{"id":21959,"date":"2026-11-03T08:00:00","date_gmt":"2026-11-03T07:00:00","guid":{"rendered":"https:\/\/webhosting.de\/?p=21959"},"modified":"2026-10-30T12:49:30","modified_gmt":"2026-10-30T11:49:30","slug":"100-gbit-naetverk-datacenter-teknik-planering","status":"publish","type":"post","link":"https:\/\/webhosting.de\/sv\/100-gbit-netzwerke-rechenzentrum-technik-planung\/","title":{"rendered":"100-Gbit-n\u00e4tverk i datacentret: Teknik, optik och planering"},"content":{"rendered":"<div class=\"wh-article\" data-wh-layout=\"2.1.2\" style=\"width:100%;max-width:820px;margin:0 auto;color:#263b4b;font-family:inherit;font-size:18px;line-height:1.8;text-align:start;overflow-wrap:break-word;box-sizing:border-box\"><p class=\"wh-lead\" style=\"font-size:20px;line-height:1.7;color:#233746;margin:0 0 1.1em\">En <strong style=\"font-weight:700;color:inherit\">100GbE-n\u00e4tverk<\/strong> \u00e4r l\u00e4mpligt n\u00e4r v\u00e4rdt\u00e4theten, \u00f6st-v\u00e4st-trafiken och uppl\u00e4nksbehovet faktiskt kr\u00e4ver den kapaciteten. Det avg\u00f6rande \u00e4r inte QSFP28-kontakten, utan hela v\u00e4gen fr\u00e5n portprofil, PHY, fiber, r\u00e4ckvidd, FEC och plattformsgodk\u00e4nnande. Olika varianter g\u00e4ller f\u00f6r korta MMF-str\u00e4ckor, duplex-SMF i datacentret och l\u00e4ngre str\u00e4ckor p\u00e5 campus. Ta dessutom h\u00e4nsyn till \u00f6verbokning, redundans och prestandan hos servrar och lagringsutrustning, ist\u00e4llet f\u00f6r att betrakta 100 Gbit\/s som en garanterad applikationsgenomstr\u00f6mning.   <\/p>\n<nav class=\"wh-toc\" aria-label=\"Inneh\u00e5ll i denna artikel\" style=\"display:block;margin:28px 0 38px;padding:22px;border:1px solid #d9e4e8;border-radius:14px;background:#f4f8f8\"><p class=\"wh-toc-title\" style=\"font-size:13px;font-weight:700;letter-spacing:.08em;color:#49656b;margin:0 0 14px\">G\u00e5 direkt till avsnittet<\/p><div class=\"wh-toc-grid\" style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(min(100%,280px),1fr));gap:10px\"><div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#hundertg-eth-grundlagen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Att s\u00e4tta 100GbE i sitt r\u00e4tta sammanhang<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#lanes-phys-und-fec\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Kanaler, PHY-enheter och felkorrigering<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#leaf-spine-kapazitaet\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">100G i Leaf-Spine-n\u00e4tverket<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#optiken-und-kabel-vergleichen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">J\u00e4mf\u00f6r 100G-optik och kablar<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#uplinks-dimensionieren\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Planera uppl\u00e4nkar med kapacitetsber\u00e4kning<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#migration-auf-duplex-smf\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Migrering fr\u00e5n MPO till duplex-SMF<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#abnahme-und-monitoring\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Godk\u00e4nnande, telemetri och drift<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#stoerungen-systematisch-eingrenzen\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Systematiskt avgr\u00e4nsa 100G-st\u00f6rningar<\/a><\/div>\n<div class=\"wh-toc-item\" style=\"display:block;min-width:0;margin:0;padding:0\"><a class=\"wh-toc-link\" href=\"#roce-und-ausbauentscheidung\" style=\"display:block;height:100%;padding:12px 15px;border:1px solid #dce6e8;border-radius:9px;background:#fff;color:#18575b;font-size:14px;line-height:1.5;font-weight:600;text-decoration:none;box-sizing:border-box\">Utv\u00e4rdera RoCE och beslut om utbyggnad<\/a><\/div>\n<\/div><\/nav><section class=\"wh-section\" aria-labelledby=\"hundertg-eth-grundlagen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"hundertg-eth-grundlagen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Att s\u00e4tta 100GbE i sitt r\u00e4tta sammanhang<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">100GbE avser i f\u00f6rsta hand en Ethernet-porthastighet p\u00e5 nominellt 100 Gbit\/s p\u00e5 MAC-niv\u00e5. Detta inneb\u00e4r varken en viss kontakttyp eller en fastst\u00e4lld fibertyp, lane-f\u00f6rdelning eller \u00f6verf\u00f6ringsavst\u00e5nd. I Ethernet-roadmappen placeras 100GbE vid sidan av 25, 50, 200, 400 och h\u00f6gre datahastigheter; vilken niv\u00e5 som \u00e4r l\u00e4mplig beror p\u00e5 trafikprofilen, portt\u00e4theten och utbyggnadsm\u00e5let.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Den nominella portkapaciteten ska inte likst\u00e4llas med en applikations genomstr\u00f6mning. \u00d6verhuvud f\u00f6r Ethernet-, IP- och transportprotokoll minskar den tillg\u00e4ngliga nyttolasten; dessutom kan CPU, n\u00e4tverkskortdrivrutiner, PCIe-anslutning, minnes- eller lagringsprestanda samt motparten utg\u00f6ra begr\u00e4nsande faktorer. \u00c4ven konkurrerande datastr\u00f6mmar delar p\u00e5 portens kapacitet. <strong style=\"font-weight:700;color:inherit\">100 Gbit\/s<\/strong> \u00e4r d\u00e4rf\u00f6r en egenskap hos gr\u00e4nssnittet och inte n\u00e5gon garanti f\u00f6r data\u00f6verf\u00f6ring i en enskild applikation.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En server med ett 100GbE-n\u00e4tverkskort kan till exempel, vid kopiering av stora datam\u00e4ngder, ligga betydligt under portens hastighet om k\u00e4llan eller m\u00e5let inte l\u00e4ser eller skriver tillr\u00e4ckligt snabbt. Omv\u00e4nt \u00f6kar en 100G-uplink den sammanlagda kapaciteten f\u00f6r en serverpod utan att automatiskt \u00f6ka hastigheten f\u00f6r varje enskild v\u00e4rd till 100 Gbit\/s. Vid planeringen m\u00e5ste d\u00e4rf\u00f6r slutsystem, datav\u00e4gar och belastningstoppar beaktas tillsammans.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">100GbE \u00e4r inte generellt sett f\u00f6r litet eller f\u00f6r stort. 25GbE kan r\u00e4cka f\u00f6r allm\u00e4nna serveranslutningar, medan 50GbE utg\u00f6r ett mellansteg f\u00f6r h\u00f6gre v\u00e4rdt\u00e4thet. Beroende p\u00e5 utformningen l\u00e4mpar sig 100GbE f\u00f6r servrar, lagring, leaf-uplinks eller mindre spine-niv\u00e5er. Vid starkt aggregerade arbetsbelastningar kan 200 eller 400GbE tillhandah\u00e5lla den n\u00f6dv\u00e4ndiga portt\u00e4theten. Publicerade IEEE-rapporter t\u00e4cker flera Ethernet-hastigheter och PHY-varianter; hastigheten i sig beskriver dock inte en fullst\u00e4ndig n\u00e4tverksarkitektur.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"lanes-phys-und-fec\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"lanes-phys-und-fec\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Kanaler, PHY-enheter och felkorrigering<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">F\u00f6r att kunna fatta v\u00e4lgrundade beslut m\u00e5ste tre niv\u00e5er granskas separat: de elektriska banorna i enheten, den optiska PHY-enheten p\u00e5 ledningen och den passiva infrastrukturen best\u00e5ende av kablar, fiberoptik och patchpaneler. En 100GbE-port kan anv\u00e4nda flera banor internt eller vid det elektriska v\u00e4rdgr\u00e4nssnittet. \u00c4ldre, fortfarande vanliga l\u00f6sningar bunter ofta ihop fyra 25 Gbit\/s-banor; nyare gr\u00e4nssnitt specificerar elektriska banor upp till 100 Gbit\/s.  <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Antalet banor s\u00e4ger inte n\u00f6dv\u00e4ndigtvis n\u00e5got om hur en optisk modul \u00f6verf\u00f6r data. En PHY kan anv\u00e4nda parallella optiska banor eller \u00f6verf\u00f6ra 100 Gbit\/s via en v\u00e5gl\u00e4ngd. Detta medf\u00f6r olika krav p\u00e5 fibertyp, kontaktdon och patchkablar. En l\u00e4mplig datahastighet och samma formfaktor r\u00e4cker d\u00e4rf\u00f6r inte som bevis p\u00e5 kompatibilitet: switch, n\u00e4tverkskort och transceiver m\u00e5ste st\u00f6dja just den specifika PHY-varianten.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Die <strong style=\"font-weight:700;color:inherit\">Felkorrigering<\/strong> Forward Error Correction (FEC) \u00e4r en funktion som m\u00e5ste kontrolleras utifr\u00e5n PHY- och plattformsdokumentationen vid val och idrifttagning av en specifik 100G-anslutning. En allm\u00e4n giltig FEC-inst\u00e4llning kan inte h\u00e4rledas enbart utifr\u00e5n porthastigheten eller modulens formfaktor. Avg\u00f6rande \u00e4r specifikationerna och de driftsl\u00e4gen som st\u00f6ds av enheterna och s\u00e4ndtagarna i b\u00e5da \u00e4ndarna.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Formfaktorn QSFP28 beskriver fr\u00e4mst konstruktionsformen och familjen av elektriska gr\u00e4nssnitt, men inte n\u00e5gon universell utbytbarhet mellan optiska enheter eller breakout-kablar. En breakout-kabel f\u00f6ruts\u00e4tter att portl\u00e4get, lane-f\u00f6rdelningen, motpartens profil och kabeldragningen \u00e4r anpassade f\u00f6r detta. Innan ink\u00f6p och migrering sker m\u00e5ste d\u00e4rf\u00f6r godk\u00e4nnanden fr\u00e5n respektive switch- och NIC-tillverkare f\u00f6r modul, kabel, PHY, FEC och breakout-l\u00e4ge j\u00e4mf\u00f6ras p\u00e5 ett bindande s\u00e4tt. IEEE 802.3ck behandlar elektriska gr\u00e4nssnitt upp till 100 Gbit\/s per lane, men ers\u00e4tter inte en s\u00e5dan plattformskontroll.  <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"leaf-spine-kapazitaet\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"leaf-spine-kapazitaet\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">100G i Leaf-Spine-n\u00e4tverket<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">I en routad <strong style=\"font-weight:700;color:inherit\">Leaf-Spine-n\u00e4tverket<\/strong> Servrar, lagringssystem och andra slutpunkter ansluts f\u00f6rst till leaf-switchar. Varje leaf \u00e4r ansluten till spine-switchar via flera likv\u00e4rdiga Layer 3-anslutningar. Datatrafiken mellan tv\u00e5 servrar i olika leaf-omr\u00e5den g\u00e5r d\u00e4rmed fr\u00e5n k\u00e4ll-leaven via en spine till m\u00e5l-leaven, ist\u00e4llet f\u00f6r att beh\u00f6va passera genom ett centralt Layer 2-n\u00e4tverk.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Denna struktur \u00e4r utformad f\u00f6r \u00f6st-v\u00e4st-trafik, det vill s\u00e4ga kommunikation inom datacentret mellan applikationer, databaser, lagringsenheter och ber\u00e4kningsnoder. Layer 3-underlaget tillhandah\u00e5ller flera likv\u00e4rdiga v\u00e4gar. ECMP (Equal-Cost Multi-Path) kan f\u00f6rdela datafl\u00f6den p\u00e5 dessa v\u00e4gar med hj\u00e4lp av en hash-algoritm. P\u00e5 s\u00e5 s\u00e4tt kan den aggregerade bandbredden utnyttjas; huruvida det fortfarande finns tillr\u00e4cklig kapacitet kvar efter ett uppl\u00e4nksavbrott \u00e4r dock en fr\u00e5ga om den konkreta dimensioneringen.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">100GbE:s roll f\u00f6ljer i detta sammanhang portprofilen. En t\u00e4tt packad ber\u00e4knings- eller lagringsserver kan beh\u00f6va 100GbE p\u00e5 v\u00e4rden; i en annan pod aggregerar 100G-portar flera 25G-servrar som leaf-uplinks. P\u00e5 samma s\u00e4tt kan 100G-l\u00e4nkar utg\u00f6ra spine-niv\u00e5n i en mindre design. Avg\u00f6rande \u00e4r f\u00f6rh\u00e5llandet mellan ansluten v\u00e4rdkapacitet och uppl\u00e4nkskapacitet, det vill s\u00e4ga den medvetet planerade <strong style=\"font-weight:700;color:inherit\">\u00d6verbokning<\/strong>.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En h\u00f6g total kapacitet p\u00e5skyndar inte ett enskilt datafl\u00f6de i obegr\u00e4nsad utstr\u00e4ckning. I m\u00e5nga implementeringar tilldelar ECMP ett fl\u00f6de en viss v\u00e4g, vars hastighet begr\u00e4nsas av den v\u00e4gens bandbredd och av \u00e4ndsystemen. Oj\u00e4mnt f\u00f6rdelade hashv\u00e4rden eller ett f\u00e5tal mycket stora fl\u00f6den kan d\u00e4rf\u00f6r leda till flaskhalsar trots ledig kapacitet p\u00e5 andra l\u00e4nkar. Kapacitetsplaneringen m\u00e5ste d\u00e4rf\u00f6r ta h\u00e4nsyn till b\u00e5de summan av alla fl\u00f6den och dominerande enskilda fl\u00f6den samt felfall.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"optiken-und-kabel-vergleichen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"optiken-und-kabel-vergleichen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">J\u00e4mf\u00f6r 100G-optik och kablar<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Valet av en 100G-anslutning b\u00f6rjar inte med QSFP28-h\u00f6ljet, utan med hela \u00f6verf\u00f6ringsv\u00e4gen. En s\u00e4ndtagare definierar en viss PHY med krav p\u00e5 fiber, optiska v\u00e4gar och r\u00e4ckvidd. Samma formfaktor kan d\u00e4rf\u00f6r rymma olika tekniker som varken optiskt eller elektriskt automatiskt passar ihop med varandra. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">F\u00f6r korta parallella anslutningar anv\u00e4nds <strong style=\"font-weight:700;color:inherit\">100GBASE-SR4<\/strong> Multimodefiber och vanligtvis MPO-12\/MTP-12-kontakter. De fyra optiska s\u00e4ndnings- och mottagningsv\u00e4garna g\u00f6r att korrekt polaritet m\u00e5ste beaktas redan i planeringsfasen. OM3 \u00e4r specificerad f\u00f6r upp till 70 m och OM4 f\u00f6r upp till 100 m; befintliga duplex-LC-ledningar kan d\u00e4rf\u00f6r inte anv\u00e4ndas som SR4-str\u00e4ckor utan l\u00e4mplig infrastruktur. <\/p>\n<div class=\"wh-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Ett urval av vanliga 100G-\u00f6verf\u00f6ringsalternativ och deras konsekvenser f\u00f6r infrastrukturen\" style=\"width:100%;max-width:100%;overflow-x:auto;margin:28px 0;border:1px solid #dce5e9;border-radius:14px;background:#fff;box-shadow:0 10px 28px -16px rgba(24,47,60,.32);box-sizing:border-box\"><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><caption style=\"padding:20px;text-align:start;font-size:17px;line-height:1.5;font-weight:700;color:#173246;background:#fff\">Ett urval av vanliga 100G-\u00f6verf\u00f6ringsalternativ och deras konsekvenser f\u00f6r infrastrukturen<\/caption><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">PHY<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Fibertyp<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Modulanslutning: kontrollera den konkreta utformningen<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Typisk standardiserad r\u00e4ckvidd<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Konsekvenser f\u00f6r infrastrukturen<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Kompatibilitetsrisk<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">100GBASE-SR4<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">MMF, OM3\/OM4<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">MPO-12\/MTP-12<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">70 m p\u00e5 OM3, 100 m p\u00e5 OM4<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Parallell optik; planera polaritet och MPO-patchv\u00e4g<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Kontrollera MPO-polaritet, fiberklass och st\u00f6d f\u00f6r PHY<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">100GBASE-DR1<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">SMF<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Duplex-LC f\u00f6r de dokumenterade Juniper-modulerna; beroende p\u00e5 produkt<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">500 m<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Duplex-SMF ist\u00e4llet f\u00f6r parallell MPO-kabeldragning<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Plattformen, optiken och motstationen m\u00e5ste st\u00f6dja DR1<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">100GBASE-FR1<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">SMF<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Duplex-LC f\u00f6r de dokumenterade Juniper-modulerna; beroende p\u00e5 produkt<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">2 km<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">F\u00f6r l\u00e4ngre str\u00e4ckor inomhus eller p\u00e5 campus med duplex-SMF<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Kontrollera den optiska budgeten och det uttryckliga FR1-godk\u00e4nnandet<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">100GBASE-LR1<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">SMF<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Duplex-LC f\u00f6r de dokumenterade Juniper-modulerna; beroende p\u00e5 produkt<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">10 km<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">L\u00e5nga SMF-str\u00e4ckor; d\u00e4mpningsbudgeten \u00e4r fortfarande avg\u00f6rande<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Ska inte likst\u00e4llas med LR4; kontrollera PHY-st\u00f6d<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">100GBASE-LR4<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">SMF<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Beroende p\u00e5 produkt; t.ex. Duplex-SC f\u00f6r Cisco CPAK-100GBASE-LR4<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">10 km<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">\u00d6verf\u00f6ring med flera v\u00e5gl\u00e4ngder via duplex-SMF<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Annan PHY \u00e4n LR1 trots liknande r\u00e4ckvidd<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">DAC\/AOC<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Koppar respektive aktiv optisk ledning<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Beroende p\u00e5 tillverkare och port<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Beroende p\u00e5 tillverkare<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">F\u00f6r korta, specifikt godk\u00e4nda anslutningar<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Kontrollera l\u00e4ngd, b\u00f6jningsradie, effektf\u00f6rbrukning och kodning<\/td><\/tr><\/tbody><\/table><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">De dokumenterade Juniper-modulerna f\u00f6r DR1, FR1 och LR1 anv\u00e4nder singlemode-fiber och duplex-LC; de angivna r\u00e4ckvidderna \u00e4r 500 m, 2 km och 10 km. Modulkontakten \u00e4r dock en konkret produktegenskap och f\u00f6ljer tillverkarens dokumentation. PHY, optiskt medium, antal fibrer och modulanslutning ska kontrolleras separat. Kontaktytor, kopplingar, skarvningar och reserver ska dessutom ing\u00e5 i d\u00e4mpningsbalansen. <\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail1\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/100g-lc-mpo-patchfeld-4673492e-detail1-e67a7619d0-1024x683.webp\" class=\"wp-image-21984\" alt=\"Separata multimode-MPO- och singlemode-duplex-LC-patchpaneler i teknikrummet.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/100g-lc-mpo-patchfeld-4673492e-detail1-e67a7619d0-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/100g-lc-mpo-patchfeld-4673492e-detail1-e67a7619d0-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/100g-lc-mpo-patchfeld-4673492e-detail1-e67a7619d0-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/100g-lc-mpo-patchfeld-4673492e-detail1-e67a7619d0-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/100g-lc-mpo-patchfeld-4673492e-detail1-e67a7619d0.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail1\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-genererad symbolbild: Separata fiberbanor och kontaktdon visar olika kabeldragningsinfrastrukturer.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Beteckningen LR kr\u00e4ver s\u00e4rskild noggrannhet: <strong style=\"font-weight:700;color:inherit\">LR1 och LR4<\/strong> De n\u00e5r visserligen upp till 10 km vardera via singlemode-fiber, men \u00e4r olika PHY-standarder. LR1 arbetar med en enda 100 Gbit\/s-v\u00e5gl\u00e4ngd, medan LR4 anv\u00e4nder en annan metod med flera v\u00e5gl\u00e4ngder. Samma infrastruktur med tv\u00e5 enfiberskablar (SMF) och mekaniskt kompatibla produktvarianter garanterar d\u00e4rf\u00f6r inte optisk interoperabilitet. \u00c4ven den konkreta modulanslutningen \u00e4r produktberoende; den dokumenterade Cisco CPAK 100GBASE LR4-varianten anv\u00e4nder till exempel duplex-SC. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">DAC:er och AOC:er \u00e4r ett s\u00e4rskilt val f\u00f6r korta str\u00e4ckor. F\u00f6r passiva eller aktiva kopparkablar och aktiva optiska kablar finns det ingen allm\u00e4ngiltig regel f\u00f6r r\u00e4ckvidd som kan h\u00e4rledas fr\u00e5n \u201e100G\u201c. Innan ink\u00f6p g\u00f6rs m\u00e5ste kompatibilitetsmatrisen f\u00f6r b\u00e5da portarna samt den konkreta kabell\u00e4ngden och den avsedda b\u00f6jningsradien kontrolleras. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"uplinks-dimensionieren\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"uplinks-dimensionieren\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Planera uppl\u00e4nkar med kapacitetsber\u00e4kning<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">F\u00f6ljande illustrativa ber\u00e4knings exempel beskriver uttryckligen en single-homing-konstruktion: 48 v\u00e4rddatorer har vardera totalt en 25 GbE-anslutning. 24 v\u00e4rddatorer vardera \u00e4r anslutna till exakt en av tv\u00e5 leaf-enheter. Detta ger en ansluten v\u00e4rdkapacitet p\u00e5 600 Gbit\/s per leaf-enhet och 1 200 Gbit\/s i hela poden. Det r\u00f6r sig om en kapacitetsber\u00e4kning, inte om uppm\u00e4tt applikationsgenomstr\u00f6mning.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Varje Leaf f\u00e5r tv\u00e5 uppl\u00e4nkar p\u00e5 vardera 100 Gbit\/s. Uppl\u00e4nkskapaciteten uppg\u00e5r d\u00e4rmed till 200 Gbit\/s per Leaf och 400 Gbit\/s f\u00f6r b\u00e5da Leafs. F\u00f6r varje Leaf ger 600 dividerat med 200 en antagen \u00f6verbokning p\u00e5 3:1. Denna summa beskriver den installerade l\u00e4nkkapaciteten; den anv\u00e4ndbara genomstr\u00f6mningen beror dessutom p\u00e5 datastr\u00f6mmar, motparter och protokoll.<\/p>\n<figure class=\"wh-chart\"><figcaption class=\"wh-chart-title\" style=\"display:block;margin:0 0 12px;padding:0;border:0;background:transparent;color:#233c4c;font-size:18px;line-height:1.5;font-weight:700\">Illustrativt r\u00e4kneexempel: Single-homing med 48 v\u00e4rdar<\/figcaption><p class=\"wh-chart-unit\" style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Gbit\/s<\/p><div class=\"wh-chart-bars\"><div class=\"wh-chart-row\"><span class=\"wh-chart-label\">Anslutning till v\u00e4rd, 48 \u00d7 25 GbE<\/span><span class=\"wh-chart-track\" aria-hidden=\"true\"><span class=\"wh-chart-bar\" style=\"width:100.0000%\"><\/span><\/span><span class=\"wh-chart-number\">1200<\/span><\/div><div class=\"wh-chart-row\"><span class=\"wh-chart-label\">Uplink-kapacitet vid 3:1<\/span><span class=\"wh-chart-track\" aria-hidden=\"true\"><span class=\"wh-chart-bar\" style=\"width:33.3333%\"><\/span><\/span><span class=\"wh-chart-number\">400<\/span><\/div><\/div><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Illustrativt r\u00e4kneexempel, ingen m\u00e4tning. 48 v\u00e4rddatorer har vardera en 25G-port; 24 v\u00e4rddatorer \u00e4r anslutna till var och en av de tv\u00e5 Leaf-enheterna. Per Leaf blir det 600 Gbit\/s i v\u00e4rdanslutning och med tv\u00e5 100G-uplinkar 200 Gbit\/s i uplinkkapacitet, allts\u00e5 3:1. F\u00f6r b\u00e5da leaf-enheterna tillsammans: 1 200 mot 400 Gbit\/s. Vid fel p\u00e5 en uppl\u00e4nk \u00e5terst\u00e5r 100 Gbit\/s p\u00e5 den drabbade leaf-enheten, allts\u00e5 6:1; vid fel p\u00e5 en leaf-enhet f\u00f6rlorar dess 24 v\u00e4rddatorer sin anslutning. Detta \u00e4r ingen dual-homing-konstruktion.<\/p><details><summary>Datatabell till diagrammet<\/summary><table style=\"width:100%;min-width:580px;border-collapse:separate;border-spacing:0;border:0;margin:0;font-size:15px;line-height:1.6;background:#fff\"><thead><tr><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Ing\u00e5ng<\/th><th scope=\"col\" style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#19394d;color:#fff\">Gbit\/s<\/th><\/tr><\/thead><tbody><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">Anslutning till v\u00e4rd, 48 \u00d7 25 GbE<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#fff;color:#294252\">1200<\/td><\/tr><tr><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">Uplink-kapacitet vid 3:1<\/td><td style=\"padding:15px 18px;border:0;border-bottom:1px solid #e2e9ed;text-align:start;vertical-align:top;white-space:normal;font-size:15px;line-height:1.6;background:#f4f7f9;color:#294252\">400<\/td><\/tr><\/tbody><\/table><\/details><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Om en enskild uppl\u00e4nk slutar fungera \u00e5terst\u00e5r 100 Gbit\/s p\u00e5 den drabbade leaf-enheten f\u00f6r dess 600 Gbit\/s v\u00e4rdanslutningar. Det ber\u00e4knade f\u00f6rh\u00e5llandet stiger d\u00e4r till 6:1. Om en hel leaf slutar fungera blir dess 24 v\u00e4rdar o\u00e5tkomliga i denna medvetet icke-redundanta v\u00e4rdanslutningsmodell. Tv\u00e5 leafar r\u00e4cker d\u00e4rf\u00f6r inte i sig f\u00f6r att s\u00e4kerst\u00e4lla en fel s\u00e4ker anslutning f\u00f6r varje server.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">En dual-homing-konfiguration m\u00e5ste ber\u00e4knas separat. Med 48 v\u00e4rddatorer som vardera har tv\u00e5 25G-anslutningar \u00e4r den fysiska anslutningskapaciteten 2 400 Gbit\/s. Om b\u00e5da anslutningarna hanterar trafik samtidigt eller om en fungerar som reserv p\u00e5verkar detta belastningsantagandena. Dokumentera d\u00e4rf\u00f6r antalet anslutningar, den aktiva driftsmodellen, kapaciteten per leaf och \u00f6nskad restkapacitet f\u00f6r varje t\u00e4nkbart avbrottsscenario.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">\u00c4ven trafikf\u00f6rdelningen ing\u00e5r i planeringen. ECMP f\u00f6rdelar fl\u00f6den \u00f6ver likv\u00e4rdiga routade v\u00e4gar; l\u00e4nkaggregering sammanf\u00f6r fysiska l\u00e4nkar till en logisk anslutning. B\u00e5da metoderna m\u00e5ste utv\u00e4rderas separat. Vid hashbaserad f\u00f6rdelning tilldelas inte ett enskilt fl\u00f6de automatiskt hela den sammanlagda bandbredden. Planera f\u00f6r dominerande datastr\u00f6mmar, s\u00e4kerhetskopieringsf\u00f6nster och reserver ut\u00f6ver det ber\u00e4knade f\u00f6rh\u00e5llandet.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"migration-auf-duplex-smf\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"migration-auf-duplex-smf\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Migrering fr\u00e5n MPO till duplex-SMF<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">\u00d6verg\u00e5ngen fr\u00e5n en SR4-milj\u00f6 till DR1 eller FR1 \u00e4r ett infrastrukturprojekt, inte en automatisk kvalitetsf\u00f6rb\u00e4ttring. SR4 anv\u00e4nder parallella multimode-v\u00e4gar med MPO-12\/MTP-12. DR1 och FR1 anv\u00e4nder d\u00e4remot duplex-singlemode-fiber; modulens anslutning \u00e4r en produktegenskap. De DR1- och FR1-moduler som dokumenteras i Junipers \u00f6versikt har duplex-LC-anslutningar. Befintliga kabelstr\u00e4ckningar, patchpaneler och reserver avg\u00f6r d\u00e4rf\u00f6r om en parallell migrering eller en stegvis \u00f6verg\u00e5ng \u00e4r mest l\u00e4mplig. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">F\u00f6rst kartl\u00e4ggs det faktiska r\u00e4ckviddsbehovet: DR1 \u00e4r avsett f\u00f6r 500 m, FR1 f\u00f6r 2 km. Om alla v\u00e4gar ligger inom ett utrymme kan en fungerande SR4-kabeldragning fortfarande vara l\u00e4mplig. Om str\u00e4ckorna regelbundet \u00f6verskrider SR4-gr\u00e4nserna eller om byggnadsdelar ska kopplas samman skapar Duplex-SMF med l\u00e4mplig PHY en annan planeringsram. <\/p>\n<ul class=\"wh-list\" role=\"list\" style=\"list-style:none;margin:24px 0;padding:0\"><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Dokumentera befintliga fiberv\u00e4gar, fiberklass, patchpaneler och MPO-polaritet per anslutning.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Fastst\u00e4ll den erforderliga r\u00e4ckvidden och den PHY som passar f\u00f6r detta; v\u00e4lj inte DR1 och FR1 enbart utifr\u00e5n kontakttypen.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Planera duplex-SMF-fiberv\u00e4gar, inklusive produktspecifika modulanslutningar, d\u00e4mpningsreserv, anslutningsytor och redundanta rutter.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Utv\u00e4rdera framtida porthastigheter, tillg\u00e4ngliga kortplatser och tidpunkten f\u00f6r \u00f6verg\u00e5ngen f\u00f6r varje pod.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Kontrollera att switch, n\u00e4tverkskort, s\u00e4ndtagare och eventuella breakout-tillval utg\u00f6r en konkret godk\u00e4nd kombination.<\/li><\/ul><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Die <strong style=\"font-weight:700;color:inherit\">MPO-polaritet<\/strong> b\u00f6r dokumenteras som en separat kontrollpunkt s\u00e5 l\u00e4nge delar av den parallella SR4-kabeldragningen finns kvar. En mekaniskt passande adapter ger inte automatiskt svar p\u00e5 fr\u00e5gor om signaltilldelning, antal fibrer eller till\u00e5ten \u00f6verf\u00f6ringsmetod. Som planeringsrekommendation f\u00f6resl\u00e5s d\u00e4rf\u00f6r en tydlig \u00e5tskillnad och m\u00e4rkning av patchv\u00e4garna: SR4 via MMF \u00e5 ena sidan, DR1 eller FR1 via SMF \u00e5 andra sidan.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Duplex-SMF kan f\u00f6renkla utbyggnadsm\u00f6jligheterna, men \u00e4r inte generellt sett \u201eb\u00e4ttre\u201c. Kostnader f\u00f6r ny kabeldragning, tillg\u00e4ngliga ledningsstr\u00e4ckor, driftsrutiner och den f\u00f6rv\u00e4ntade portutvecklingen \u00e4r lika relevanta som r\u00e4ckvidden. Den tidigare klassificeringen av 100 Gbit\/s-PON avser en strategi f\u00f6r accessn\u00e4t och utg\u00f6r inte n\u00e5gon kompatibilitets- eller arkitekturmall f\u00f6r Ethernet i datacentret; den b\u00f6r d\u00e4rf\u00f6r inte f\u00f6rv\u00e4xlas med 100GbE-PHY:er.<a href=\"https:\/\/webhosting.de\/sv\/passivt-optiskt-naetverk-pon-vodafone-och-nokia-prov-100-gbit-s\/\">100 Gbit\/s-PON i korthet<\/a><\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Innan en ink\u00f6p g\u00f6rs m\u00e5ste man kontrollera den specifika kombinationen av switch, n\u00e4tverkskort och transceiver p\u00e5 b\u00e5da sidor. Vid detta tillf\u00e4lle kontrolleras vilka PHY-standarder som st\u00f6ds, FEC-krav, optisk kodning, modulanslutningar och till\u00e5tna kablar. Det \u00e4r f\u00f6rst efter detta godk\u00e4nnande som den planerade passiva kabeldragningen kan kopplas samman med en aktiv str\u00e4cka som faktiskt st\u00f6ds; ett passande h\u00f6ljesformat r\u00e4cker inte i sig. <\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"abnahme-und-monitoring\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"abnahme-und-monitoring\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Godk\u00e4nnande, telemetri och drift<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Godk\u00e4nnandet av en 100GbE-l\u00e4nk inleds med en \u00f6versk\u00e5dlig inventering, inte med en enskild uppkopplingsh\u00e4ndelse. Dokumentera f\u00f6r varje anslutning hela fiberv\u00e4gen, inklusive str\u00e4ckning, patchpaneler, kopplingar och portbeteckningar. Ange vilken typ av optik som anv\u00e4nds, fiberklass, kontaktdonstyp, nominell r\u00e4ckvidd samt den valda FEC-inst\u00e4llningen p\u00e5 b\u00e5da sidor. Tillverkarnas \u00f6versikter skiljer mellan olika 100G-optiker utifr\u00e5n r\u00e4ckvidd, fiber och \u00f6verf\u00f6ringsmetod; dessa dokumenterade produktspecifikationer m\u00e5ste st\u00e4mma \u00f6verens med den faktiska str\u00e4ckan. <\/p>\n<ul class=\"wh-list\" role=\"list\" style=\"list-style:none;margin:24px 0;padding:0\"><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Kontrollera l\u00e4nkstatus och tilldelning av motstationer i b\u00e5da \u00e4ndarna.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">J\u00e4mf\u00f6r optiktyp, serienummer, fibertyp och dokumenterad kopplingsv\u00e4g.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Registrera FEC-status samt felr\u00e4knare f\u00f6re \u00f6verl\u00e4mning och efter en fastst\u00e4lld \u00f6vervakningstid.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Sp\u00e5ra redundansv\u00e4garna p\u00e5 ett m\u00e5linriktat s\u00e4tt och kontrollera de tillh\u00f6rande larmfunktionerna.<\/li><li style=\"margin:8px 0;padding:12px 17px;background:#f5f8fa;border:1px solid #e0e8ec;border-radius:9px\">Ange kontaktperson vid eskalering, reservlinser och aktuell kompatibilitetsgodk\u00e4nnande f\u00f6r respektive port.<\/li><\/ul><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Den som anges i optikdokumentationen <strong style=\"font-weight:700;color:inherit\">R\u00e4ckvidd<\/strong> beskriver respektive modulvariant och dess avsedda \u00f6verf\u00f6ringsmedium; den utg\u00f6r inte ett generellt godk\u00e4nnande av varje installerad str\u00e4cka.  F\u00f6r godk\u00e4nnandet rekommenderas d\u00e4rf\u00f6r dessutom en projektspecifik d\u00e4mpningsbalans. D\u00e4r registreras de faktiskt f\u00f6religgande patchpunkterna, kopplingarna, skarvarna och de avsedda reserverna. Rena anslutningsytor och en fullst\u00e4ndig dokumentation av installationsf\u00f6rloppet \u00e4r ocks\u00e5 driftsm\u00e4ssiga kontrollkrav och b\u00f6r uttryckligen fastst\u00e4llas i godk\u00e4nnandeplanen.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Under drift b\u00f6r \u00f6vervakningssystem registrera link-flaps, FEC-korrigerade och icke-korrigerbara fel, symbol- eller PCS-fel, optiska diagnostikv\u00e4rden samt belastningen per v\u00e4g, i den m\u00e5n plattformen och s\u00e4ndtagaren tillhandah\u00e5ller dessa v\u00e4rden. Ett enskilt m\u00e4tv\u00e4rde \u00e4r i sig inte en diagnos: det avg\u00f6rande \u00e4r trenden, riktningen och den tidsm\u00e4ssiga kopplingen till f\u00f6r\u00e4ndringar i patchning, optik eller konfiguration. Vid avvikelser utreder driftsteamet f\u00f6rst om endast en v\u00e4g, en enhet eller flera likartade anslutningar \u00e4r ber\u00f6rda.<\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">F\u00f6r att uppn\u00e5 redundans r\u00e4cker det inte med att ha tv\u00e5 logiska l\u00e4nkar. Kontrollera om de faktiskt g\u00e5r via separata portar, fiberkablar och \u2013 i den m\u00e5n s\u00e5 \u00e4r avsett \u2013 separata patchv\u00e4gar, samt om larmreglerna rapporterar ett avbrott i tid. Krav p\u00e5 fysisk resiliens och driften av datacentret ing\u00e5r i den \u00f6vergripande planeringen; detta f\u00f6rklaras i artikeln <a href=\"https:\/\/webhosting.de\/standort-sicherheit-und-skalierbarkeit-kriterien-fuer-die-wahl-des-richtigen-rechenzentrums\/\">Kriterier f\u00f6r datacentrets placering, s\u00e4kerhet och skalbarhet<\/a> ytterligare ramvillkor.<\/p>\n<\/section><section class=\"wh-section\" aria-labelledby=\"stoerungen-systematisch-eingrenzen\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"stoerungen-systematisch-eingrenzen\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Systematiskt avgr\u00e4nsa 100G-st\u00f6rningar<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Om en 100G-l\u00e4nk \u00e4r ur funktion eller instabil \u00e4r en fast testsekvens effektivare \u00e4n att omedelbart byta ut flera komponenter. Kontrollera f\u00f6rst den godk\u00e4nda kombinationen av switch eller NIC, transceiver, kabel och PHY samt det f\u00f6rv\u00e4ntade FEC-l\u00e4get f\u00f6r b\u00e5da \u00e4ndarna. Elektriska gr\u00e4nssnitt med 100 Gbit\/s per lane \u00e4r standardiserade, men det inneb\u00e4r inte att en specifik plattform automatiskt st\u00f6der alla varianter av optiska moduler eller breakout-enheter. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">D\u00e4refter f\u00f6ljer den passiva str\u00e4ckan: fibertyp, anslutningsyta, patchv\u00e4g, m\u00e4rkning och, vid parallelloptik, s\u00e4rskilt <strong style=\"font-weight:700;color:inherit\">MPO-polaritet<\/strong> . Felaktig polaritet kan f\u00f6rhindra en l\u00e4nk, medan en f\u00f6rv\u00e4xling mellan OM3 och OM4 p\u00e5verkar den till\u00e5tna planeringsl\u00e4ngden. SR4 kr\u00e4ver multimode- och parallella optiska v\u00e4gar; DR1, FR1 och LR1 fungerar d\u00e4remot via singlemode-duplexstr\u00e4ckor. En kassett som ser likadan ut eller en passande kontakt bevisar d\u00e4rf\u00f6r inte att \u00f6verf\u00f6ringstypen \u00e4r kompatibel. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Vid f\u00f6rh\u00f6jda felfrekvenser ska du j\u00e4mf\u00f6ra felr\u00e4knarna p\u00e5 b\u00e5da sidor och koppla ihop deras starttidpunkt med eventuella \u00e4ndringar. Om v\u00e4rdena endast stiger p\u00e5 en l\u00e4nk \u00e4r optiken, kontaktytorna, patchkabeln och porten uppenbara kontrollpunkter. Om fel uppst\u00e5r p\u00e5 flera anslutningar av samma typ m\u00e5ste gemensamma faktorer s\u00e5som FEC-inst\u00e4llningar, optisk kodning eller en plattformsprofil unders\u00f6kas. Dokumenterade specifikationer f\u00f6r s\u00e4ndtagare hj\u00e4lper till att j\u00e4mf\u00f6ra r\u00e4ckvidd och fiberkrav med n\u00e4tverkskonfigurationen. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Du b\u00f6r f\u00f6rst unders\u00f6ka ov\u00e4ntat l\u00e5ga datahastigheter i applikationer efter att en stabil fysisk l\u00e4nk har uppr\u00e4ttats. Ett enskilt fl\u00f6de kan begr\u00e4nsas av sin v\u00e4ghastighet, ECMP-hashf\u00f6rdelning eller motparten, \u00e4ven om den aggregerade n\u00e4tverksstrukturen har ledig kapacitet. Dessutom begr\u00e4nsar PCIe-anslutningen, NIC-drivrutinerna, CPU:n, paketstorlekarna, protokoll\u00f6verheaden och lagringsprestandan datagenomstr\u00f6mningen. 100GbE-porten \u00e4r d\u00e4rmed en m\u00f6jlig, men inte automatiskt den avg\u00f6rande flaskhalsen.<\/p>\n<aside class=\"wh-callout wh-callout-warning\" style=\"display:block;margin:28px 0;padding:20px 23px;border:1px solid #d1e4dd;border-left:4px solid #187065;border-radius:11px;background:#f0f7f4\"><p class=\"wh-callout-title\" style=\"margin:0 0 8px;color:#1c5c53;font-size:16px;font-weight:700;line-height:1.5\">Kontrollera kompatibiliteten innan du byter ut den<\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Att formfaktorn \u00e4r densamma, till exempel QSFP28, inneb\u00e4r inte att produkterna \u00e4r kompatibla. Ol\u00e4mpliga breakout-kablar, optiska kodningar som inte st\u00f6ds eller avvikande lane-f\u00f6rdelningar kan leda till l\u00e4nkproblem trots att kontakterna passar mekaniskt. Kontrollera d\u00e4rf\u00f6r att b\u00e5da \u00e4ndenheterna \u00e4r godk\u00e4nda innan du byter ut komponenter. <\/p>\n<\/aside><\/section><section class=\"wh-section\" aria-labelledby=\"roce-und-ausbauentscheidung\" style=\"display:block;margin:0 0 36px;min-width:0\"><h2 id=\"roce-und-ausbauentscheidung\" style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">Utv\u00e4rdera RoCE och beslut om utbyggnad<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">N\u00e4r det g\u00e4ller RDMA \u00f6ver Converged Ethernet r\u00e4cker inte porthastigheten som urvalskriterium. Den NVIDIA-k\u00e4lla som anv\u00e4nds h\u00e4r beskriver uttryckligen Cumulus Linux 4.0 och h\u00e4nvisar sj\u00e4lv till nyare produktdokumentation. Den fungerar d\u00e4rf\u00f6r som ett historiskt, produktbundet underlag f\u00f6r de mekanismer som behandlas. Dess kommandon och gr\u00e4nsv\u00e4rden utg\u00f6r inte en allm\u00e4n, aktuell driftsguide f\u00f6r andra plattformar. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Denna dokumentation skiljer RoCEv1 p\u00e5 s\u00e4kerhetslagret fr\u00e5n RoCEv2 p\u00e5 lager 3. F\u00f6r RoCEv1 beskriver den Priority Flow Control (PFC). F\u00f6r RoCEv2 n\u00e4mns Explicit Congestion Notification (ECN) f\u00f6r signalering fr\u00e5n \u00e4nde till \u00e4nde \u00f6ver routade n\u00e4tverk samt fl\u00f6deskontroll f\u00f6r f\u00f6rlustfattigt Ethernet. D\u00e4rifr\u00e5n kan man dock varken h\u00e4rleda en aktuell universell PFC-konfiguration eller \u00f6verf\u00f6rbarheten av de historiska Cumulus Linux 4.0-inst\u00e4llningarna till andra plattformar. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Kontrollera den aktuella dokumentationen f\u00f6r de n\u00e4tverkskort, switchar och programvaruversioner som anv\u00e4nds inf\u00f6r en konkret utbyggnad. Vilken RoCE-version \u00e4r avsedd, vilka trafikklasser anv\u00e4nds och vilka \u00f6verbelastningskontrollmekanismer st\u00f6ds av denna kombination? Fastst\u00e4ll dessutom hur k\u00f6bel\u00e4ggning, paketf\u00f6rluster, ECN-markeringar och PFC-pauser ska \u00f6vervakas. Anv\u00e4nd inte historiska tr\u00f6skelv\u00e4rden eller globala aktiveringsrekommendationer utan plattformsspecifik validering.<\/p>\n<figure class=\"wp-block-image size-large wh-figure\" aria-describedby=\"wh-caption-detail2\" style=\"display:block;float:none;clear:both;width:100%;max-width:760px;margin:34px auto 40px;border:1px solid #dae5e9;border-radius:14px;overflow:hidden;background:#f5f8fa;box-shadow:0 10px 28px -17px rgba(24,47,60,.28);box-sizing:border-box\"><div class=\"wh-figure-media\" style=\"display:block;background:#eef3f5;line-height:0\"><img loading=\"lazy\" width=\"800\" height=\"534\" src=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/roce-kapazitaet-betriebsplanung-4673492e-detail2-31aec36d66-1024x683.webp\" class=\"wp-image-21985\" alt=\"Tv\u00e5 experter diskuterar n\u00e4tkapacitet och redundans utifr\u00e5n ett utskrivet schema.\" decoding=\"async\" srcset=\"https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/roce-kapazitaet-betriebsplanung-4673492e-detail2-31aec36d66-1024x683.webp 1024w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/roce-kapazitaet-betriebsplanung-4673492e-detail2-31aec36d66-300x200.webp 300w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/roce-kapazitaet-betriebsplanung-4673492e-detail2-31aec36d66-768x512.webp 768w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/roce-kapazitaet-betriebsplanung-4673492e-detail2-31aec36d66-18x12.webp 18w, https:\/\/webhosting.de\/wp-content\/uploads\/2026\/10\/roce-kapazitaet-betriebsplanung-4673492e-detail2-31aec36d66.webp 1536w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" ><\/div><figcaption class=\"wh-caption\" id=\"wh-caption-detail2\" style=\"display:block;margin:0;padding:12px 18px 15px;border-top:1px solid #dce5e9;color:#506575;background:#f5f8fa;font-size:14px;line-height:1.55;text-align:start\">AI-genererad illustrativ bild: F\u00f6r RoCE och h\u00f6ga belastningar m\u00e5ste kapacitet, QoS och drift planeras gemensamt.<\/figcaption><\/figure><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Valet mellan 25, 50, 100, 200 eller 400 GbE beror p\u00e5 belastningsprofilen, anslutningen till v\u00e4rddatorn och den n\u00f6dv\u00e4ndiga reservkapaciteten vid eventuella avbrott. Ethernet-roadmappen visar tekniska utvecklingsriktningar, d\u00e4ribland 100G\u2013800G-anslutningar och det framv\u00e4xande 1,6 Tbit\/s-Ethernet. Den fastst\u00e4ller dock varken en specifik leaf-spine-arkitektur eller vilken hastighet som \u00e4r l\u00e4mplig f\u00f6r varje serverklass. D\u00e4rf\u00f6r kr\u00e4vs fortfarande en separat kapacitetsplanering. <\/p>\n<p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">G\u00f6r slutligen \u00e5tskillnad mellan publicerade standarder, p\u00e5g\u00e5ende projekt och konkret tillg\u00e4ngliga produktfunktioner. IEEE f\u00f6r i nul\u00e4get P802.3dj som ett aktivt projekt f\u00f6r 200, 400 och 800 Gbit\/s samt 1,6 Tbit\/s. Detta inneb\u00e4r dock inget l\u00f6fte om kompatibilitet med befintlig h\u00e5rdvara. Kontrollera f\u00f6r varje utbyggnadsv\u00e4g porttillg\u00e4nglighet, optik, fiberv\u00e4gar, str\u00f6mf\u00f6rbrukning och driftskostnader utifr\u00e5n de faktiskt valda produkterna. <\/p>\n<\/section><section class=\"wh-sources\" style=\"margin:40px 0 0;padding:24px 0 0;border-top:1px solid #dce5e9;color:#596b7b;font-size:14px;line-height:1.65\"><h2 style=\"margin:38px 0 18px;color:#172f41;font-size:clamp(24px,1.25rem + 1vw,30px);font-weight:700;line-height:1.3;scroll-margin-top:115px\">K\u00e4llor och aktuell kunskapsniv\u00e5<\/h2><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Forskningsl\u00e4get: <time datetime=\"2026-10-23\">2026-10-23<\/time><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\">Forskningsl\u00e4get: 23 oktober 2026. Artikeln skiljer mellan publicerade IEEE-standarder och tillverkardokumentation \u00e5 ena sidan och p\u00e5g\u00e5ende standardiseringsarbete, s\u00e4rskilt P802.3dj, \u00e5 andra sidan.<\/p><div class=\"wh-source-urls\"><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/ethernetalliance.org\/technology\/ethernet-roadmap\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.juniper.net\/documentation\/us\/en\/hardware\/100g-optics-cables-guide\/optics\/topics\/concept\/100g-transceiver-technologies.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.ieee802.org\/3\/archive.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.ieee802.org\/3\/ck\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.cisco.com\/c\/de_de\/td\/docs\/iosxr\/asr9000\/hardware-install\/ethernet-line-card-installation-guide\/b-asr9k-ethernt-line-card-install-guide\/b-asr9k-ethernt-line-card-install-guide_chapter_01.html<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.juniper.net\/documentation\/us\/en\/hardware\/100g-optics-cables-guide\/100g-optics-cables-guide.pdf<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/docs.nvidia.com\/networking-ethernet-software\/cumulus-linux-40\/Network-Solutions\/RDMA-over-Converged-Ethernet-RoCE\/<\/span><\/p><p style=\"margin:0 0 1.1em;font-size:inherit;line-height:inherit\"><span class=\"wh-source-url\" data-no-translation dir=\"ltr\" style=\"overflow-wrap:anywhere;font:12px\/1.6 ui-monospace,monospace;direction:ltr\">https:\/\/www.ieee802.org\/3\/<\/span><\/p><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>100GbE \u00e4r inte en enskild teknik, utan en Ethernet-hastighet med olika PHY-enheter, fibertyper och migrationsv\u00e4gar. Denna guide ger en \u00f6versikt \u00f6ver arkitektur, optik, kapacitetsplanering och drift.<\/p>","protected":false},"author":1,"featured_media":21983,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"categories":[922],"tags":[],"class_list":["post-21959","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technologie"],"acf":[],"_links":{"self":[{"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/posts\/21959","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/comments?post=21959"}],"version-history":[{"count":5,"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/posts\/21959\/revisions"}],"predecessor-version":[{"id":21986,"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/posts\/21959\/revisions\/21986"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/media\/21983"}],"wp:attachment":[{"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/media?parent=21959"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/categories?post=21959"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/webhosting.de\/sv\/wp-json\/wp\/v2\/tags?post=21959"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}