpdk-afxdp-kernelstack\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Comparar DPDK, AF_XDP e Kernelstack<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#queue-cpu-numa-planung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Planear de forma adequada as filas, o \u00abCPU-Pinning\u00bb e o NUMA<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#betrieb-und-beobachtbarkeit\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Monitorizar com seguran\u00e7a o DPDK durante o funcionamento<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#fehlerbilder-systematisch-pruefen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Verificar sistematicamente os erros t\u00edpicos<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#rollout-und-entscheidungsrahmen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Implementa\u00e7\u00e3o, manuten\u00e7\u00e3o de vers\u00f5es e decis\u00e3o de implementa\u00e7\u00e3o<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"dpdk-grundprinzip\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"dpdk-grundprinzip\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Princ\u00edpio fundamental do DPDK e classifica\u00e7\u00e3o correta<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><strong style=\"font-weight:700;color:inherit\">DPDK<\/strong> \u00e9 um framework para aplica\u00e7\u00f5es que precisam de processar pacotes de rede com o m\u00ednimo de sobrecarga poss\u00edvel no espa\u00e7o do utilizador. Em vez de utilizar o caminho habitual atrav\u00e9s da pilha de rede do kernel, dos sockets e das respetivas estruturas de pacotes, uma aplica\u00e7\u00e3o pode utilizar diretamente placas de rede selecionadas para o seu pr\u00f3prio caminho de dados. Isto visa, acima de tudo, elevadas taxas de pacotes, baixas lat\u00eancias e um processamento facilmente plane\u00e1vel no caso de muitos pacotes pequenos. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A express\u00e3o \u201esem limites do kernel\u201c \u00e9, neste contexto, uma forma abreviada. O kernel do Linux continua a estar presente para o sistema operativo, a gest\u00e3o da mem\u00f3ria, os processos, a seguran\u00e7a e in\u00fameras tarefas administrativas. O DPDK tamb\u00e9m n\u00e3o substitui os limites da placa de rede, nem os limites do PCIe, da largura de banda de mem\u00f3ria ou da CPU. No caso das interfaces ligadas, contorna sobretudo o percurso de dados habitual do kernel e transfere o processamento de pacotes para uma aplica\u00e7\u00e3o especializada. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No percurso de rede normal do Linux, os controladores de rede, o NAPI, a gest\u00e3o de pacotes e a camada de sockets funcionam em conjunto. Este percurso n\u00e3o \u00e9, de forma geral, puramente baseado em interrup\u00e7\u00f5es. Um DPDK-<strong style=\"font-weight:700;color:inherit\">Modo de sondagem do condutor<\/strong> consulta as filas de rece\u00e7\u00e3o diretamente a partir do espa\u00e7o do utilizador. A aplica\u00e7\u00e3o recebe pacotes em grupos, verifica-os ou altera-os e, em seguida, encaminha-os para uma fila de envio ou para uma etapa de processamento posterior. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">N\u00e3o se trata de um ajuste geral do kernel e, para uma aplica\u00e7\u00e3o Web comum com poucas liga\u00e7\u00f5es TCP, n\u00e3o \u00e9, na maioria das vezes, a primeira medida a tomar. S\u00f3 quando o pr\u00f3prio percurso dos pacotes de dados estiver comprovadamente limitado \u2014 por exemplo, no caso de distribui\u00e7\u00e3o de carga L4, filtragem ou pontos finais de t\u00fanel \u2014 \u00e9 que o ganho potencial justifica o esfor\u00e7o operacional adicional. As caracter\u00edsticas dependentes da vers\u00e3o devem ser verificadas em rela\u00e7\u00e3o \u00e0 documenta\u00e7\u00e3o da vers\u00e3o espec\u00edfica utilizada; uma vers\u00e3o candidata (Release Candidate) n\u00e3o \u00e9, neste contexto, equiparada a uma vers\u00e3o utilizada em produ\u00e7\u00e3o.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"userspace-paketpfad\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"userspace-paketpfad\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Como funciona o caminho dos pacotes no espa\u00e7o do utilizador<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Na entrada, a aplica\u00e7\u00e3o configura uma ou mais filas Rx da placa de rede. Um n\u00facleo de execu\u00e7\u00e3o atribu\u00eddo consulta uma fila num ciclo e recebe uma sequ\u00eancia de pacotes dispon\u00edveis. Estes <strong style=\"font-weight:700;color:inherit\">Processamento em rajada<\/strong> reduz o n\u00famero de chamadas de fun\u00e7\u00f5es e o esfor\u00e7o administrativo por pacote. Ap\u00f3s a classifica\u00e7\u00e3o, o reencaminhamento ou a altera\u00e7\u00e3o, a aplica\u00e7\u00e3o coloca os pacotes, em conjunto, numa fila de transmiss\u00e3o (Tx-Queue). <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O polling evita muitas altern\u00e2ncias de interrup\u00e7\u00e3o no caminho de dados com elevada carga e torna o trabalho de um n\u00facleo mais previs\u00edvel. O pre\u00e7o a pagar \u00e9 uma CPU constantemente ativa: mesmo com a fila vazia, o lcore continua a verificar se h\u00e1 novos pacotes. Por isso, este modelo adapta-se melhor a cargas constantemente elevadas do que a interfaces com tr\u00e1fego espor\u00e1dico ou muito vari\u00e1vel. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Os dados do pacote e os metadados encontram-se em <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">rte_mbuf<\/code>-objetos. Estes prov\u00eam de um mempool criado previamente e cont\u00eam, por exemplo, o comprimento do pacote, a porta de entrada, informa\u00e7\u00f5es de offload e, se for o caso, um hash RSS. Os pools reservados antecipadamente, uma atribui\u00e7\u00e3o fixa entre a fila e o n\u00facleo e percursos de processamento curtos promovem <strong style=\"font-weight:700;color:inherit\">Localiza\u00e7\u00e3o da cache<\/strong> e evitam estruturas de dados comuns desnecess\u00e1rias. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">No entanto, o Zero Copy n\u00e3o \u00e9 uma caracter\u00edstica autom\u00e1tica do DPDK. O facto de os dados serem ou n\u00e3o copiados, e em que ponto isso ocorre, depende da placa de rede (NIC), do controlador, das descargas e da l\u00f3gica da aplica\u00e7\u00e3o. Os frames grandes ou segmentados podem ser constitu\u00eddos por v\u00e1rios mbufs interligados; isto \u00e9 relevante, por exemplo, no caso dos frames jumbo. Quem reformular, aglutinar ou transferir dados de pacotes entre buffers incompat\u00edveis deve ter em conta poss\u00edveis movimenta\u00e7\u00f5es de mem\u00f3ria no seu pr\u00f3prio caminho de dados. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"architektur-und-grenzen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"architektur-und-grenzen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Arquitetura, recursos e limites r\u00edgidos<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A Camada de Abstra\u00e7\u00e3o do Ambiente, ou <strong style=\"font-weight:700;color:inherit\">EAL<\/strong>, inicializa o DPDK e disponibiliza, entre outras coisas, a reserva de mem\u00f3ria, o acesso a dispositivos, temporizadores e a atribui\u00e7\u00e3o de n\u00facleos l\u00f3gicos. Com base nisso, a aplica\u00e7\u00e3o configura filas Ethernet, mempools e o seu processamento. Um \u00ablcore\u00bb \u00e9, neste contexto, um n\u00facleo l\u00f3gico planeado para o DPDK, n\u00e3o apenas um thread de aplica\u00e7\u00e3o que se desloca aleatoriamente. Estas caracter\u00edsticas fundamentais do EAL est\u00e3o aqui comprovadas pela documenta\u00e7\u00e3o do DPDK 25.07; os detalhes espec\u00edficos da vers\u00e3o devem ser verificados adicionalmente para o \u00abrelease tag\u00bb utilizado. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para garantir um percurso de dados direto, \u00e9 frequente que um n\u00facleo processe um pacote na \u00edntegra: desde a rece\u00e7\u00e3o, passando pela decis\u00e3o, at\u00e9 ao envio. Este modelo \u00abrun-to-completion\u00bb evita transfer\u00eancias entre n\u00facleos. Por outro lado, um pipeline separa, por exemplo, o analisador, a pesquisa de fluxo e o reencaminhamento em etapas. Pode organizar as responsabilidades, mas acrescenta an\u00e9is, sincroniza\u00e7\u00e3o e, potencialmente, uma pior localiza\u00e7\u00e3o de mem\u00f3ria entre as etapas. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O planeamento deve tamb\u00e9m ter em conta a NUMA. A fila, o lcore e os conjuntos de pacotes devem, sempre que poss\u00edvel, estar localizados no mesmo n\u00f3 NUMA, para que o caminho dos dados n\u00e3o aceda regularmente \u00e0 mem\u00f3ria de outro soquete de CPU. Al\u00e9m disso, o desempenho alcan\u00e7\u00e1vel depende das funcionalidades da NIC, da liga\u00e7\u00e3o PCIe, da largura de banda da mem\u00f3ria, da frequ\u00eancia da CPU, do tamanho dos pacotes e da complexidade de cada decis\u00e3o relativa aos pacotes. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Um balanceador de carga L4 pode, com as informa\u00e7\u00f5es de IP e porta do DPDK, avaliar rapidamente, atribuir fluxos e reencaminhar pacotes. No entanto, a termina\u00e7\u00e3o TLS, os estados NAT complexos, o registo, as verifica\u00e7\u00f5es de integridade ou os back-ends lentos n\u00e3o ficam automaticamente mais r\u00e1pidos por causa disso. Da mesma forma, o plano de controlo necessita de tempo de CPU dispon\u00edvel para configura\u00e7\u00e3o, telemetria e tratamento de erros. Consequentemente, o DPDK acelera um percurso de dados claramente delimitado, mas n\u00e3o necessariamente todo o servi\u00e7o. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Tamb\u00e9m o tamanho e a dura\u00e7\u00e3o dos buffers de pacotes fazem parte da arquitetura. Os mempools limitam o n\u00famero de buffers dispon\u00edveis em simult\u00e2neo, enquanto a aplica\u00e7\u00e3o tem de gerir corretamente as mudan\u00e7as de propriedade. Os pools com dimens\u00f5es demasiado reduzidas podem esgotar-se sob carga; as reservas excessivas ocupam mem\u00f3ria. O tamanho adequado resulta das filas de espera, dos tamanhos de picos de tr\u00e1fego, do percurso dos pacotes e dos picos de carga esperados, e n\u00e3o de uma regra universal. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"voraussetzungen-vor-dem-einsatz\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"voraussetzungen-vor-dem-einsatz\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Verificar os pr\u00e9-requisitos antes da utiliza\u00e7\u00e3o do DPDK<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O DPDK s\u00f3 se torna planific\u00e1vel quando o hardware, a mem\u00f3ria e a atribui\u00e7\u00e3o da CPU est\u00e3o em sintonia. Uma instala\u00e7\u00e3o, por si s\u00f3, n\u00e3o cria um caminho de dados eficiente: o PMD tem de ser compat\u00edvel com o modelo espec\u00edfico da NIC e os recursos t\u00eam de poder ser reservados para a aplica\u00e7\u00e3o. A verifica\u00e7\u00e3o seguinte distingue os requisitos t\u00e9cnicos m\u00ednimos das suposi\u00e7\u00f5es que s\u00f3 se aplicam ao dispositivo efetivamente utilizado. <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-nic-speicherplanung-voraussetzungen-96cb18a6-detail1-1c84946f1c-1024x683.webp\" class=\"wp-image-21990\" alt=\"Grande plano de uma placa de rede num servidor aberto, como s\u00edmbolo do planeamento de recursos e de mem\u00f3ria.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-nic-speicherplanung-voraussetzungen-96cb18a6-detail1-1c84946f1c-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-nic-speicherplanung-voraussetzungen-96cb18a6-detail1-1c84946f1c-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-nic-speicherplanung-voraussetzungen-96cb18a6-detail1-1c84946f1c-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-nic-speicherplanung-voraussetzungen-96cb18a6-detail1-1c84946f1c-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-nic-speicherplanung-voraussetzungen-96cb18a6-detail1-1c84946f1c.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Imagem ilustrativa gerada por IA: o NIC, os recursos do servidor e o planeamento da mem\u00f3ria t\u00eam de estar em sintonia antes de um caminho DPDK.<\/figcaption><\/figure><div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Pontos a verificar antes da utiliza\u00e7\u00e3o de um caminho de dados DPDK\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Pontos a verificar antes da utiliza\u00e7\u00e3o de um caminho de dados DPDK<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Pr\u00e9-requisito<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Significado<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Quest\u00e3o concreta a analisar<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">NIC e PMD<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Um PMD disponibiliza o acesso DPDK \u00e0 placa de rede; as funcionalidades dependem do modelo e do controlador.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O modelo exato da placa de rede (NIC) consta da lista de controladores suportados e as funcionalidades necess\u00e1rias est\u00e3o documentadas?<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Planeamento da mem\u00f3ria e Hugepages<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">As Hugepages s\u00e3o o modo de funcionamento normal e eficiente para grandes conjuntos de pacotes; o DPDK disp\u00f5e tamb\u00e9m de um modo especial, com a op\u00e7\u00e3o \u2013no-huge, que tem os seus pr\u00f3prios limites de adequa\u00e7\u00e3o e de controlador.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Foram reservadas Hugepages suficientes para o caminho de dados previsto, ou a utiliza\u00e7\u00e3o sem Hugepages foi deliberadamente avaliada e justificada?<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">IOMMU e VFIO<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">No caso de muitos PMDs, os dispositivos s\u00e3o separados do controlador normal do kernel e disponibilizados atrav\u00e9s do VFIO; os PMDs bifurcados seguem um modelo diferente.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Que m\u00e9todo de liga\u00e7\u00e3o exige o PMD em quest\u00e3o e a configura\u00e7\u00e3o IOMMU prevista est\u00e1 dispon\u00edvel no VFIO?<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Fixa\u00e7\u00e3o da CPU<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Os n\u00facleos dedicados evitam a concorr\u00eancia entre os agendadores no caminho de dados de sondagem.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Que n\u00facleos l\u00f3gicos est\u00e3o reservados para os lcores, sem ocupar os servi\u00e7os do sistema?<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">NUMA<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O acesso \u00e0 mem\u00f3ria local reduz os acessos desnecess\u00e1rios entre n\u00f3s NUMA.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O NIC, o lcores e os mempools est\u00e3o no mesmo n\u00f3 NUMA?<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Planeamento de filas<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">As filas Rx e Tx determinam a forma como o trabalho \u00e9 distribu\u00eddo pelos n\u00facleos.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Existe uma atribui\u00e7\u00e3o \u00fanica de fila por caminho de dados, sem partilha desnecess\u00e1ria?<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Monitoriza\u00e7\u00e3o<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">As perdas de encomendas e os estrangulamentos de recursos t\u00eam de continuar a ser vis\u00edveis durante o funcionamento.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Que contadores relativos \u00e0 NIC, \u00e0s filas, aos conjuntos e \u00e0 aplica\u00e7\u00e3o s\u00e3o monitorizados?<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">As Hugepages s\u00e3o a abordagem habitual para conjuntos de pacotes de grande dimens\u00e3o, mas n\u00e3o constituem uma condi\u00e7\u00e3o obrigat\u00f3ria para todas as aplica\u00e7\u00f5es DPDK. O EAL tamb\u00e9m suporta a op\u00e7\u00e3o \u2013no-huge. Este modo especial n\u00e3o constitui uma recomenda\u00e7\u00e3o padr\u00e3o equivalente: a adequa\u00e7\u00e3o, a gest\u00e3o da mem\u00f3ria e os limites dos controladores devem ser verificados antes da fase piloto. Os princ\u00edpios b\u00e1sicos do sistema e do EAL aqui utilizados est\u00e3o documentados na vers\u00e3o DPDK 25.07; verifique tamb\u00e9m se as op\u00e7\u00f5es correspondem \u00e0 vers\u00e3o efetivamente instalada.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Particularmente cr\u00edtica \u00e9 a <strong style=\"font-weight:700;color:inherit\">Vincula\u00e7\u00e3o de dispositivos<\/strong>. Muitos PMDs exigem que a NIC em quest\u00e3o seja desligada do controlador normal do kernel e, por exemplo, ligada a <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">vfio-pci<\/code> \u00e9 associada. A interface deixa ent\u00e3o de estar regularmente dispon\u00edvel para a pilha de rede normal do Linux. No entanto, o procedimento concreto deve ser adequado ao PMD e n\u00e3o pode ser aplicado de forma generalizada a todas as placas de rede suportadas. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Os PMDs bifurcados constituem uma exce\u00e7\u00e3o importante. A documenta\u00e7\u00e3o do controlador indica que esses PMDs n\u00e3o devem ser desligados do controlador do kernel correspondente. Nesse caso, o controlador do kernel pode permanecer ligado enquanto um caminho de dados do espa\u00e7o do utilizador utiliza determinados recursos. A documenta\u00e7\u00e3o sem vers\u00e3o, cujo link se encontra acima, reflete o estado de desenvolvimento 26.11.0-rc1 e n\u00e3o constitui um guia espec\u00edfico para a vers\u00e3o 26.07. Verifique o suporte a dispositivos e as ferramentas do kernel dispon\u00edveis no manual do PMD concretamente utilizado. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Antes de qualquer altera\u00e7\u00e3o, a consulta de estado seguinte fornece um invent\u00e1rio dos dispositivos PCI e da sua associa\u00e7\u00e3o atual aos controladores. Ela pr\u00f3pria n\u00e3o altera nenhuma associa\u00e7\u00e3o. Execute-a no sistema de destino utilizando o caminho correspondente \u00e0 estrutura de c\u00f3digo-fonte ou de ferramentas do DPDK instalada. <\/p>\n<div class=\"wh-code-window\" data-wh-code style=\"margin:28px 0 34px;border:1px solid #2c4656;border-radius:12px;overflow:hidden;background:#132a3b;box-shadow:0 9px 25px -13px rgba(15,35,55,.2)\"><div class=\"wh-code-toolbar\" style=\"display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:10px;padding:11px 16px;background:#223e50;color:#edf5fa;font-size:13px;line-height:1.5;font-weight:600\"><span>C\u00f3digo<\/span><button type=\"button\" class=\"wh-code-copy\" data-wh-copy hidden style=\"padding:6px 11px;border:1px solid #7893a1;border-radius:6px;background:transparent;color:#fff;font-size:12px;line-height:1.5;font-weight:600;cursor:pointer\">Copiar c\u00f3digo<\/button><span class=\"wh-copy-status\" aria-live=\"polite\"><\/span><span data-wh-copy-success hidden>Copiado<\/span><span data-wh-copy-fallback hidden>C\u00f3digo destacado \u2013 por favor, copie<\/span><\/div><pre class=\"wh-code\" data-no-translation translate=\"no\" style=\"display:block;margin:0;padding:20px;max-width:100%;overflow-x:auto;color:#edf5fa;background:#132a3b;font:14px\/1.75 ui-monospace,SFMono-Regular,Menlo,Consolas,monospace;white-space:pre;direction:ltr;text-align:left\"><code class=\"language-text\" style=\"font:inherit;color:inherit;background:transparent;padding:0;border:0;white-space:inherit\">.\/usertools\/dpdk-devbind.py --status<\/code><\/pre><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O acesso \u00e0 gest\u00e3o do Plane e o caminho dos dados produtivos devem ser separados, mesmo que o PMD selecionado n\u00e3o substitua o controlador do kernel. A acessibilidade via SSH ou consola n\u00e3o deve depender de uma interface cuja liga\u00e7\u00e3o ou distribui\u00e7\u00e3o de tr\u00e1fego seja alterada durante a opera\u00e7\u00e3o piloto. Uma interface de gest\u00e3o separada, um acesso fora de banda ou um caminho de recupera\u00e7\u00e3o local previamente testado limitam o risco de uma configura\u00e7\u00e3o incorreta.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"dpdk-afxdp-kernelstack\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"dpdk-afxdp-kernelstack\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Comparar DPDK, AF_XDP e Kernelstack<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A escolha do caminho de dados n\u00e3o \u00e9 uma classifica\u00e7\u00e3o, mas sim uma decis\u00e3o operacional. A pilha do kernel do Linux, o AF_XDP e o DPDK alteram, cada um \u00e0 sua maneira, o esfor\u00e7o, o acesso aos dispositivos e o consumo da CPU. A op\u00e7\u00e3o adequada depende de saber se \u00e9 efetivamente a taxa de pacotes ou a lat\u00eancia no caminho de rede que constitui o limite \u2014 ou se s\u00e3o a aplica\u00e7\u00e3o, a encripta\u00e7\u00e3o e os back-ends que constituem o gargalo.<\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Classifica\u00e7\u00e3o do Kernelstack, do AF_XDP e do DPDK\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Classifica\u00e7\u00e3o do Kernelstack, do AF_XDP e do DPDK<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Abordagem<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Percurso dos dados<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Posse de equipamentos<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Comportamento da CPU<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Aplica\u00e7\u00f5es t\u00edpicas<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Fronteira mais importante<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Pilha do kernel do Linux<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Pilha de rede padr\u00e3o do kernel com sockets e fun\u00e7\u00f5es do kernel.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">A NIC continua a ser a interface padr\u00e3o do kernel.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Interrup\u00e7\u00f5es para notifica\u00e7\u00e3o de eventos; sob carga, utiliza-se o NAPI-Polling; o processamento e as aplica\u00e7\u00f5es est\u00e3o sujeitos ao controlo do kernel\/agendador.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Servi\u00e7os gerais de servidor, encaminhamento e aplica\u00e7\u00f5es com ferramentas Linux existentes.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O processamento de pacotes pode tornar-se um gargalo quando a taxa de pacotes \u00e9 muito elevada.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">AF_XDP<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">XDP com sockets do espa\u00e7o do utilizador; modo \u00abCopy\u00bb ou \u00abZero-Copy\u00bb, dependendo do controlador.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">A integra\u00e7\u00e3o continua a basear-se nos modelos XDP e Socket.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Depende do modo, do controlador e da atribui\u00e7\u00e3o da fila.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Acelera\u00e7\u00e3o seletiva de filas espec\u00edficas com recurso adicional ao kernel.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">A funcionalidade Zero Copy n\u00e3o est\u00e1 dispon\u00edvel em todos os controladores.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">DPDK<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Os PMDs processam os descritores Rx e Tx diretamente no espa\u00e7o do utilizador.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Muitos PMDs exigem uma liga\u00e7\u00e3o fora do caminho de rede normal do kernel; os PMDs bifurcados, por outro lado, mant\u00eam o controlador do kernel ligado.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O polling consome n\u00facleos reservados mesmo com pouca carga.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Elevadas taxas de pacotes, filtros especializados, equilibradores de carga e NFV.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Maior planeamento de recursos; a integra\u00e7\u00e3o do n\u00facleo e a distribui\u00e7\u00e3o do tr\u00e1fego dependem do modelo PMD espec\u00edfico.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O AF_XDP \u00e9 uma op\u00e7\u00e3o interm\u00e9dia para equipas que pretendem processar pacotes antecipadamente, mantendo-se, no entanto, pr\u00f3ximas do modelo de rede do Linux. O kernel descreve um modo de c\u00f3pia, bem como o Zero Copy, que requer suporte do controlador. Se o Zero Copy for explicitamente solicitado, a cria\u00e7\u00e3o do socket pode falhar caso o controlador n\u00e3o ofere\u00e7a essa capacidade.  Para compreender melhor a camada XDP, consulte o artigo <a href=\"https:\/\/webhosting.de\/pt\/xdp-processamento-de-pacotes-de-alto-desempenho-velocidade-do-kernel\/\">XDP e eXpress Data Path<\/a>.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O DPDK, por outro lado, utiliza \u00abPoll Mode Drivers\u00bb e processa as filas diretamente a partir da aplica\u00e7\u00e3o. Isto permite contornar as partes relacionadas com sockets e interrup\u00e7\u00f5es no percurso de dados do DPDK, mas exige a gest\u00e3o da mem\u00f3ria, das filas e da aloca\u00e7\u00e3o de n\u00facleos. <strong style=\"font-weight:700;color:inherit\">Zero Copy<\/strong> Isto n\u00e3o constitui nem uma promessa geral de desempenho nem uma caracter\u00edstica autom\u00e1tica de qualquer caminho DPDK; as c\u00f3pias dependem da aplica\u00e7\u00e3o, das transfer\u00eancias de carga e das transfer\u00eancias de mem\u00f3ria. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Escolha a pilha do kernel se o encaminhamento, a firewall, a observabilidade e a facilidade de opera\u00e7\u00e3o forem mais importantes do que um percurso de pacotes especializado. Considere o AF_XDP em casos de acelera\u00e7\u00e3o direcionada com liga\u00e7\u00e3o ao kernel. O DPDK s\u00f3 se justifica quando existe uma necessidade comprovada de elevada taxa de pacotes ou lat\u00eancia constante, suporte existente para a placa de rede (NIC) e uma equipa capaz de assumir de forma permanente a responsabilidade operacional adicional.<\/p>\n<aside class=\"wh-callout\" style=\"display:block;margin:28px 0;padding:20px 23px;border:1px solid #d1e4dd;border-left:4px solid #187065;border-radius:11px;background:#f0f7f4\"><p class=\"wh-callout-title\" style=\"margin:0 0 8px;color:#1c5c53;font-size:16px;font-weight:700;line-height:1.5\">A escolha n\u00e3o deve basear-se apenas no rendimento<\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Avalie em conjunto o tamanho dos pacotes, a taxa de pacotes, o objetivo de lat\u00eancia, as funcionalidades de protocolo necess\u00e1rias, as ferramentas operacionais existentes e os recursos humanos necess\u00e1rios. Um percurso de pacotes mais r\u00e1pido n\u00e3o resolve um estrangulamento no processamento TLS, na base de dados ou no servi\u00e7o de backend.<\/p>\n<\/aside><\/section><section class=\"wh-section\" aria-labelledby=\"queue-cpu-numa-planung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"queue-cpu-numa-planung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Planear de forma adequada as filas, o \u00abCPU-Pinning\u00bb e o NUMA<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Uma resistente <strong style=\"font-weight:700;color:inherit\">Atribui\u00e7\u00e3o de filas<\/strong> Come\u00e7a pela proximidade entre a NIC, a CPU e a mem\u00f3ria. O EAL suporta a sele\u00e7\u00e3o de n\u00facleos l\u00f3gicos, a reserva de mem\u00f3ria e a aloca\u00e7\u00e3o de dispositivos. Para um percurso de dados simples, faz geralmente sentido atribuir de forma fixa uma fila Rx a um lcore, criar o mempool correspondente no n\u00f3 NUMA local e, em seguida, transferir o processamento para uma fila Tx adequada. Estas especifica\u00e7\u00f5es b\u00e1sicas do EAL est\u00e3o documentadas na documenta\u00e7\u00e3o do DPDK 25.07 e devem ser verificadas em rela\u00e7\u00e3o \u00e0 data de lan\u00e7amento utilizada, no caso de op\u00e7\u00f5es dependentes da vers\u00e3o. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Um exemplo n\u00e3o espec\u00edfico de um produto para um anfitri\u00e3o com dois n\u00f3s NUMA seria o seguinte: a placa de rede (NIC) no n\u00f3 0 recebe duas filas de rece\u00e7\u00e3o (Rx); cada lcore no n\u00f3 0 processa uma fila na \u00edntegra. Os buffers de pacotes tamb\u00e9m se encontram no n\u00f3 0. Um outro n\u00facleo, que n\u00e3o realiza sondagens, fica dispon\u00edvel para tarefas administrativas, enquanto o n\u00f3 1 \u00e9 destinado a outros servi\u00e7os ou a percursos de dados claramente separados.<\/p>\n<ul class=\"wh-list\" role=\"list\" style=\"list-style:none;margin:24px 0;padding:0\"><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Percurso de dados: um lcore atribu\u00eddo de forma fixa a cada fila, pools de mem\u00f3ria locais e pares Rx\/Tx claramente identificados.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Gest\u00e3o: reservar capacidade da CPU para telemetria, l\u00f3gica de controlo, eventos e servi\u00e7os do sistema operativo.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Reserva: prever capacidade para picos de carga, resolu\u00e7\u00e3o de problemas e expans\u00f5es planeadas, em vez de alocar todos os n\u00facleos de forma permanente.<\/li><\/ul><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">N\u00e3o partilhe uma fila Rx entre v\u00e1rios lcores. O guia PMD desaconselha a divis\u00e3o de filas Rx e Tx, uma vez que os bloqueios globais necess\u00e1rios para tal podem comprometer significativamente o desempenho. O acesso simult\u00e2neo de v\u00e1rios lcores a uma fila Tx s\u00f3 est\u00e1 previsto como exce\u00e7\u00e3o documentada se o controlador tiver a capacidade de <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">RTE_ETH_TX_OFFLOAD_MT_LOCKFREE<\/code> indica. Verifique esta capacidade para a combina\u00e7\u00e3o espec\u00edfica de NIC\/PMD; n\u00e3o a deduza nem a partir da velocidade da porta nem de um interruptor geral de descarregamento. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Um pipeline com etapas separadas de an\u00e1lise, classifica\u00e7\u00e3o e envio pode tornar as responsabilidades mais claras. A abordagem de pipeline documentada transfere pacotes para outros n\u00facleos atrav\u00e9s de an\u00e9is; isto resulta em acessos adicionais \u00e0 mem\u00f3ria e transfer\u00eancias. Para filtros simples ou encaminhamento L4, o \u00abrun-to-completion\u00bb por fila \u00e9 frequentemente mais f\u00e1cil de planear. S\u00f3 se devem utilizar v\u00e1rias etapas se a divis\u00e3o de tarefas justificar o esfor\u00e7o adicional no perfil de carga espec\u00edfico. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Tamb\u00e9m <strong style=\"font-weight:700;color:inherit\">Transfer\u00eancias para o hardware<\/strong> n\u00e3o devem ser tidas em conta no planeamento. As fun\u00e7\u00f5es de soma de verifica\u00e7\u00e3o, segmenta\u00e7\u00e3o, RSS ou fluxo dispon\u00edveis dependem das capacidades do dispositivo Ethernet espec\u00edfico e do seu PMD. Verifica-as antes da conce\u00e7\u00e3o e trata a aus\u00eancia de descarregamento como um caso normal de planeamento, e n\u00e3o como uma exce\u00e7\u00e3o.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"betrieb-und-beobachtbarkeit\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"betrieb-und-beobachtbarkeit\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Monitorizar com seguran\u00e7a o DPDK durante o funcionamento<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O funcionamento de um caminho de dados DPDK requer m\u00e9tricas que analisem em conjunto o processamento de pacotes e os recursos. Registe, no m\u00ednimo, os pacotes processados, rejeitados e com erros, bem como valores espec\u00edficos da aplica\u00e7\u00e3o relativos \u00e0s taxas de processamento, reservas do mempool e <strong style=\"font-weight:700;color:inherit\">Distribui\u00e7\u00e3o da lat\u00eancia<\/strong> em vez de apenas um valor m\u00e9dio. Os contadores adicionais de portas, filas ou controladores dispon\u00edveis dependem do PMD espec\u00edfico, da NIC e da aplica\u00e7\u00e3o, devendo ser verificados para a combina\u00e7\u00e3o utilizada. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">O polling constitui um conflito de objetivos deliberado. Um lcore consulta continuamente a sua fila Rx para que os pacotes possam ser processados sem recorrer ao caminho normal de interrup\u00e7\u00e3o. Mesmo com pouco ou nenhum tr\u00e1fego, o ciclo de polling permanece, no entanto, ativo. Por isso, al\u00e9m dos lcores do caminho de dados, reserve capacidade de CPU para a l\u00f3gica de controlo, a telemetria e o sistema operativo. A documenta\u00e7\u00e3o EAL utilizada como complemento refere-se ao DPDK 25.07; as funcionalidades dependentes da vers\u00e3o devem ser verificadas na vers\u00e3o instalada.  <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-monitoring-queue-cpu-96cb18a6-detail2-a9bc2ce1c3-1024x683.webp\" class=\"wp-image-21991\" alt=\"O administrador consulta, numa esta\u00e7\u00e3o de trabalho, m\u00e9tricas relativas \u00e0 an\u00e1lise de filas, da CPU e da perda de pacotes.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-monitoring-queue-cpu-96cb18a6-detail2-a9bc2ce1c3-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-monitoring-queue-cpu-96cb18a6-detail2-a9bc2ce1c3-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-monitoring-queue-cpu-96cb18a6-detail2-a9bc2ce1c3-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-monitoring-queue-cpu-96cb18a6-detail2-a9bc2ce1c3-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/dpdk-monitoring-queue-cpu-96cb18a6-detail2-a9bc2ce1c3.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">Imagem ilustrativa gerada por IA: Para o funcionamento, s\u00e3o avaliados em conjunto os contadores de filas, a carga da CPU e as perdas de pacotes.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Para a an\u00e1lise das causas, \u00e9 importante a correla\u00e7\u00e3o temporal. Se a perda de pacotes ocorrer em simult\u00e2neo com contadores de erros, reservas do mempool em decl\u00ednio ou um caminho de dados lcore sobrecarregado, estas s\u00e3o, numa primeira fase, pistas que podem ser verificadas, mas ainda n\u00e3o constituem uma prova inequ\u00edvoca da causa. Os tempos de resposta vari\u00e1veis podem estar relacionados, entre outros fatores, com mem\u00f3ria distante do NUMA, tarefas concorrentes ou transfer\u00eancias de pipeline. Compare essas hip\u00f3teses, respetivamente, com a atribui\u00e7\u00e3o de n\u00facleos, a distribui\u00e7\u00e3o de filas e os valores medidos no mesmo intervalo de tempo.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A captura r\u00e1pida na interface n\u00e3o \u00e9 sin\u00f3nimo de registo completo e sem perdas de pacotes a longo prazo. Para estat\u00edsticas de fluxo ou an\u00e1lise de cabe\u00e7alhos, podem ser suficientes poucos metadados. Se for necess\u00e1rio guardar todos os pacotes, a largura de banda de armazenamento, o volume do buffer, a taxa de transfer\u00eancia de escrita e o suporte de armazenamento escolhido limitam adicionalmente a configura\u00e7\u00e3o. A prote\u00e7\u00e3o de dados e as regras de conserva\u00e7\u00e3o s\u00e3o requisitos independentes que a taxa de transfer\u00eancia da rede n\u00e3o resolve.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Planeia as m\u00e1quinas virtuais e os contentores como uma tarefa de integra\u00e7\u00e3o espec\u00edfica. Verifica, para a plataforma em quest\u00e3o, como s\u00e3o disponibilizados o acesso aos dispositivos, a mem\u00f3ria, a atribui\u00e7\u00e3o da CPU e os direitos necess\u00e1rios. Verifique esta combina\u00e7\u00e3o com o PMD utilizado, em vez de adotar par\u00e2metros de exemplo de forma gen\u00e9rica. O guia do Linux cujo link se encontra aqui est\u00e1 atualmente na vers\u00e3o de desenvolvimento 26.11.0-rc1; para uma instala\u00e7\u00e3o em produ\u00e7\u00e3o, \u00e9 determinante a documenta\u00e7\u00e3o da vers\u00e3o efetivamente instalada. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"fehlerbilder-systematisch-pruefen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"fehlerbilder-systematisch-pruefen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Verificar sistematicamente os erros t\u00edpicos<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A dete\u00e7\u00e3o de erros deve, em primeiro lugar, distinguir os sintomas observ\u00e1veis das poss\u00edveis causas. N\u00e3o altere simultaneamente a liga\u00e7\u00e3o do controlador, o n\u00famero da fila e os par\u00e2metros de mem\u00f3ria, pois, nesse caso, j\u00e1 n\u00e3o ser\u00e1 poss\u00edvel identificar o fator desencadeante. Contadores n\u00e3o destrutivos, informa\u00e7\u00f5es sobre a configura\u00e7\u00e3o e uma compara\u00e7\u00e3o entre a fila afetada e a n\u00e3o afetada fornecem, na maioria das vezes, as pistas mais fi\u00e1veis antes de se proceder a qualquer interven\u00e7\u00e3o.<\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Erros t\u00edpicos do DPDK e testes iniciais n\u00e3o invasivos\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Erros t\u00edpicos do DPDK e testes iniciais n\u00e3o invasivos<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Sintoma<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Hip\u00f3teses a testar<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Inspec\u00e7\u00e3o n\u00e3o destrutiva<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">perdas de pacotes<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O lcore de processamento pode n\u00e3o estar a acompanhar o ritmo, os buffers de pacotes podem estar a esgotar-se ou o PMD pode estar a reportar erros de rece\u00e7\u00e3o.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Comparar os contadores de aplica\u00e7\u00f5es, portas e controladores dispon\u00edveis, as reservas do mempool e a utiliza\u00e7\u00e3o da CPU no mesmo intervalo de tempo.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Lat\u00eancia irregular<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Podem estar envolvidos mem\u00f3rias fora do NUMA, tarefas concorrentes ou transfer\u00eancias adicionais na pipeline.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Verificar a aloca\u00e7\u00e3o da CPU e da mem\u00f3ria, bem como o propriet\u00e1rio da fila; registar os picos de lat\u00eancia separadamente por caminho de dados.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Elevada carga da CPU com pouco tr\u00e1fego<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O ciclo de sondagem continua mesmo quando a fila de rece\u00e7\u00e3o est\u00e1 vazia.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Comparar a utiliza\u00e7\u00e3o do n\u00facleo \u00abpollending\u00bb com a taxa de pacotes real e registar os n\u00facleos reservados.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Servidor indispon\u00edvel<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Uma interface de gest\u00e3o pode ter sido reconfigurada ou a sua rota de tr\u00e1fego pode ter sido alterada.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Verificar o estado dos dispositivos PCI e o estado da liga\u00e7\u00e3o atrav\u00e9s de um acesso de gest\u00e3o ou de consola independente.<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Falta o \u00aboffload\u00bb<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">O modelo NIC, o PMD ou a configura\u00e7\u00e3o podem n\u00e3o proporcionar a capacidade pretendida.<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Comparar a matriz de funcionalidades com as capacidades do dispositivo indicadas para o modelo espec\u00edfico da placa de rede.<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Se o comportamento da fila for an\u00f3malo, verifica o propriet\u00e1rio da fila e o n\u00f3 NUMA do mempool. No modelo \u00abrun-to-completion\u00bb, o lcore atribu\u00eddo processa a rece\u00e7\u00e3o, o processamento e o envio; um pipeline transfere os pacotes para outros n\u00facleos. No entanto, n\u00e3o dividas a fila de rece\u00e7\u00e3o (Rx) entre lcores. O acesso simult\u00e2neo a uma fila de transmiss\u00e3o (Tx) s\u00f3 \u00e9 permitido se tiver sido notificado <code data-no-translation style=\"font:600 .87em\/1.5 ui-monospace,monospace;color:#235063;background:#edf3f5;border-radius:4px;padding:.1em .3em\">RTE_ETH_TX_OFFLOAD_MT_LOCKFREE<\/code>-Esta funcionalidade est\u00e1 prevista como uma exce\u00e7\u00e3o. Um bloqueio autoaplic\u00e1vel faz com que a partilha de filas n\u00e3o seja a estrat\u00e9gia de escalabilidade recomendada. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Na aus\u00eancia de offloads de hardware, a quest\u00e3o correta n\u00e3o \u00e9 apenas saber qual a op\u00e7\u00e3o que foi ativada, mas sim quais as capacidades que o dispositivo e o PMD disponibilizam efetivamente. Uma aplica\u00e7\u00e3o pode planear uma fun\u00e7\u00e3o pretendida, mesmo que esta n\u00e3o esteja dispon\u00edvel para esse modelo. Compara o suporte para a NIC espec\u00edfica com as capacidades comunicadas em tempo de execu\u00e7\u00e3o, antes de condicionar o percurso de dados a essa descarga.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Os resultados do testpmd devem ser considerados como uma linha de base ou um teste funcional, e n\u00e3o como uma prova de desempenho da aplica\u00e7\u00e3o posterior. No modo de encaminhamento de E\/S, os pacotes s\u00e3o encaminhados sem altera\u00e7\u00f5es, sem que o seu conte\u00fado seja analisado para processamento t\u00e9cnico. Este modo n\u00e3o reproduz analisadores, tabelas de fluxo, NAT, encripta\u00e7\u00e3o nem o estado do protocolo. A documenta\u00e7\u00e3o sem vers\u00e3o, cujo link se encontra aqui, refere-se \u00e0 vers\u00e3o 26.11.0-rc1; verifique o comportamento no manual da vers\u00e3o instalada. Registe o modo de encaminhamento, o tamanho dos pacotes, o n\u00famero de filas Rx\/Tx e os n\u00facleos de encaminhamento e repita a compara\u00e7\u00e3o com a l\u00f3gica de processamento real. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"rollout-und-entscheidungsrahmen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"rollout-und-entscheidungsrahmen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Implementa\u00e7\u00e3o, manuten\u00e7\u00e3o de vers\u00f5es e decis\u00e3o de implementa\u00e7\u00e3o<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Come\u00e7a por um teste isolado e um <strong style=\"font-weight:700;color:inherit\">perfil de carga<\/strong>: tamanhos dos pacotes, carga de pico, n\u00famero de fluxos e etapas de processamento necess\u00e1rias. Verifica a NIC espec\u00edfica, incluindo o controlador de modo de sondagem adequado e as fun\u00e7\u00f5es necess\u00e1rias, com base na vis\u00e3o geral oficial do hardware e na matriz de controladores. O facto de um fabricante constar da lista n\u00e3o confirma, por si s\u00f3, nem todas as placas nem todas as descargas. Em seguida, testa com l\u00f3gica de aplica\u00e7\u00e3o real, e n\u00e3o exclusivamente com um exemplo de reencaminhamento. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Regista a vers\u00e3o do DPDK, o firmware, os controladores, o kernel e a configura\u00e7\u00e3o para cada teste. Antes de efetuar uma atualiza\u00e7\u00e3o, leia as notas de lan\u00e7amento da vers\u00e3o espec\u00edfica prevista e documente quais as altera\u00e7\u00f5es relevantes para o seu pr\u00f3prio percurso de dados. As notas de lan\u00e7amento de vers\u00f5es diferentes n\u00e3o substituem esta correspond\u00eancia, uma vez que as funcionalidades e restri\u00e7\u00f5es podem variar entre vers\u00f5es. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Um ponto espec\u00edfico a ter em conta nas Notas de Lan\u00e7amento do DPDK 26.07 \u00e9 a altera\u00e7\u00e3o do algoritmo de limpeza\/reabastecimento da cache do mempool: o seu tamanho efetivo corresponde agora ao tamanho configurado; anteriormente, era 50 por cento maior. Apenas quando cada lcore de um mempool retira exclusivamente objetos ou devolve exclusivamente objetos \u00e9 que as Notas de Lan\u00e7amento recomendam duplicar o tamanho configurado da cache, para evitar uma poss\u00edvel duplica\u00e7\u00e3o da taxa de falhas de cache. Isto aplica-se, por exemplo, a pipelines com lcores Rx e Tx separados, e n\u00e3o de forma generalizada ao modo \u00abrun-to-completion\u00bb. A altera\u00e7\u00e3o diz respeito \u00e0 vers\u00e3o 26.07; a p\u00e1gina hist\u00f3rica da vers\u00e3o referida encontra-se agora na documenta\u00e7\u00e3o relativa \u00e0 vers\u00e3o 26.11.0-rc1. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Comece com um projeto-piloto de \u00e2mbito limitado e crit\u00e9rios de interrup\u00e7\u00e3o bem definidos. Compare o d\u00e9bito, os percentis de lat\u00eancia elevada, as perdas de pacotes e os requisitos de CPU em condi\u00e7\u00f5es id\u00eanticas \u00e0s da opera\u00e7\u00e3o atual. Verifique a monitoriza\u00e7\u00e3o, os rein\u00edcios e o regresso \u00e0 configura\u00e7\u00e3o anterior. Tenha em conta os custos operacionais; n\u00e3o \u00e9 poss\u00edvel deduzir da\u00ed uma garantia geral de d\u00e9bito.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">A ado\u00e7\u00e3o do DPDK justifica-se, sobretudo, quando os benef\u00edcios medidos justificam o esfor\u00e7o adicional de manuten\u00e7\u00e3o. Para contextualizar a plataforma de sistema circundante, o artigo acrescenta <a href=\"https:\/\/webhosting.de\/pt\/novidades-do-kernel-linux-6-para-servidores-de-alojamento\/\">Kernel do Linux em servi\u00e7os de alojamento<\/a> O planeamento. No caso dos servi\u00e7os de alojamento habituais, mant\u00e9m tamb\u00e9m o caminho de rede existente como base de compara\u00e7\u00e3o no teste.<\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Fontes e estado atual dos conhecimentos<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Estado da pesquisa: <time datetime=\"2026-10-25\">2026-10-25<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Vers\u00e3o t\u00e9cnica: 25 de outubro de 2026. As informa\u00e7\u00f5es especificamente designadas como \u00abvers\u00e3o funcional est\u00e1vel\u00bb referem-se ao DPDK 26.07.0. As fontes S4 e S5 documentam caracter\u00edsticas fundamentais do sistema e do EAL com base na norma DPDK 25.07; as op\u00e7\u00f5es dependentes da vers\u00e3o devem, por isso, ser verificadas adicionalmente na vers\u00e3o utilizada. As fontes S6 e S12 remetem, no \u00edndice de fontes, para o ramo de documenta\u00e7\u00e3o sem vers\u00e3o e n\u00e3o s\u00e3o consideradas como prova aut\u00f3noma para a DPDK 26.07. S13 cont\u00e9m as informa\u00e7\u00f5es espec\u00edficas da vers\u00e3o 26.07, mas possui tamb\u00e9m, no \u00edndice, um URL de documenta\u00e7\u00e3o sem vers\u00e3o.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides-26.03\/prog_guide\/ethdev\/ethdev.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/core.dpdk.org\/supported\/nics\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides-25.07\/prog_guide\/env_abstraction_layer.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides-26.07\/prog_guide\/mbuf_lib.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides-25.07\/linux_gsg\/sys_reqs.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides\/linux_gsg\/linux_drivers.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.kernel.org\/networking\/af_xdp.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides\/linux_gsg\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides\/testpmd_app_ug\/testpmd_funcs.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/doc.dpdk.org\/guides\/rel_notes\/release_26_07.html<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>O DPDK processa pacotes para determinadas NICs diretamente no espa\u00e7o do utilizador. O artigo explica o polling, o planeamento de filas e NUMA, a liga\u00e7\u00e3o segura a dispositivos, bem como a diferen\u00e7a em rela\u00e7\u00e3o ao AF_XDP e \u00e0 pilha do kernel do Linux.<\/p>","protected":false},"author":1,"featured_media":21989,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[922],"tags":[],"class_list":["post-21968","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technologie"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts\/21968","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/comments?post=21968"}],"version-history":[{"count":9,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts\/21968\/revisions"}],"predecessor-version":[{"id":21992,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/posts\/21968\/revisions\/21992"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/media\/21989"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/media?parent=21968"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/categories?post=21968"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/pt\/wp-json\/wp\/v2\/tags?post=21968"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}